COMMERCE BUSINESS DAILY ISSUE OF MAY 11,2000 PSA#2598Department of the Air Force, Air Force Space Command, 30CONS, Bldg
7015, STE 2D, 806 13th Street, Vandenberg AFB, CA, 93437-5226 H -- OPERATIONAL EVALUATION AND WRITTEN REPORT OF VAFB AIRFIELD
APPROACH LIGHTING SYSTEM SOL 00T0684 DUE 052400 POC Rich Otton,
Contract Specialist, Phone 805.606.2169, Fax 805.606.4863, Email
richard.otton@vandenberg.af.mil -- Debbie Spangler, Contracting
Officer, Phone Comm: 805.605.8718, Fax 805-922-1703, Email WEB: Visit
this URL for the latest information about this,
http://www.eps.gov/cgi-bin/WebObjects/EPS?ACode=P&ProjID=00T0684&LocID
=528. E-MAIL: Rich Otton, richard.otton@vandenberg.af.mil. The 30th
Space Wing, Vandenberg AFB, is soliciting offers to provide an
operational evaluation and written report of the VAFB Airfield Approach
Lighting System. This is a combined synopsis/solicitation for
commercial items prepared in accordance with the format in subpart
12.6, as supplemented with additional information included in this
notice. This announcement constitutes the only solicitation. Quotes are
being requested and a written solicitation will not be issued. The
solicitation number is F04684-00-T0684 and will be issued as a request
for quotation. The solicitation document and incorporated provisions
and clauses are those in effect through Federal Acquisition Circular
97-16. The SIC code is 9999 and the size standard is $5,000,000. This
acquisition is a 100% small business set-aside. The Contractor is to
provide all labor, tools, parts, materials, transportation, facilities
and supervision necessary to accomplish the following task: Contractor
will provide an operational evaluation and written report of the VAFB
Airfield Lighting System, specifically the sequence flashing system.
Work shall be limited to the sequence flashing system only. Description
of the system is as follows: The sequence flashing system is a Godrey
Lighting Controller, manufactured by the Honeywell Corporation. The
system consists of two(2) master control cabinets, forty-two(42)
individual control cabinets with flash-head assemblies and associated
control cables. Each master control system controls one end of the
runway. A computer, located in the airfield vault, controls the
sequence flashing system through two interface control nodes that
connect the computer to the two(2) master control cabinets. The runway
is approximately 15,000' long. The evaluation shall consist of the
following: 1) Each master control cabinet shall be tested for proper
operation. Verify Inputs and Outputs of each master control cabinet. 2)
Each Individual Control Cabinet with flash head assembly shall be
tested for proper operation. Verify Inputs andOutputs of each
individual control cabinet. 3) The contractor shall test and verify all
control cables from both control nodes located in the airfield vault to
each master control cabinet. Master Control Cabinets are located in two
below ground vaults. 4) The contractor shall test and verify all
control cables from master control cabinets to each individual control
cabinet and flash-head assembly. 5) The contractor shall provide a
written report identifying all discrepancies found during evaluation.
Any cable replacement recommendations, printed circuit board
replacements/repairs, or any other items identified for repair or
replacement shall be identified by means of a diagram. In the interest
of money, diagrams can be hand-drawn, however, they must be detailed
enough to show precise locations of the deficient items. 6) The
contractor shall provide a rough estimate of materials required to
completely repair the sequence flashing system. Repairs must thoroughly
re-establish this system in accordance with AF Regulation 88-14, Visual
Air Navigation Facilities, US Department of Transportation Federal
Aviation Administration Standards, Specifications, and Drawings
FAA-E2628B Advisory Circular dated 8/26/82, AC No. 150/5340-26 and any
other FAA rules and regulations. 7) The contractor shall provide, as
a separate line item, all labor costs required to make the repairs as
indicated in the estimate of materials. 8) The contractor must be an
authorized and certified repair company approved to evaluate and make
repairs to the Sequence Flashing System. Further, the contractor shall
be certified to evaluate and repair the Godrey Sequence Flashing
System manufactured by the Honeywell Corporation. Appropriate and
applicable FAA certifications shall be required. Please include product
literature for each item needed to be repaired. In your quote, please
indicate the length of time to evaluate the runway. The provisions at
FAR 52.212-1, "Instructions to Offerors-Commercial" apply to this
acquisition. The provisions at FAR 52.212-2, "Evaluation-Commercial
Items" apply to this acquisition. This item being procured and will be
awarded using simplified acquisition procedures in accordance with FAR
13.0. Offerors must submit a completed copy of the provision at FAR
52.212-3, "Offeror Representations and Certifications-Commercial
Items." The clause at FAR 52.212-4, "Contract Terms and
Conditions-Commercial Items" applies to this acquisition. DFARS clauses
are incorporated in this solicitation with the same force and effect as
if they were given in full text. The DFARS clause 252.212-7000,
"Offeror Representations and Certifications -- Commercial Items"
applies to this acquisition. The clause at FAR 52.212-5, "Contract
Terms and Conditions Required to Implement Statutes or Executive
Orders-Commercial Items" and DFARS 252.212-7001, "Contract Terms and
Conditions Required to Implement Statutes or Executive Orders
Applicable to Defense Acquisition of Commercial Items" applies to this
acquisition along with the following additional clauses: 52.203-6,
"Restrictions on Subcontractor Sales to the Government" 52.222-21,
"Prohibition of Segregated Facilities" 52.222-26, "Equal Opportunity"
52.222-35, "Affirmative Action for Disabled Veterans and Veterans of
the Vietnam Era" 52.222-36, "Affirmative Action for Workers with
Disabilities" 52.222-37, "Employment Reports on Disabled Veterans and
Veterans of the Vietnam Era" 52.225-3, "Buy American Act -- Supplies"
52.225-9, "Buy American Act -- Trade Agreements -- Balance of Payments
Program" 52.225-18, "European Union Sanction for End Products"
52.225-21, "Buy American Act -- North American Free Trade Agreement
Implementation Act -- Balance of Payments Program Certificate"
52.232-33, "[Payment by] Electronic Funds Transfer [ -- Central
Contractor Registration]" 252.225-7001, Buy American Act and Balance of
Payment Program, 252.225.7036, Buy American Act -- North American Free
Trade Agreement Implementation Act -- Balance of Payment Program.
Offerors must be CCR certified in order to receive award of this
purchase order. Offers must be submitted in written responses mailed or
faxed and received no later than 4:00 p.m. on 24 May 00; to the
attention of Lt. Rich Otton, 30 CONS/LGCC, Bldg 7015, Section 2,
Vandenberg AFB, CA. 93437-5226. Oral responses are not acceptable. Any
questions or comments may be addressed to me at (805) 606-2169 or
faxed to (805) 606-4071. Please fax all questions no later than 4:00
p.m. on 23 May 00. Quote validity is for 60 days from the date of the
quote. Please include the solicitation number on all correspondence
dealing with this acquisition. Posted 05/09/00 (D-SN452987). (0130) Loren Data Corp. http://www.ld.com (SYN# 0035 20000511\H-0001.SOL)
H - Quality Control, Testing and Inspection Services Index Page
|
|