COMMERCE BUSINESS DAILY ISSUE OF AUGUST 28,1998 PSA#216950 CONS/LGCW, 66 Falcon Parkway, Suite 49, Falcon AFB, CO 80912-6649 J -- PREVENTATIVE MAINTENANCE AND EMERGENCY REPAIR OF GAS TURBINE
GENERATORS SOL FA2550-99-QY087 DUE 091598 POC Contract Specialist,
Raymond S. Tracey, (719) 567-3437, Contracting Officer, Michael
Wittkopf (719)-567-3456 E-MAIL: Contract Specialist,
traceyrs@Schriever.af.mil. (i) This is a combined synopsis/solicitation
for commercial items prepared in accordance with FAR Subpart 12.6, as
supplemented with additional information included in this notice. This
announcement constitutes the only solicitation: quotes are being
requested and a written solicitation will not be issued. (ii)
FA2550-99-QY087 is the solicitation number, the solicitation is issued
as a request for quotation (RFQ). (iii) The solicitation document and
incorporated provisions and clauses are those in effect through
Federal Acquisition Circular 97-04 and Defense Acquisition Circular
91-13. (iv) This acquisition is unrestricted. Standard Industrial Code
7699 applies, with a size standard of $5 million. (v) CLIN 0001. 40
man-hours $___________ Provide 24 (twenty-four) hour emergency service
on 11 (eleven) Solar Gas Turbine Generator Sets, mod T 1021S-21, 750
KW. CLIN 0002., 22 jobs $___________, Provide (one) year of annual
preventative maintenance, divided into 2 (two) semi-annual visits per
generator set as directed in Statement of Work. (vi) SECTION I --
GENERAL SCOPE OF WORK The vendor will provide preventative maintenance
and emergency repair service on 11(eleven) Solar Gas Turbine Generator
Units model T-1021S-21. Emergency response time shall be no more than
1(one) hour if declared an emergency. Urgent response time will be no
more than 2 (two) hours if declared urgent. Vendor will coordinate with
750 MSS/CEO (power plant) 2 (two) weeks prior to start of semi-annual
inspections/maintenance. Vendor will track semi-annual inspections to
insure approximate 6 (six) month intervals and separating each 6 (six)
month inspection by serial sets model T-1021S-21, Solar established
check lists and field service directives. No more than 1 (one) Turbine
generator unit will be taken out of service at one time. Power plant
technicians will assist with load bank operation, water/detergent wash
and generator maintenance. SECTION II -- MAINTENANCE TERMS The
contractor shall furnish all labor, tools, materials, and
transportation necessary to perform preventative maintenance
inspections during the period of this contract semi annually as
schedule between the point of contact and the contractor. Preventative
maintenance will be performed within the hours of 7:30 am to 4:30 pm.,
except federal holidays. Proof of performance to include: Purchase
Order Number, machine operator signature, and date of performance shall
be forwarded to the address in Block 15 of the standard form 1449 prior
to payment. Repairs required as a result of abuse, misuse, theft, fire
accident, or act of God (lightning, Flood, etc.) are excluded from
this maintenance agreement and repairs for such will be negotiated on
an individual basis under a separate order. The contractor will
immediately report damages or mechanical failure due to other than fair
wear and tear to the contracting officer. The contractor shall not
proceed with repairs without the prior written approval of the
contracting officer. Excluded services: Modification and/or additional
attachments to the present equipment shall not be included under the
terms and conditions of this agreement. All repairs are to be conducted
on site at the locations specified. If this not possible and the
equipment is to be removed from the base by the contractor, a
requisition and invoice/shipping document will be prepared by the
equipment custodian or their authorized representative as a receipt
before the contractor is permitted to take custody of the equipment. A
listing of personnel authorized to accept services against this order
should be furnished in a separate letter. SECTION III -- GOVERNMENT
PROPERTY The Air Force will provide all materials, repair parts,
filters, lubricants, oil, hoses, tubing, wire, terminals, connectors,
and hardware required to accomplish this contract. Intervening
replacement parts and services not included in the preventative
maintenance agreement are excluded from this order. Those parts and
services must be negotiated on an individual basis under a separate
purchase order or use of the government IMPAC Card. SECTION IV --
CONTRACTOR FURNISHED PROPERTY, EQUIPMENT & SUPPLIES The vendor shall
provide all tools, test equipment, calibration equipment and measuring
devices required to perform preventative maintenance repair on 11
(eleven) gas turbine generator units described as solar model
T-1021S-21 generator set installed at Onizuka AS in building 1004,
(power plant). ORIGINAL EQUIPMENT PARTS: The contractor shall provide
all parts associated with preventative maintenance. The contractor
shall ensure that all parts and materials used will be new and conform
to the original equipment manufacturer's specifications. Rebuilt
assembles or subassemblies may be used to repair the equipment if the
item is standard and it is a standard industry practice, and the
rebuilt unit carries the same warranty as a new assembly or
subassembly. SECTION V -- SPECIFIC TASKS V.1 SAFETY AND HOUSEKEEPING No
work shall be performed on energized circuits or equipment if it can be
avoided. All personnel must be made safety conscious at all times and
all safety requirements shall be strictly adhered to. 4160 VAC circuit
breakers respective to the generator to be inspected will be placed
into the out of service position, locked out IAW Air Force lock out/tag
out procedure before any electrical or mechanical work is performed.
Technician will assure equipment and work area around Turbine Generator
Unit is clean during and at the end of work or upon completion of
inspection. V.2 MECHANICAL and ELECTRICAL Pre-inspection, no load/load
data will be taken. T 5, T 7 temperature monitors and speed monitors
will be calibrated before engine data is taken. Special attention will
be directed at natural as liquid fuel, oil, PCD and water
lines/plumbing and will be inspected for leaks, chaffing, wear, or
exposure of fabric. All plumbing indicating such conditions shall be
replaced with factory replacement parts or fabricated from materials
drawn from the Onizuka A S Air Force Stock. All items requiring
lockwire, example circular connectors/cannon plugs, bolts, and screws
will be done in compliance with O and M manuals. Water wash compressor
cleaning will be accomplished, if pre-inspection load/no load data so
dictates a detergent compressor was will be accomplished Vendor will
accomplish borescope inspection on first engine inspection upon
commencement of this contract and there after at least once every 500
(five hundred) hours of engine operation IAW borescope inspection
procedure in section 4-6 of Solar maintenance manual for 750 kW gas
turbine generator sets. All electrical AC and DC control wire
connections will be inspected and torque tested in compliance with O
and M manual) including local control. NOTE: Special attention will be
given to acceleration schedule during natural gas starts after all
inspections have been completed. If not within specifications, natural
gas fuel control will be adjusted to obtain peak performance during a
turbine start sequence on a natural gas start. SECTION VI --
APPLICABLE PUBLICATIONS Maintenance instructions for Solar 750 kW gas
Turbine Generator Sets Maintenance manual for 750/800 kW electrical
machinery continuos and standby duty generators. Maintenance manual for
series 3200 Western Gear Box. Solar electrical drawing number 104213.
SECTION VII -- FACILITIES, N/A, SECTION VIII- REQUIRED REPORTS Loaded
data will be taken at 600 kW value either using OAS base Utility Load
or power plant load bank. Post inspection engine data will be acquired
utilizing same load and same parameters as for pre-inspection data.
Vendor will provide a "rough" written report and any recommendations
upon completion of inspection and an official report within 10 (ten)
working days after completion of inspection. Reporting for Service: The
contractor shall report to the property custodian prior to commencement
of any services described herein, and before leaving the service area.
After completion of work, the contractor shall obtain a signature on
their service ticket from the individual who accepts theservices.
Service ticket shall also state the order number, services performed,
date/time commenced and completed, equipment serviced, and printed name
and then signature of contractor representative who performed the work.
One copy of the competed and signed ticket shall be provided to the
individual accepting the services. The original service ticket shall be
attached to the invoice. SECTION IX -PAYMENT: Payment will be made
semi-annually in arrears upon completion of services, acceptance by the
government, and submission of properly prepared invoice to the
accounting and finance office address indicated in block number 18a of
Standard Form 1449. The property custodian is responsible for receipt
and acceptance of services for the government. This purchase order is
exempt from state and local taxes. A copy of this order shall serve as
evidence of such exemption in accordance with federal acquisition
regulation 29.305 (a)(2). (vii) Performance period for this contract is
1 October 1998 through 30 September 1998; all terms are FOB
destination, Onizuka, Air Station, Ca. (viii) The provision at
52.212-1, Instructions to Offers-Commercial Items, applies, (ix) with
the following evaluation factors: first, past performance, second,
price. Past performance is more important than price. The government
reserves the right to award an offeror other than the low priced
offeror. (x) Offerors must include with their offer a completed copy of
the provisions at FAR 52.212-3. Offeror Representation and
Certifications-Commercial Items, and DFARS 252.212-7000, Offeror
Representations and Certifications Commercial Items. Contractors can
obtain the Representations and Certifications via the web at
http://farsite.hill.af.mil ATTENTION: In accordance with DFARS
252.204-7004 you must be registered in the Central Contractor
Registration to be considered for award. The offeror shall provide its
DUNS or, if applicable, its DUNS+4 number with its offer, which will
be used by the Contracting Officer to verify that the offeror is
registered in the CCR database. Lack of registration in the CCR
database will make an offeror ineligible for award. Offerors and
contractors may obtain information on registration and annual
confirmation requirements by calling 1-888-227-2423, or via Internet at
http://ccr.edi.disa.mil (xi) The clause at FAR 52.212-4, Contract Terms
and Conditions-Commercial Items, applies. (xii) FAR 52.212-5, Contract
Terms and Conditions Required to Implement Statues or Executive
Orders-Commercial Items and Statutes or Executive Orders Applicable to
Defense Acquisitions of Commercial Items, applies to this
solicitation. Specifically the following clauses, are applicable to
this solicitation: FAR 52.203-6, Restrictions on Subcontractor sales to
the Government with Alternate I: 52.203-10, Price or Fee Adjustment for
Illegal or Improper Activity: 52.219-8, Utilization of Small Business
Concerns and Small disadvantaged Business Concerns: 52.222-26, Equal
Opportunity: 52.222-35, Affirmative Action for Special Disabled and
Vietnam Era Veterans: 52.222-36, Affirmative Action for handicapped
Workers; 52.222-37 Employment Reports on Special Disabled Veterans and
Veterans of the Vietnam Era; 52.222-41, Service Contract Act of 1965,
as amended: 52.222-42, Statement of Equivalent rates for Federal
Hires; 52.222-44, fair Labor Standards Act and Service Contract
Act-Price Adjustment; 52.222-47, SCA Minimum Wages and Fringe Benefits;
DFARS 252.225-7001,Buy American Act and Balance of Payments program.
Wage Determination No: 94-2079 REV (9) is applicable to this contract.
(xiii)N/A (xiv)N/A (xv)N/A (xvi) Quotations are due at 1:00 pm, local
time, on Tuesday 15 September, 1998, at 50 CONS/LGCI, 66 Falcon Pkwy
Suite 49, Falcon AFB Co 80912-6649. Fax responses are acceptable to FAX
719-567-3437, clearly marked for the attention of Raymond S Tracey.
Offer shall also include the pricing information required in (v) above,
as well as the representations and certifications required by (x)
above. The offer shall also include any warranty information that will
be provided with the offeror's product. The offeror must describe the
details of what it is offering. The offer is strongly encouraged to
also submit brochures or other commercial literature showing work of
the type desired by this solicitation which will clearly demonstrate
past performance information such as references of customers who have
previously purchased the offeror's products. The more information
provided, the better able the Government will be to judge the merits of
the offeror's proposal and select the best value for the Government.
(xvii) For information, call Raymond S Tracey at 719-567-3437 or fax
719-567-3438. Posted 08/26/98 (W-SN242228). (0238) Loren Data Corp. http://www.ld.com (SYN# 0054 19980828\J-0009.SOL)
J - Maintenance, Repair and Rebuilding of Equipment Index Page
|
|