COMMERCE BUSINESS DAILY ISSUE OF MAY 18,2000 PSA#2603USAED, Walla Walla, ATTN: CENPW-CT, 201 North Third Avenue, Walla
Walla, WA 99362-1876 59 -- GENERATOR UNITS 1 THRU 6 EXCITER REPLACEMENT, ICE HARBOR DAM,
SNAKE RIVER, WALLA WALLA COUNTY, WASHINGTON SOL DACW68-00-R-0031 DUE
070600 POC To order solicitation package, interested firms may: 1) fax
requests, complete with company information, shipping address, point
of contact, DUNS and CAGE code nos., phone and fax numbers, as well as
business size, to Kari Montgomery, fax 509-527-7802; 2) e-mail request
with same company information to the address below; or 3) register via
the Walla Walla District's Web Page at the URL listed below. POC for
administration, Kari Montgomery, telephone 509-527-7211. Technical POC,
John Boschker, telephone 509-527-7541. WEB: Click here to register for
solicitation package.,
http://www.nww.usace.army.mil/ebs/asp/advertisedsolicitations.asp.
E-MAIL: Solicitation No. DACW68-00-R-0031,
Karoleen.A.Montgomery@usace.army.mil. The U.S. Army Corps of Engineers,
Walla Walla District, has a competitive requirement for all labor,
material, equipment and plant to design, manufacture and install six
complete digital excitation systems for the Ice Harbor Dam powerhouse
main units 1 through 6, located on Snake River, Walla Walla County,
Washington. (NOTE: This request for proposal (RFP) was previously
advertised as an information for bid' solicitation DACW68-00-B-0026.
Technical description is not changed. Vendors proposals will be
evaluated in accordance with criteria listed in the solicitation. A
tentative listing of evaluation criteria is shown below.) All units
were manufactured by General Electric, rotate at 90 rpm and have a
power factor of 95 percent. Units 1-3 are rated at 94,737 KVA and units
4-6 are rated at 116,800 KVA. The work includes, but is not limited to,
the following items: 1) remove the existing six excitation systems'
non-rotating parts; 2) remove existing excitation power, signal, and
control cabling and provide new power, signal, and control cabling for
the new excitation systems; 3) provide one molded case circuit breaker
and the required cabling for exciter field flashing; 4) provide
fully-configured graphic user interface (GUI) software for an
operator-machine interface (OMI) station in the powerhouse control
room. The OMI shall provide for complete data acquisition and control
capabilities of the six new exciters. Data transfer between the OMI and
the exciters shall be full duplex and shall utilize a single digital
highway connecting the exciters and the OMI station; and 5) provide
training for Government personnel on the operation and maintenance of
the new exciters. Contract completion shall be approximately 500
calendar days after award. Transportation costs f.o.b. destination.
Offerors proposals will be evaluated on criteria indicated in the
solicitation. A tentative listing of the main factors that will be
evaluated, are listed below in descending order of importance (NOTE: As
stated, this is a tentative listing. Factors and their relative order
of importance will be specified in the solicitation): 1) quality of
design, 2) testing methodology and procedure; 3) past performance, 4)
maintainability, 5) quality and timeliness of schedule, 6) price, 7)
efficiency, and 8) software provided. PROCUREMENT UNRESTRICTED. Size
standard for identification of small business concerns under Standard
Industrial Classification Code 3621, is that the average employment,
based on the number of persons employed on a full-time-, part-time,
temporary, or other basis during each of the pay periods of the
preceding 12 months, shall not exceed 1,000 employees. If a large
business is selected for this procurement, it must comply with FAR
52.219-9 regarding the requirement for a subcontracting plan on the
portion of the work it intends to subcontract. The subcontracting GOALS
are: a minimum of 61.2 percent of the Contractor's intended subcontract
amount be placed with small businesses (SB), including 9.1 percent with
small disadvantaged businesses (SDB). A minimum of 5 percent of the
intended subcontract amount shall be placed with woman-owned small
businesses (WOSB). It has NOT been determined whether bonding will be
required. This is not a request for proposals, but notice that our
intention is to issue a solicitation for this requirement. Vendors who
have requested solicitations under the previous number,
DACW68-00-B-0026, will remain on the bidders mailing list and need not
re-register for this RFP. All responsible sources may submit an offer,
which will be considered by this agency. (NOTE: Issue and response
dates are tentative and will be established when solicitation is
issued.) Posted 05/16/00 (W-SN455579). (0137) Loren Data Corp. http://www.ld.com (SYN# 0284 20000518\59-0009.SOL)