Loren Data Corp.

'

  
COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 6, 2000 PSA #2701
SOLICITATIONS

38 -- FIXED INSTALLATION FLOWMETER, DIGITAL

Notice Date
October 4, 2000
Contracting Office
Fleet & Industrial Supply Center, Norfolk Naval Shipyard Annex, Purchase Division, Bldg. 1500, Portsmouth, VA 23709-5000
ZIP Code
23709-5000
Solicitation Number
N00181-00-Q-0855
Point of Contact
Lolita Waters (757) 396-8348
E-Mail Address
waterslf@nnsy.navy.mil (waterslf@nnsy.navy.mil)
Description
The solicitation number is N00181-Q-0855, SIC 3824 with a standard of 500 employees applies. This requirement is for a fixed price contract for the following items: 0001 DF868 fixed installation flow-meter , digital display with graphic capability, data-logging capability, two 4-20 MA (0-20 ma) isolated outputs and RS232 output. single channel. 100 to 120 VAC. Nema-4X weatherproof epoxy coated aluminum enclosure with window and external keyboard; suitable for class 1, div 2, A,B,C,D hazardous areas. Two built-in assignable isolated outputs 4-20MA outputs (0-20MA) S @ CSA/Tropicalization, Panameterics P/N: DF86811110000-S or equal; (6) AY Item 0002: (6) PR, Pair of clamp-on transducers. Panameterics P/N C-PT-10-M-U-EX-0 or equal. General purpose, high efficiency, plastic/metal shear wave, for 2 in (50MM) NB and larger pipe, (10 Inch IPS 70/30 CU-NI pipe). Certification as follows: Europe: EEXDM IICT6. Canada: CSA Class 1, Div 1, Group C & D. USA: Non-hazardous areas, use CPB for hazardous areas. 1 MHZ, standard materials, middle temperature CPT: 20 to 145 Deg C (-4 to 290 Deg F), CPB: -40 to 150 Deg C (-40 to 300 Deg F), CTS: not available. Submersible UHF connector with o-ring (requires submersible cable). Flameproof junction box, EEXD IICT 6 rating. Item 0003: (6) EA. Panameterics P/N CF-BL-P-SR-XX-O or equal, General clamping fixture for permanent installations: 2 coated aluminum brackets with double fastener mount for pipes greater than 2 inch (50MM). For use with plastic transducers CPT & CPB. SS strap for CFYK, CFBL and CF-BW fixtures. Pipe size: N/A, Flowmeter to be mounted on bulkhead stanchion. Item 0004: (6) PR, Panameterics P/N C(*)N2SUB or equal, pair of coaxial cables, (8) ft long. Submersible connector fitted to transducer end of coaxial cable & tinned leads for the electronic console end. Data Requirements: (1) se: Grade "A" shock and vibration tests IAW MIL-S-901D & MIL-STD 167B-1, (1) se: (PTD) Provisioning Technical Documentation, IAW MIL-HDBK-502, and (5) se: Commercial Manual. Delivery will be Norfolk Naval Shipyard. Requests for the quotation must be in by e-mail or in writing and submitted via regular or expedited mail service to Purchase Division, Code 531.4E, Attn: L. Waters, Fleet and Industrial Supply Center, Norfolk Naval Shipyard Annex, Portsmouth, VA 23709-5000. Fax and/or phone requests are not allowed and will not be considered.
Record
Loren Data Corp. 20001006/38SOL001.HTM (W-278 SN5034Y2)

38 - Construction, Mining, Excavating and Highway Maintenance Equip. Index  |  Issue Index |
Created on October 4, 2000 by Loren Data Corp. -- info@ld.com