COMMERCE BUSINESS DAILY ISSUE OF AUGUST 18,1999 PSA#2412Naval Research Laboratory (NRL-SSC), Attn: Code 3235, Building 1100,
Room 107, Stennis Space Center, MS 39529-5004 J -- REFURBISHMENT OF NRL HORIZONTAL ARRAY AND ARRAY RECOVERY SYSTEM
SOL N00173-99-Q-6002 DUE 091099 POC Contract Specialist, Richard D.
Sewell, Code 3235:RS; Contracting Officer, Patricia A. Lewis, Code 3235
(228)688-5784 WEB: click here,
http://heron.nrl.navy.mil/contracts/home.htm. E-MAIL: click here,
ssccontracts@nrlssc.navy.mil. 17. The Naval Research Laboratory
(NRL-SSC) intends to negotiate a contract on the basis of Other Than
Full and Open Competition IAW 10 USC 2304(c)(1) with C & M Technology,
Inc., Old Saybrook, CT, for refurbishment of both the NRL Horizontal
Array and the associated Array Recovery System. Tasks associated with
this effort shall include the following: For tasks associated with
Array refurbishment, the Contractor shall (1) provide and install 32
new CM100HP hydrophones, (2)intersperse an additional 32 CM100HP
hydrophones with the existing phones to provide 1.25 meter spacing
between hydrophones for increased spatial resolution; (3) provide and
install 4 new upper and lower tile/heading packages with pressure
sensors to allow vertical use; (4) replace array cable and restore all
conductors to original operating condition; (5) restore hair fairing
to original condition along the length of the array; (6) replace all
connectors with new connectors; and (7) pressure test and calibrate the
array upon completion. Tasks associated with refurbishment and revision
of the existing Array Recovery System shall include the following: The
Contractor shall (1) provide and install a new stand and reel to
accommodate fiber optic umbilical cable plus two acoustic arrays with
sufficient capacity to hold the umbilical plus 250m of 2.5""diameter
array cable with an additional 3" of clear flange; (2) provide for
level wind and remote control options for uniform stowage of the
umbilical cable; (c) provide a 40HP motor to ensure against overheating
during system recovery; and (4) provide for operation on 230/460 VAC,
3 phase, 60 Hz. power. No telephone requests will be accepted in
response to this notification. All responsible sources are invited to
identify their interest and capability to respond to this requirement.
Only written information received directly from requestors will be
considered. Posted 08/16/99 (W-SN368103). (0228) Loren Data Corp. http://www.ld.com (SYN# 0031 19990818\J-0004.SOL)