COMMERCE BUSINESS DAILY ISSUE OF AUGUST 30,2000 PSA#2675 Department of Veterans Affairs Medical Center, Chief, Acquisition and
Materiel Management (90C), One Veterans Drive, Minneapolis, MN 55417 65 -- LEASE DIGITAL CARDIOVASSCULAR MOBILE C-ARM PLATFORM SOL RFQ
618-36-01 DUE 092000 POC Janice M. Byrd 612-725-2188 This is a combined
synopsis/solicitation. Request for Quotation RFQ 618-36-01 entitled
"Lease of Digital Cardiovascular Mobile C-Arm Vascular Platform and
Imaging Table" brand name or equal is hereby issued for commercial
items and is prepared in accordance with the format in Federal
Acquisition Regulation (FAR) Part 12, Acquisition of Commercial Items,
Subpart 12.6, Streamlined Procedures for Evaluation and Solicitation
for Commercial Items, Part 13, Simplified Acquisition Procedures, and
as supplemented with additional information included in this notice.
This procurement is being conducted under Federal Acquisition
Regulation (FAR) Subpart 13.5 test program; simplified acquisition
procedures apply and the VA will conduct the procurement according to
a combination of Parts 12 and 13. This announcement incorporates
provisions and clauses in effect through FAR FAC 97-19 and VAAR 97-8.
NAICS Code 334516 applies for this procurement (formerly SIC code 3827)
and the small business size standard is 500 employees. A separate
written solicitation document will not be issued. Contractor's
proposals are hereby being requested and response to requirements
listed below shall be sumitted on contractor's letterhead and must
address all requirements listed below and should contain the name,
title and signature of person authorized to submit proposals/bids on
behalf of the contractor. Descriptive literature for each item offered
must also be included in proposal/bid package. The VA Medical Center
(VAMC), Minneapolis, MN, has a requirement for an operating lease for
one year with the option to buy the equipment or renew the lease for
another year, or cancel the lease at end of base or option period for
brand name or equal OEC Medical Systems, Inc., 384 Wright Brother
Drive, Salt Lake City, Utah, 84116 equipment described as follows: Item
One (1ea) Series 9800 Digital Mobile C-arm Vascular Platform configured
with the following (a) X-ray Generator -- 15kW, 60kHz high frequency;
Full power from a standard wall outlet (120V, 15amp); Patented battery
buffered design; 40 to 120kVp range; 0.2 10 mA range: Fluoroscopy;
1-20 mA range: High Level Fluoroscopy; Pulsed Fluoroscopy mode, 1,2,4,8
& 15 puluses per second; Digital Spot mode up to 75 mA; High Level
Pulsed Fluoro mode up to 40 mA @ 1,2,4, or 8 pps; Digital Cine Pulse
mode: 40-120 kVp, up to 150 mA, 10 ms pulse widths, 15 pps. (b) X-ray
Tube & Collimation Rotating anode x-ray tube with 0.3mm and 0.6mm focal
spots; 300,000 HU anode heat capacity; 1,600,000 HU housing heat
capacity; Preview TM on-screen collimator position indication; Iris
collimator and semi-transparent dual leaf collimator. (c) Video Imaging
System 9"/6"/4.5" (23/15/11cm) image intensifier; High resolution, 1k
x 1k CCD camera with full-frame capture; 1,000 line, high resolution
dual 16" square TV monitors (19" diagonal equivalent), anti-glare,
progressive full-frame scan; Ambient room light sensor. (d) Digital
Image Processing and Workstation 1k x 1k x 16 bit digital image
processing; AutoTrak TM automatic brightness stabilization; Touchscreen
user interface & multi-function footswitch control; Noise filter with
on-screen indicator; Real-time motion artifact and noise reduction
system; Real-time variable edge enhancement; Zoom & Roam; Negate mode;
Automatic and manual contrast and brightness control; 400 image
storage with last image hold; Save and auto save; swap & auto swap
features; Patient information/annotation and image directory; Image
annotation: markers, comments, cropping; X-ray dose summary, may be
printed with hard copy documentation; Removable PC diskette image
transfer and archive: OEC or BMP formats. (e) Vascular Package
Real-time Subtraction; Roadmapping; Peak Opacification; Re-registration
(pixel shifting) Variable Landmarking; Mask save/recall; Digital Cine
Pulse mode: 15 pps at 10ms pulse widths, up to 150 mA; 15 F/S digital
disk: 1,2,4,8 & 15, fps record rates with 4,500 image storage for up to
5 min. record capacity at 15 fps; Frame by frame review; Automatic
digitalcine run playback. (f) C-arm Mechanics Counterbalanced, manual
adjustment of orbital rotation, cranial-caudial rotation, wig-wag and
horizontal motion; Patented flip-flop C-arm reversal; 31" free space,
26" depth in arc, 115 degree orbital rotation; Dual, illuminated C-arm
operator control panels. (g) Options Intergrated DICOM 3.0 Interface:
Storage Class, Print Class and Query Worklist; Integrated laser
quality film & paper printer (dry process): 8x10" film or paper with
1,2, and 4 on 1 formats; 12" Image Intensifier; External High
Resolution Monitor, FIMI, 21"; Laser Aimer, 12". (h) Included Unpacking
and Installation. Three days of in-service by ARRT certified X-ray
technologists. ECE points for the American Society of Radiologic
Technologists which can be applied towards the technologists' license.
Training of Radiology Staff, Operating Room Staff, and Physicians.
Warranty twelve months; Y2K Compliance Warranty. Item Two: (1ea) GE OEC
APIX Cardiovalcular Mobile Imaging Table. (a) Electrical power
requirements: 120V @ 60 Hz 10 Amps, 240V @ 50 Hz 5 Amps; (b) Patient
Load Capacity 400lbs; (c) Demensions: Table top length (retracted) 90";
Table top width 30"; dimension of Imageable area: 18" x 84"; (d)
Movements: Lateral travel +/-6"; Longitudinal travel 48"; Trendelenburg
travel +/- 20 degrees; Lowest table height 30"; Hightest table height
42"; Lateral Roll/Tilt +/- 20 degrees. (e) General: Table top
composition carbon fiber; Table top radiolucency .55mm Al Equivalent;
Table pad radiolucency .50mm Al Equivalent (1/2 pad std.); Acessories
included: " low attenuation table pad, single C.F. arm board with pad,
C.F. tabletop accessory plate, restraint strap, wristlets, control
panel covers (1 case of 25), control panel, and hand control. Delivery
terms shall be FOB Destination (unless vendor states otherwise) to the
VA Medical Center, Warehouse (90D), One Veterans Drive, Minneapolis, MN
55417. This will be a firm fixed price lease agreement. Payment may be
made by Government Purchase Card (VISA). Evaluations may be conducted
to determine that the products offered will meet Government's
requirements. Offerors must indicate in their proposals the price at
which they would be willing to sell the equipment should the Government
elect to purchase at a later date, prior to expiration of the lease
agreement; offerors must also specify the latest date such an option
may be exercised by the Government and how much of the lease cost
already paid by the Government may be applied against the purchase
price quoted. Evaluation factors of technical capability of the items
offered and past performance history, and delivery time frame will be
considered along with the maximum period of use at the lowest total
price to determine "best value" to the Government. Evaluation may be
made with or without discussions with the offeror(s). All responsible
sources that can meet the requirements and provide items as listed
above may respond to this solicitation by submitting cost and technical
proposals on their company letterhead or bid form. The following
provisions and clauses shall apply to this solicitation: 52.252-2
Clauses Incorporated by Reference. This contract incorporates one or
more clauses by reference, with the same force and effect as if they
were given in full text. Upon request, the Contracting Officer will
make their full text available. Also, the full text of a clause may be
accessed electronically at this/these address (es):
http://www.arnet.gov/far (FAR) and http://www.va.govoa&mm/vaar/ (VAAR);
52.212-1 Instructions to Offerors Commercial Items; 52.212-2 Evaluation
Commercial Items; 52.212-3 Offeror Representations and
Certification-Commercial Items (NOTE Offerors must include a completed
copy of "Offeror Representations and Certification" along with his/her
offer); 52.212-4 Contract Terms and Conditions Commercial Items;
52.212-5 Contract Terms and Conditions Required to Implement Statutes
on Executive Orders Commercial Items; FAR 52.211-6 Brand Name or Equal;
FAR 52.214-21 Descriptive Literature; FAR 52.216-18 Ordering;FAR
52.216-19 Order Limitations; FAR 52.216-21 Requirements; FAR 52.232-18
Availability of Funds;VAAR 852.211-75 Technical Industry Standards;
VAAR 852.211.77 Brand Name or Equal; VAAR 852.270-4 Commercial
Advertising; VAAR 852.219-70 Veteran-owned business; 852.219-70 Protest
Content; 852.236-76 Correspondence; 852.237-70 Contractor
Responsibilities; 852.270-1 Representatives of Contracting Officers;
and 852.233-71 Alternate Protest Procedure. Proposals shall include all
information required in 52.212-1, Schedule of Prices Offered, a copy of
published price list for the services proposed, and a completed copy of
provision 52-212-3. Submit all price, descriptive literature and
technical proposals to Janice M. Byrd, Contracting Officer (90C), VA
Medical Center, Room 4G-107, One Veterans Drive, Minneapolis, MN 55417.
For further information, contact Janice M. Byrd at (612) 725-2188.
Offeror's proposals are due by Noon on September 20, 2000. Faxed
proposals will be accepted. Posted 08/28/00 (W-SN490839). (0241) Loren Data Corp. http://www.ld.com (SYN# 0255 20000830\65-0003.SOL)
| 65 - Medical, Dental and Veterinary Equipment and Supplies Index
|
Issue Index |
Created on August 28, 2000 by Loren Data Corp. --