Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JANUARY 11,1999 PSA#2259

440th Airlift Wing/General Mitchell International Airport, 300 E. College Avenue, Milwaukee, WI 53207-6299

65 -- PIXY PHANTOM ANTHROPOMORPHIC TEACHING AID WITH OPTIONS SOL F47606-99-T0022 DUE 020199 POC Mark L LaCroix 414-482-5270 The 440th Airlift Wing/General Mitchell International Airport, 300 East College Avenue, Milwuakee, WI 53207-6299, seeks sources for the purchase of a Pixy Phantom Anthropomorpnic Teaching/Training Phantom Aid, OR EQUAL, as manufactured by Radiology Support Devices Inc., 1904 E. Dominquez Street, Long Beach Ca, 90810, to include the following options: 1. Shoulder ball and socket joint, 2. Elbows and knees that flex 90 degrees, 3. Hips that flex 130 degrees with 30 degree hyperextension, 4. A frog postion made possible by lateral flexation of the hips, 5. Right hand that is molded with fingers positioned for an AP view, 6. Left hand is in an oblique lateral position, 7. Radiographs that are optically equivalent in density and contrast to human patients and permits unlimeted exposures, 8. Mechanical nylon joints with full range of head motion, 9. Organs that accept contrast media, opaque model, 10. Lungs that are tisue-equivalent foam with mass density of inflated human lungs (0.30g/cc). Lungs need to be connected to the oro-nasal cavity by the stem bronchi and trachea; oro-nasal pharnyz filled with nearly air-equivalent foam, 11. Device must contain abdominal and pelvic organs; stomach, gall bladder, urinary bladder, kidneys, rectum and sigmoid-flexure which can accept air, water or contarst media and are able to be flushed after each use, 12. Matching skeletons and soft tissues must permit external and bony landmarks to coincide. The position of bones withn the soft tissues must be anatomically correct. Latex coverings are needed to retain tissue equivalent gels for soft tissue continuity at the articulations. Two-ply coverings are required to protrect against gel leakage, 13. Pixy Model numbers; a. RS-102 Opaque Pixy Phantom; b. RS-150 Arterial Tree; c. RS-102SP Custom Fractures and Pathologies. Depressed skull fracture at any desired location, hairline fracture on the scaphoid bone of the wrist (with no fragment separation), Fracture of the superior pubic ramus, rib fracture at the mid-axillary line, unseparated fracture of the patella, stress fracture of the 5th tarsal bone of the extendec foot; d. RS-102R standard PIXY refurbishment. All responsible soruces who can provide this requirement may contact the 440th Airlift Wing, 300 East College Avenue, GMIAP, Milwaukee, WI 53207-6299, Mark L LaCroix at 414-482-5270 to request a solicitation package not later than 1 Feb 99. If no responses are received, award will be made to Radiology Support Devices Inc. Posted 01/07/99 (W-SN285885). (0007)

Loren Data Corp. http://www.ld.com (SYN# 0276 19990111\65-0005.SOL)


65 - Medical, Dental and Veterinary Equipment and Supplies Index Page