|
COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 15,1999 PSA#2432US Army Corps of Engineers, Engineering and Support Center Huntsville,
4820 University Square, Huntsville, AL 35816-1822 47 -- PIPE, TUBING, HOSE, FITTINGS AND FILTERS SOL DACA87-99-Q-0162
DUE 091799 POC Evelyn Kelley, Contract Specialist, (256)895-1317
E-MAIL: Lydia.B.Tadesse@HND01.usace.army.mil,
EvelynH.Kelly@HND01.usace.army.mil. This is a combined
Synopsis/Solicitation for commercial Items prepared in accordance with
the format in Subpart 12.6, as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation; proposals are being requested and A WRITTEN
SOLICITATION WILL NOT BE ISSUED. The U.S. Army Engineering and Support
Center, Huntsville has a requirement for Filters for filtration units
for an Engineering Vapor Containment Structure for the following
project: 4 Memphis Depot Units: Memphis Depot Specification for 48
Charcoal Filters (24" X 24" X 18"). Carbon modules shall be filled with
Type CG11 (Cooperite), 12x30 mesh carbon for the removal of military
agents and in accordance with ASCZM-TEDA. Adsorber cell frame shall be
24" x 24"x18". The absorber cell shall be in accordance with Institute
of Environmental Sciences, IES-RP-CC-008-84, as modified in Annex A,
dated 3 March 1997. Each charcoal filter will provide a resonance time
of 0.25. In IES-RP-CC-008-84, as modified in Annex A, dated 3 March
1997, section 7.3 DMMP Breakthrough Life, change PLUS the eight cells
to undergo this destructive test to PLUS the 5 cells to undergo this
destructructive test Memphis Depot 32 Each HEPA Filters Specifications:
Each filter shall be individually tested and certified by the
manufacturer's Q107 penetrometer (or equivalent) to have an efficiency
of not less than 99.97% when tested with 0.3 micron thermally
generated DOP smoke. Testing to leak-free scan requirements and
resistance to airflow are performed per Federal Std. 209-latest issue
at nominal rated capacity (CFM). Test results shall be recorded on each
filter. Clean filter static pressure drop shall be no greater than 1.3"
w.g. when operated at rated capacity (500 fpm). Filter media shall be
composed of high alpha, modified matrix, 100% microglass media,
waterproofed to withstand a 100% RH factor and shall not contain
asbestos. Filters shall be factory constructed using shallow fluted
aluminum separators. Adhesive sealers shall be fire retardant flexible
urethane. The media pack shall be permanently sealed with a frame of
16 ga., Type 304 stainless steel. Overall filter dimensions shall be
correct to within +0" to 1/8" and squareness to be within 1/8". Each
filter shall be supplied with a permanently affixed dovetailed SCE43
closed cell neoprene gasket on the upstream filter face. Filters shall
be tested and certified to comply with the performance criteria under
Federal Std. 209 latest issue. For Type A and C filters.
Specifications for Memphis Depot, 16 Each Pre-Filters: The pre-filter
shall have an average efficiency of 80 to 85%. Flow capacity of 500 cfm
shall have resistance of 0.14" w.g. and at 1000 cfm have a resistance
of 0.34" w.g. The perimeter should be constructed of high strength,
corrosion resistant galvanized steel, to which the filter pack is
sealed on all sides. Delivery is to Transportation Office Bldg. E5185
EA, APG,MD 21010-5424 (ph. 410-436-2777) no later than February 29,
2000. The solicitation number to refer to in response to this notice is
DACA87-99-Q-0162. This requirement is being issued as a Request for
Quotation using Simplified Acquisition Procedures under the Test
Program at Subpart 13.6. This requirement is being procured on an
unrestricted basis; no small business set aside is being considered.
This requirement contains one CLIN, 0001, with firm quantities, for the
purpose of issuing a firm fixed price purchase order. FAR provision
52.212-1, Instruction to Offerors, applies to this solicitation with
the following addenda: (a) Delete; (b) Delete the text as written and
insert; Electronic submission of offers is permitted. ALL OFFERS MUST
BE RECEIVED BY THE 17TH DAY OF SEPTEMBER 1999 TO BE CONSIDERED TIMELY.
The Standard Industrial Classification Code for this solicitation is
3585 ($750.M). Minimally, offers must include the solicitation number,
the name, address, telephone number, facsimile number, e-mail address,
if available, a point of contact, complete with official title and
voice telephone number,pricing directly correlating to the CLIN
contained herein, any prompt payment discount terms offered, a
statement indicating whether payments can be made by electronic funds
transfer and a complete copy of the representations and certifications
required at FAR 52.212-3. Further, offers must contain all commercial
terms, conditions and provisions under which the offeror conducts
business in the commercial marketplace. The Government intends to award
a contract to the responsible offeror whose offer conforming to the
solicitation will be the most advantageous to the Government, price and
price related factors considered. FAR Clause 52.212-5, Contract Terms
and Conditions Required to Implement Statutes of Executive Orders-
Commercial Items, applies to this acquisition, and specifically:
52.222-26, Equal Opportunity; 52.222-35, Affirmative Action for Special
Disabled and Vietnam Era Veterans (38 U.S.C. 4212); 52.222-36.
Affirmative Action for Handicapped Workers (U.S.C. 793); 52.222-37,
Employment Reports on Special Disable Veterans and Veterans of the
Vietnam Era (38 U.S.C.4212); Upon request a hard copy of the
specifications will be provided. Offers must be received by 3:00 p.m.
local time, 17 Sep 1999. Mail, fax or e-mail to the attention of Evelyn
Posted 09/13/99 (W-SN379661). (0256) Loren Data Corp. http://www.ld.com (SYN# 0248 19990915\47-0002.SOL)
47 - Pipe, Tubing, Hose and Fittings Index Page
|
|