COMMERCE BUSINESS DAILY ISSUE OF AUGUST 20,1998 PSA#2163Defense Special Weapons Agency, Acquisition Office (FCA), 1680 Texas
St., SE, Kirtland, AFB, NM 87117-5669 44 -- MULTICELL HEATER SOL DSWA02-98-Q-0092 DUE 090498 POC Toni
Sandoval, Contract Specialist, (505) 846-8830/Patricia M. McDaniel,
Contracting Officer, (505) 846-8799 with Modifications: 1) Lead Strain
Relief, 2) Positive Ground on Thermowell; 20 each; Watlow Part No.
8945 "BRAND NAME OR EQUAL". Minimum salient characteristics for
Resistance Heater Rod with Tapered End -- Material: Incoloy 800 HT;
Electrical Performance: 10KW min power, 480V single phase; thermal
Performance: 1650 deg F operating temp. Capability for a minimum of one
thermo- couple to measure rod temperature. Screw lug or 20ft wire
termination. Notice the distinguished taper at the end of rod. Multicel
Heater: 0.935 diameter minimum x 218" OAL maximum, 168" heated length
(bottom section of rod). Operating Pressure: 2500psig at 1650 deg F
operating pressure for heater element and 1" tubing sleeve. Sleeve to
be installed at accommodate 1" com- pression fitting. Compression
fitting to be provided and installed by others. Weld/Pressure Testing:
Helium leak test required on sleeve for all elements. Pressure test
required for sampling of test sections to verify pressure. Award will
include a Basic Period with two one-year options for the purchase of 20
heater rods per year. Delivery shall be FOB Destination to Kirtland
AFB, NM 87117. A written Request for Quotation (RFQ) will be issued and
award will be accomplished using the Simplified Acquisition Procedures.
Request for RFQs may be faxed to: Toni Sandoval, (505) 846-4246. See
Note 1. All responsible sources may submit a quotation which will be
considered. ***** Posted 08/18/98 (W-SN238382). (0230) Loren Data Corp. http://www.ld.com (SYN# 0290 19980820\44-0001.SOL)