Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF JULY 27, 2001 PSA #2902
SOLICITATIONS

66 -- SMART CYCLER PCR MEASUREMENT DEVICE

Notice Date
July 25, 2001
Contracting Office
U.S. Department of Agriculture, ARS, LPSI, East Side Service Center, Bldg. 307, Room 129, BARC-East, Beltsville, MD 20705
ZIP Code
20705
Solicitation Number
1011265152-00183
Response Due
August 11, 2001
Point of Contact
John C. Wilkinson, Phone (301) 504-5799, Fax (301) 504-8696
Description
This a a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. The solicitation number is 1011265152-00183 and is issued as a Request for Quotation (RFQ) on a full and open competitive basis. This solicitation is unrestricted. This solicitation incorporates provisions and clauses that are in effect through Federal Acquisition Circular 97-27. The Standard Industrial Classification Code is 3823. This product shall be delivered within 60 days after award. Shipping shall be "F.O.B. Destination" with inside delivery to the U.S. Department of Agriculture in Beltsville, Maryland 20705. This procurement is for the following item or equivalent: ("SMART CYCLER", Portable, Rapid, Fluorescent-Tag-Polymerase Chain Reaction FT-RCP Measurement System; Part number: SC1000N2-1, Manufactured by: Cepheid in Sunnyvale, California. The following shall be the minimum requirements for the item listed above: The Smart Cycler System shall be able to distinguish multiple wavelengths (450-800 nM) of emmisions from fluorescent compounds such as that of al least 4 colors may be optically detected and separately measured; The system shall be self-contained and capable of being transported to field assays conditions; The system shall be able to provide real-time display of detection of fluorescence during the PCR reaction; The PCR reactions for each detection cycle shall be completed within 45 minutes of initiation of the cycling; The Smart Cycler System shall have separately programmable chambers for detection and shall have at least 16 such independently controlled detectors; In the Case of Failure: the separately programmable chambers shall be replaceable without affecting the performance of the other chambers; and The Smart Cycler System shall accommodate both small(25 microliter) and larger(100 microliter) sample volumes. All offerers shall include completed copies of Far Clause: 52.212-3 Representations and Certifications)and Far Clause: 52.222-70 (Compliance with Veterans Employment Requirements). Fax quotations are acceptable to the attention of: John Wilkinson at Fax number: 301-504-8696 on or Before August 11, 2001. Quotations shall include all specifications and literature pertaining to this requirement which demonstrate the capabilities for meeting the requirement. The evaluation factors for this requirement are price and past performance. Anticipated award date is August 19, 2001.
Record
Loren Data Corp. 20010727/66SOL010.HTM (W-206 SN50S990)

66 - Instruments and Laboratory Equipment Index  |  Issue Index |
Created on July 25, 2001 by Loren Data Corp. -- info@ld.com