COMMERCE BUSINESS DAILY ISSUE OF AUGUST 21,1998 PSA#2164FISC Norfolk Detachment Philadelphia,700 Robbins Ave.,Bldg.2B,
Philadelphia, PA 19111-5083 99 -- AUTOMATED SWEATING GUARDED HOT PLATE TEST SYSTEM SOL
N00140-98-Q-3806 DUE 082898 POC Point of Contact -- Thelma Campbell,
Contract Negotiator, 215-697-9669, Contracting Officer, Dennis Bilger,
215-697-9669 E-MAIL: Click Here To Contact The BID Officer,
SYNOPSIS@PHIL.FISC.NAVY.MIL. This is a combined synopsis/solicitation
for commercial items prepared in accordance with the format in FAR
subpart 12.6, as supplemented with additional information included in
this notice. This announcement constitutes the only solicitation;
quotations are being requested and a written solictation will not be
issued. Refer to solicitation as RFQ N00140-98-Q-3806. The soliciation
document and incorporated provisions and clauses are those in effect
through the Federal Acquisition Regulation dated 24 June 1997. The FISC
Norfolk Detachment Philadelphia intends to acquire on, full and open
competitive firm fixed price basis an Automated Sweating Guarded Hot
Plate Test System which shall comply with the following: able to test
in accordance with ASTM proposed test standard F23.60.05; system must
be a turn key device, only requiring an environmental test chamber for
proper operation; test plate surface shall be 10 inches by 10 inches
with a 5 inch surrounding guard plate; a system for feeding water to
both the test plate and guard plate test surfaces at a controlled rate
is required, the bucking heater plate can be utilized to pre-heat the
water to match test plate surface temperature; thermal electric
cooling or any other means shall be utilized to reduce bucking plate
temperature as required; separate and indepenent temperature control is
required for all three plate sections of the test system; data
acquisition shall be by Hewlett Packard Data Acquisition/Switch Unit;
system includes: pentium personal computer (PC), signal conditioning
electronic console, sweating quarded hot plate, air flow hood with
integral ambient temperature sensor, remote mounted humidity sensor,
and an anemometer that can control air flow in the hood by computer or
manual adjustment from 1.0 to greater than 2.5 meters per second wind
speed. FAR 52.212-1 is applicable. Note: offeror's attention is
specifically directed to paragraph (b)(11) of this clause. A statement
complying with this paragraph must be included in the quotation. FAR
52.212-4 is applicable. FAR 52.212-5 is applicable, along with the
following FAR clauses cited:52.203-6, 52-203-10, 52.219-8,
52.222-35,52.222-36 and 52.222-37. DFARS 252.212-7001 is applicable,
along with the following additional DFARS clause cited: 252.225-7012,
and 252.225-7036. All responsible sources may submit a quotation in
response to the solicitation which shall be considered by FISC Norfolk
Detachment Philadelphia no later than 8/24/98 at 4:00 pm local
Philadelphia time. Fax responses shall also be accepted. FAR 52.215-18
applies. Fax number (215) 215-697-9569 to the attention of code
02P41C. Posted 08/19/98 (D-SN238904). (0231) Loren Data Corp. http://www.ld.com (SYN# 0423 19980821\99-0007.SOL)