Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 18,1998 PSA#2183

Oc-Alc/Dir Of Contracting, 3001 Staff Dr Ste 1ag76a, Tinker Air Force Base Ok 73145-3015

J -- CONTROLLERS, TURBIN, PUMP SOL F34601-98-R-47361 DUE 110498 POC For copy, L. Corff/Lidab/[405]739-5460, For additional information contact L. Corff/Lidab/[405]739-5460 Services, Non-Personal: The contractor shall provide all labor, facilities, equipment and all material to accomplish OVERHAUL and MODIFY TO of Air Pressure Controllers, Cooling Turbine and Coolant Pump and packaging of the same. A Firm Fixed Price Requirements type contract is contemplated for One Year, plus four One-Year Options. The Items and Estimated Quantities (EQ) are as follows: CLIN 0001: NSN 1660-01-275-6785; P/N 2118572-2; OVERHAUL MODIFY TO: NSN 1660-01-345-1127; P/N 2118572-3 NOUN: Air Pressure Controller; APPL: E-3; Basic Year Qty: 18 Ea; Option I Qty: 25 Ea; Option II Qty: 21 Ea; Option III Qty: 22 Ea; Option IV Qty: 17 Ea. Material: Aluminum. Dimensions: 14"L X 7.8"W X 2.4"H. WGT: 8.2 lbs. Description and Function: Provides control for air pressurization of the cabin. CLIN 0002: NSN 1660-01-345-1127; P/N 2118572-3; NOUN: Air Pressure Controller; APPL: E-3; Basic Year Qty: 27 Ea; Option I Qty: 38 Ea; Option II Qty: 32 Ea; Option III Qty: 33 Ea; Option IV Qty: 26 Ea. Material: Aluminum. Dimensions: 14"L X 7.8"W X 2.4"H. WGT: 8.2 lbs. Description and Function: Provides control for air pressurization of the cabin. CLIN 0003: NSN 1660-01-162-5523; P/N 2204480-3-2 and/or NSN 1660-01-307- 9561; P/N 2204480-3-3 and/or NSN 1660-01-410-1410; P/N 2204480-3-4 OVERHAUL MODIFY TO: NSN 1660-01-410-1410; P/N 2204480-3-4 NOUN: Cooling Turbine; APPL: C-5B; Basic Year Qty: 30 Ea; Option I Qty: 30 Ea; Option II Qty: 30 Ea; Option III Qty: 30 Ea; Option IV Qty: 30 Ea. Material: Stainless Steel and Aluminum Alloy. Dimensions: 19"L X 11.5"W X 12.75"H. WGT: 21 lbs. Description and Function: Provides cooled air for the cabin and the avionics. CLIN 0004: NSN 4320-01-005-8116TP; P/N 580950-3-1 and/or P/N 580950-3-2 and/or P/N 580950-3-3; NOUN: Coolant Pump; APPL: E-3B/C; Basic Year Qty: 5 Ea; Option I Qty: 5 Ea; Option II Qty: 5 Ea; Option III Qty: 5 Ea; Option IV Qty: 5 Ea. Material: Steel and Aluminum. Dimensions: 13"L X 10"W X 9"H. WGT: 32.5 lbs. Description and Function: Pumps fluid through cooling loop. CLIN 0005: Over and Above Work: Basic year/Option I/Option II/Option III/Option IV. CLIN 0006: DATA IAW DD Form 1423. Basic year: Exhibit "A"; Option I: Exhibit "B"; Option II: Exhibit "C"; Option III: Exhibit "D"; Option IV: Exhibit "E". Deliveries are to be determined at the time of shipment. All shipments will be directed by the Production Management Specialist (PMS) via Fax or Email. Award may include Options. No telephone requests. Only written or faxed requests received directly from the requestor are acceptable. All responsible sources may submit a bid, proposal, or quotation which shall be considered. REPLY FAX NUMBER is (405)739-4417, ATTN: L.Corff. Qualification requirements: Sources must be qualified prior to being considered for award. The solicitation will contain instructions for obtaining further information on this requirement. The requirements of FAR 9.202(A) have been completed and copies of the qualification requirements and standards may be obtained as described in the solicitation. These qualification requirements apply to line item(s) 0001-0004 The approximate issue/response date will be 05 OCT 1998. To: Alliedsignal Aerospace Company, Torrance Ca 90504-6099. No telephone requests. Only written or faxed requests received directly from the requestor are acceptable. All responsible sources solicited may submit a bid, proposal, or quotation which shall be considered. Authority: 10 U.S.C. 2304(C)(1), Justification: Supplies (or Services) required are available from only one or a limited number of responsible source(s) and no other type of supplies or services will satisfy agency requirements. Note: An Ombudsman has been appointed to hear concerns from offerors or potential Offerors during the proposal development phase of this acquisition. The purpose of the Ombudsman is not to diminish the authority of the program director or contracting officer, but to communicate contractor concerns, issues, disagreements, and recommendations to the appropriate government personnel. When requested, the Ombudsman will maintain strict confidentiality as to source of the concern. The Ombudsman does not participate in the evaluation of proposals or in the source selection process. Interested parties are invited to call the Ombudsman at (405) 736-3273. DO NOT CALL THIS NUMBER FOR SOLICITATION REQUESTS. Note: Faxed solicitation requests can be submitted to OC-ALC/PKXDA, Tinker AFB OK 73145-3015, FAX NUMBER (405)739-5411. See Note (s) Note 26. Posted 09/16/98 (I-SN250724). (0259)

Loren Data Corp. http://www.ld.com (SYN# 0049 19980918\J-0023.SOL)


J - Maintenance, Repair and Rebuilding of Equipment Index Page