Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF JULY 30, 2001 PSA #2903
SOLICITATIONS

43 -- FILTER ELEMENT

Notice Date
July 26, 2001
Contracting Office
Defense Supply Center Columbus, P.O. Box 16704, DSCC-PLI, Columbus OH 43216-5010
ZIP Code
43216-5010
Solicitation Number
SP0760-01-R-3287
Response Due
September 17, 2001
Point of Contact
For Information Only, Point of Contact -- Tracy Roberts, Telephone Number -- (614) 692-2714
E-Mail Address
Defense Supply Center Buyer (tracy.roberts@dscc.dla.mil)
Description
FILTER ELEMENT, FLUID. PERMANENT-TYPE SEPARATOR. 24 IN. NOM. LENGTH. OUTSIDE TO INSIDE FLOW. PER DCSC DRAWING CS4330-0015 AND APPLICABLE PARAGRAPHS OF MIL-F-15618. EXCEPTION TO DRAWING CS4330-0015: PARA. 4.1.1, LINE 12: DELETE WORDS, "...UNDISSOLVED (FREE) WATER." AND INSERT "...MORE THAN 5 PARTS PER MILLION OF WATER." FIRST ARTICLE TEST, I/A/W DWG. CS4330-0015, PARA 4.1.1, SHALL BE USED IN LIEU OF THE QUALIFIED PRODUCTS LIST, (QPL). "CLASS I OZONE DEPLETING CHEMICALS ARE NOT TO BE USED NOR INCORPORATED IN ANY ITEMS TO BE DELIVERED UNDER THIS CONTRACT. THIS PROHIBITION SUPERSEDES ALL SPECIFICATION REQUIREMENTS BUT DOES NOT ALLEVIATE ANY PRODUCT REQUIREMENTS. SUBSTITUTE CHEMICALS MUST BE SUBMITTED FOR APPROVAL UNLESS THEY ARE AUTHORIZED BY THE SPECIFICATION REQUIREMENTS." IF AQLS ARE LISTED IN THE SPECIFICATION(S) OR DRAWING(S) THEY MAY BE USED TO ESTABLISH THE AUTHORIZED SAMPLE SIZE, HOWEVER, THE ACCEPTANCE NUMBER FOR THIS CONTRACT IS ZERO; I.E., THIS CONTRACT REQUIRES A SAMPLING PLAN THAT ACCEPTS ON ZERO DEFECTS AND REJECTS ON ONE OR MORE DEFECT(S). CERTIFICATE OF QUALITY COMPLIANCE APPLIES -- DLAR 52.246-9000. PRODUCT VERIFICATION TESTING APPLIES -- DLAR 52.246-9004. CONTRACTOR/MANUFACTURER IS REQUIRED TO ESTABLISH AND MAINTAIN A CALIBRATION SYSTEM THAT MEETS THE REQUIREMENTS OF ANSI/NCSL Z540-1-1994, AMERICAN NATIONAL STANDARD FOR CALIBRATION -- CALIBRATION LABORATIORIES AND MEASURING AND TEST EQUIPMENT -- GENERAL REQUIREMENTS, OR ISO 10012-1, QUALITY ASSURANCE REQUIREMENTS FOR MEASURING EQUIPMENT -- PART 1, METROLOGICAL CONFIRMATION SYSTEM FOR MEASUING EQUIPMENT. SUBJECT TO FIRST ARTICLE TESTING AND APPROVAL BY THE NAVY, NYLON HYDROPHOBIC MESH MEDIUM IS ACCEPTABLE I/L/O TEFLON COATED MONEL MESH MEDIUM. I/A/W DRAWING NR 16236 CS4330-0015 BASIC DTD 02/03/83 AMEND NR A DTD 01/25/84 TYPE NUMBER SPECIFICATION I/A/W SPEC NR MIL-F-15618F BASIC DTD 08/31/62 AMEND NR 4 DTD 02/28/85 TYPE NUMBER All responsible sources may submit an offer/quote which shall be considered. Notes 9, 12 and 26 apply. This solicitation is an RFP or IFB and will be available on the Internet at http://dibbs.dscccols.com/Rfp on its issue date of 16 Aug 2001. Hard copies of this solicitation are not available. Drawings are posted with the solicitation on the DSCC solicitation web-site. If the drawings are not posted with the solicitation, see Clause L07 -- Availability of Drawings for information on how to obtain the drawings. FEDERAL, MILITARY AND COMMERCIAL SPECIFICATIONS CANNOT BE PROVIDED BY DSCC. The proposed procurement contains an option to extend the contract period one or more times at the discretion of the government. The total duration (base plus option years) shall not exceed 5 years. This is an unrestricted acquisition. While price may be a significant factor in the evaluation of offers, the final award decision will be based upon a combination of price, delivery, past performance and other evaluation factors as described in the solicitation. Various Increments Solicited: This solicitation is for a long term contract with Indefinite Quantities and is solicited with 4 quantity ranges for quantity break pricing.
Record
Loren Data Corp. 20010730/43SOL001.HTM (W-207 SN50T0E7)

43 - Pumps and Compressors Index  |  Issue Index |
Created on July 26, 2001 by Loren Data Corp. -- info@ld.com