Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF MAY 23, 2001 PSA #2857
SOLICITATIONS

49 -- BEAD BLAST CHAMBER FILTER CHANGE/REFURBISHMENT

Notice Date
May 21, 2001
Contracting Office
Department of the Air Force, Air Mobility Command, 22 CONS, = 53147 Kansas St Suite 102, McConnell AFB, KS, 67221-3606
ZIP Code
67221-3606
Solicitation Number
F14614-01-T-0012
Response Due
May 25, 2001
Point of Contact
Aaron Rutland, Contract Specialist, Phone (316) 759-4512, Fax = (316) 759-4507, Email aaron.rutland@mcconnell.af.mil
Description
This is a combined synopsis/solicitation for commercial items = prepared in accordance with the format in Subpart 12.6, as supplemented = with additional information included in this notice. This announcement = constitutes the only solicitation; proposals are being requested and a = written solicitation will not be issued.=20 F14614-01-T-0012 is being issued as a Request for Quotation, which = incorporates provisions and clauses for commercial items in effect = through Federal Acquisition Circular 97-24. This acquisition is = completely set-aside for small businesses in accordance with FAR = 19.502(a). The associated NAICS code for this acquisition is 333999 = with a size standard of 500 employees.=20 McConnell AFB, KS plans to procure services for the refurbishment of a = Pauli and Griffen 15_x12_x20_ blast room. . The contractor shall = provide all personnel, equipment, tools, materials, repair parts, = transportation, supervision and other items and services necessary to = provide the following: (1) the installation of a HEPA filter assembly. = Unit shall be rated at 12,000 CFM, and include six pre-filters and six = HEPA filters rated at 2,000 CFM. Unit shall also include magnehelic = gauges to measure pressure drop across filters (Pauli Part Number = 470-001-21 or equal), (2) installation of sweep-in pneumatic recovery = floor unit for plastic abrasives. Installation shall include concrete = work on existing slab floor (Pauli Part Number 250-031-03 or equal), = (3) removal and replacement of 24 ea. filter cartridges for pram unit = (dust collector). Contractor shall be responsible for the proper = disposition of all used filters and filter material (Pauli Filter Part = Number 240-050-01 or equal). A site visit will be held on 11 May 2001 = at 1:00 PM at McConnell AFB, KS. Interested parties are encouraged to = attend. The site visit will allow interested parties to make a visual = assessment of the equipment to be serviced. Contact the contract = administrator in order to arrange base access. The following provisions in their latest editions apply to this = solicitation: FAR 52.212-1, Instructions to Offerors _ Commercial FAR 52.212-2, Evaluation _ Commercial items.=20 FAR 52.212-3, Offerors Representations and certifications _ Commercial = Items (offerors shall include a completed copy as part of their quote) FAR 52.212-4, Contract Terms and Conditions _ Commercial Items FAR 52.212-5, Contract Terms and Conditions Required to Implement = Statutes or Executive Orders Additional FAR clauses cited within the above clauses, which are = applicable, will be incorporated into the solicitation and the = resulting contract. Award will be made to the low, responsive, = responsible offeror who submits an acceptable quote in full compliance = with the requirements of the RFQ. Offers shall be structured and submitted in accordance with the = following schedule: 0001 HEPA Filter 01 ea, 0002 Recovery Assembly 01 ea, 0003 Filter Cartridges for Dust Collector 01 ea, 0004 Installation 01 ea. =20 Interested parties should contact SSgt Aaron Rutland at McConnell AFB, = KS in order to RSVP for the site visit. Offerors shall respond to this = solicitation by 4:30 PM, on 14 May 2001. Offers can be faxed to = (316)759-4507, or e-mailed to aaron.rutland@mcconnell.af.mil . Following are questions concerning the refurbishment of the blast room = that were addressed at the site visit & need clarification: Q. Sweep In Floor Section ? What is the length and width required for = the sweep in section? A. 15ft long X 12 inch wide and 12 inch deep Q. What is the load capacity required for the sweep in section? A. 2000 lbs per square inch Q. What is the thickness of the concrete? A. 6? Q. Is there any below grade obstructions in the area to be dug out for = the pit? A. Yes there is an electrical conduit pipe approximately 18? down. Q. Is the government or the contractor responsible for disposing of = the dirt and broken concrete from the pit area?=20 A. Contractor Q. Is there any hazardous material contamination in the area?=20 A. Not that we are aware of Q. It is assumed that the government is responsible for insuring that = the existing exhauster and booster fan are operational and in good = condition, capable of recovering the spent media from the sweep in = section. A. Yes, the equipment has been tested and is operational. Q. What is the distance from the top of the dust collector to the = ceiling? A. 55
Web Link
Visit this URL for the latest information about this (http://www.eps.gov/spg/USAF/AMC/22CONS/F14614-01-T-0012/listing.htm= l)
Record
Loren Data Corp. 20010523/49SOL003.HTM (D-141 SN50M7A0)

49 - Maintenance Repair Shop Equipment Index  |  Issue Index |
Created on May 21, 2001 by Loren Data Corp. -- info@ld.com