Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 17,1998 PSA#2244

Fleet and Industrial Supply Center, Puget Sound, Bldg 467 W Street, Code 200 Bid Desk, Bremerton, WA 98314-0051

34 -- MODULAR PANEL CONTAINMENT SYSTEM SOL N00406-99-R-5063 DUE 123198 POC Maureen Renville (360)476-7772 Self-framing modular panel system designed to form a containment enclosure for radiological and/or hazardous work control. Quantity of 2 each. Size: 24 feet long by 16 feet wide by 20 feet tall. Floor not required. To be designed to be sufficiently rigid to withstand a uniform internal negative pressure of 0.1 inches water column upon completion of erection. Capable of withstanding seismic forces for Zone 4. Enclosure roof shall be pre-engineered to span the 16ft width while supporting 1 man performing maintenance on roof mounted equipment. If needed, externally attached structural members shall be used to stiffen the roof as internal bracing or columns are not allowed. Panels shall feature interchange-ability of pre-engineered panel sections to allow assembly of various size containment buildings; shall have external structural frameworks of ordinary strength steel meeting ASTM A6 or A36; shall be sheathed on the interior with either stainless steel (ASTM A167 or A240 Type 304, 316, 304L or 316L stainless steel, cold rolled, annealed and pickled with a No. 2B or 2D finish on both sides and a minimum thickness of 22 gauge) or polycarbonate. Two panels having pre-hung personnel access doors each having a minimum clear opening of 30 in wide by 80 in tall supported by a minimum 16 gauge cold rolled steel framework integral with the panel framework. Door panels to be interchangeable with the other panels. Side walls to contain windows of clear, transparent polycarbonate sheets at least 0.125 in thick. Enclosure to be provided with a fabric rollup door having a nominal opening of 9 ft wide by 16 ft tall and provided with a suitably sized electric motor operator including an enclosed gearbox/brake assembly that operates on 460 Volt, 3-phase power. Door curtain shall be blue in color and made of a minimum 2-mm thick multi-ply PVC impregnated fabric. Additional specifications for doors will be found in the solicitation. Manuals containing detailed installation, field handling, erection and dismatlement instructions and detailed unit assembly/arrangement drawings shall be provided with the panels. A conceptual design including the general configuration, materials of construction and other data pertinent for the evaluation of the proposal to be provided with vendors proposal. Desired delivery is 60 days, required delivery is 90 days after effective date of contract. FOB Destination (1 ea) Puget Sound Naval Shipyard, Bremerton WA 98314 and (1 ea) to Naval Air Station North Island CA. Inspection/Acceptance will be at Destination. This requirement will be solicited using the policies contained in Part 12, Acquisition of Commercial items. A written solicitation will be issued. All responsible sources may submit offer/bid which shall be considered by Fleet & Industrial Supply Center, Puget Sound. Telephone requests will not be honored. Fax requests will be accepted at 360-476-2931. Posted 12/15/98 (W-SN280454). (0349)

Loren Data Corp. http://www.ld.com (SYN# 0207 19981217\34-0001.SOL)


34 - Metalworking Machinery Index Page