COMMERCE BUSINESS DAILY ISSUE OF MARCH 6, 2001 PSA #2801
SOLICITATIONS
66 -- ANGLE OF ATTACK FOR WIND TUNNEL MODELS
- Notice Date
- March 2, 2001
- Contracting Office
- NASA/Glenn Research Center, 21000 Brookpark Road, Cleveland, OH 44135
- ZIP Code
- 44135
- Solicitation Number
- 3-170583
- Response Due
- March 13, 2001
- Point of Contact
- Sonia M Schriver, Contract Specialist, Phone (216) 433-2811, Fax (216) 433-5489, Email sonia.m.schriver@grc.nasa.gov
- E-Mail Address
- Sonia M Schriver (sonia.m.schriver@grc.nasa.gov)
- Description
- This is a modification to the synopsis entitled Angle of Attack for Wind Tunnel Models 3-170583 which was posted on February 27, 2001. You are notified that the following changes are made: This corrects typographical errors concerning the technical measurements found in the original solicitation. Replace specification A. 7-9, A. 12-14, and B.1 with the following specifications: A) AOA Sensor Package 7) A 10% variation in either or both supply voltages shall shift the bias less than 30 microG and shall shift the scale factor less than .01%. 8) Unfiltered output noise shall not exceed 8 microG RMS below 10 Hz and 80 microG RMS between 10 Hz. and 500 Hz. 9) Nonlinearity and hysteresis shall not exceed 35 microG over a range of 1 1 G. 12) Stability: at a constant temperature of 71 C, no reading with package level shall differ from any other reading with package level by more than 80 microG for four hours (after a 30 minute warm-up). Sensitivity shall not shift more than .03% during the same four hour period. 13) Rectification: 4G RMS random vibration (constant energy per hertz of bandwidth) in any axis shall cause an output shift of 100 microG or less in the 50-5000 Hz band. Sinusoidal acceleration of 3 G in any axis shall cause: a. an output shift of 90 microG or less in the 50-1000 Hz band. b. an output shift of 500 microG or less in the 1000-2000 Hz band. c. an output shift of 1000 microG or less in the 2000-5000 Hz band. 14) Permanent bias shift caused by any environment in these specifications shall be 180 microG or less. B) Signal Conditioner 1) Shall have an internal DC power supply capable of providing both +15 Vdc and -15 Vdc relative to power and AOA signal common and both supplies shall provide sufficient current to power an AOA requiring a maximum current of 20 mA from each supply. The accuracy of both supply voltages shall be 11%. The due date for receipt of quotes is not extended. Documents related to this procurement are available over the Internet and are in Microsoft Office 97 format and will reside on a World Wide Web (WWW) server, which may be accessed using a WWW browser application. The Internet site, or URL, for the NASA/GRC Business Opportunities home page is http://nais.msfc.nasa.gov/cgi-bin/EPS/bizops.cgi?gr=CL&pin=22 Offerors are responsible for monitoring this site for the release of the solicitation and any amendments. Potential offerors are responsible for downloading their own copy of the solicitation and amendments (if any).
- Web Link
- Click here for the latest information about this notice (http://nais.msfc.nasa.gov/cgi-bin/EPS/bizops.cgi?gr=D&pin=22#3-170583)
- Record
- Loren Data Corp. 20010306/66SOL011.HTM (D-061 SN50F0L3)
| 66 - Instruments and Laboratory Equipment Index
|
Issue Index |
Created on March 2, 2001 by Loren Data Corp. --
info@ld.com
|
|
|
|