|
COMMERCE BUSINESS DAILY ISSUE OF JANUARY 4,1999 PSA#2254National Institute of Standards & Technology, Acquisition & Assistance
Div.,100 Bureau Drive Stop 3572, Bldg. 301, Rm B117, Gaithersburg, MD
20899-3572 66 -- RADIOMETERS SOL 53SBNB967031 DUE 011399 POC : Paul Cataldo,
Contracting Officer, Tel (301) 975-6332, or Anne McFarlane, Contract
Specialist, Tel (301) 975-4648, FAX (301) 963-7732, e-mail
anne.mcfarlane@nist.gov WEB: NIST Contracts Hompage,
http://www.nist.gov/admin/od/contract.htm. E-MAIL: NIST Contracts
Office, Contract@nist.gov. The National Institute of Standards and
Technology (NIST) intends to negotiate with Reyer Corporation of New
Market, MD for Radiometers on a sole source basis as follows: 001)
Model S10/1 Modular Radiometer, UV; 002) Model S10/16 Modular
Radiometer for the Near IR; 003) Model S10/14 Modular Radiometer,
Temperature controlled Pyroelectric Detector; 004) Model CT-1000
Transmission Trap Detector Module utilizing six 1337-1010B photodiodes;
005) Model DTD-1000 Trap Detector Module utilizing two detector sizes,
S1337-1010B and S6337-01 photodiodes; 006) Model RTD-1000 Reflection
Trap Detector Module utilizing three S6337-01 photodiodes; 007) Model
TTD-1000 Transmission Trap Detector Module utilizing three detector
sizes, S1337-66B, S1337-1010B and S6337-01 photodiodes. Reyer
Corporation has previously made design modifications, drawings,
prototype, and additional modular radiometers for a NIST designed
modular radiometer system. The new modular radiometers to be acquired
are to be constructed according to special NIST requirements. All units
are to be mounted in a uniform way. The special components are
specified by NIST, and must be interchangeable with each other. The
radiometers are modular and their sub units are to be interchangeable
with each other as well. The trap detectors are also modular and custom
designed. They are the only devices that can satisfy the NIST requested
high accuracy (0.03% uncertainty) of radiant power and irradiance
measurements between 406 nm and 920 nm. Similar quality trap devices
are not available in the market. All radiometers have to be compatible
to the existing NIST detector response calibration facilities. Reyer
Corporation is the only company who is trained and prepared by NIST to
design and fabricate different versions of the high accuracy modular
radiometers. They participated in the design of the power and
irradiance measuring trap detectors. The required delivery is 30 days
after receipt of order, FOB Destination, Gaithersburg, MD. The
statutory authority is 41USC 254 (c)(1), only one responsible source
that can meet the requirements of the Government. The proposed contract
action is for supplies or services for which the Government intends to
solicit and negotiate with only one source under the authority of FAR
6.302. Interested persons may identify their interest and capability
to respond to the requirement or submit proposals to NIST, Attn: Anne
McFarlane, Building 301, Room B117, 100 Bureau Drive Stop 3572,
Gaithersburg, MD 20899-3572. This notice of intent is not a request for
competitive proposals. However, all proposals received by 3:00 PM
Eastern Time January 13, 1999, will be considered by the Government. A
determination by the Government not to compete this proposed contract
based upon responses to this notice is solely within the discretion of
the Contracting Officer. NOTES: 1. This document must be created in
Word for Windows for use in CBDNet. 2. A complete list of
Classification Codes is on the Internet, reachable at the address:
http://cbdnet.access.gpo.gov/class.html 3. The office address in CBDNet
is automatic, therefore, any special addresses (other than our standard
office address) must be contained in the description. Posted 12/30/98
(W-SN284338). (0364) Loren Data Corp. http://www.ld.com (SYN# 0182 19990104\66-0002.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|