Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF AUGUST 28, 2001 PSA #2924
SOLICITATIONS

66 -- AUTOMATED EIA PROCESSOR SYSTEM

Notice Date
August 24, 2001
Contracting Office
Olin E. Teague Veterans' Center (90C), Chief Logistics Management Service, 1901 South First St., Temple, TX 76504
ZIP Code
76504
Solicitation Number
674-95-01
Response Due
October 10, 2001
Point of Contact
Sandra Hallmark, 254-771-4575
Description
Central Texas Veterans Health Care System (CTVHCS, Temple, TX intends to procure the MAGO Plus System"Automation Solution Program" from DiaMedix on a sole source basis for the period from date of award through 9/30/02 and four option years. This program includes provision of Catalog#251-100 MAGO Plus Automated EIA Analyzer, #232-110 Epson Printer LQ570, #236-500 Barcode Reader; #233-100N UPS, and #236-100 Mini Keyboard and the following kits: Is-ANA ELISA Screen (37 kits per year); Is-anti-dsDNA (3 kits/year); Is Toxo IgG (5 kits/yr);Is Toxo Capture IgM (5 kits/year), #720-360 IS-Rubella IgC (3 kits per year); #720-320, Is-CMV IgG (4 kits per year); #720-330 IsCMV Caputer IgM (4 kits per year); #720-380 Is-VZV IgG (5 kits per year); #720-520 Is-Measles IgG (3 kits per year); #720-540 Is-Mumps IgG (2 kits per year); #720-390 Is-B. burgdorferi IgG/IgM (8 kits per year); #720-510 Is-B. burgdorferi IgM (8 kits per year); #720-130 Is-H. pylori IgG (55 kits per year); #720-600 Is-EBV VCA lgG (4 kits per year); #720-620 Is-EBNA-1 lgG (5 kits per year); #720-640 Is-EBV-EA-D IgG (4 kits per year); #250-030 Calibration Check Kit (2); #790-915 DRI-DYE 405/450 (2);#251-035 ProbeClean Concentrate (2); #250-040 Black Wells (2/bag) (4); #250-050 MAGO Dilution Cups (12); #250-055 Microtubes with Caps (500/bx) (2). The MAGO Plus is a flexible, automated immunoassay system for autoimmune and infectious diseases. The MAGO plus has the following salient characteristics: 1) The instrument must be capable of simultaneously running up to 9 assays on four 96 well plates simultaneously. The plates must be able to be incubated either at room temperature or 37C without manually manipulating the plates. 2) The instrument must have a dead volume of 4microliters of reagent or sample, 3) All cuvettes used in the performance of assays must be disposable, 4) a fixed probe capable of rinsing and pipetting without disposable tips must be included, 5) The instrument must visually be able to show the number of tests remaining, 6) Training must be accomplished within two days , 7) Service and applications support provided by the same company, 8)Proven record of machine and service reliability. Approximate issue/response date is 10/10/01. Only written or faxed requests received directly from the requestor are acceptable. All responsible sources solicited may submit a bid, proposal, or quoatation which shall be considered. The proposed contract action is for supplies and services for which the Government intends to solicit and negotiate with only one source under the authority of FAR 6.302-1. Interested persons may identify their interest and capability to respond to the requirement or submit proposals. This notice of intent is not a request for competitive proposals. No solicitation document presently exists. However, all proposals received within forty five days after date of publication of this synopsis will be considered by the Government. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. Interested respondents should supply sufficient documentation to demonstrate their capability to meet the above salient characteristics no later than 10/10/01.
Record
Loren Data Corp. 20010828/66SOL007.HTM (W-236 SN50V936)

66 - Instruments and Laboratory Equipment Index  |  Issue Index |
Created on August 24, 2001 by Loren Data Corp. -- info@ld.com