COMMERCE BUSINESS DAILY ISSUE OF AUGUST 10,1998 PSA#21556th Contracting Squadron, Attn: LGCX, 2606 Brown Pelican Ave., Macdill
AFB, FL 33621-5000 63 -- CHEMICAL WARFARE AGENT MONITORING SYSTEM SOL f08602-98-T2967 DUE
082198 POC TSgt Michael Worthington, Contract Administrator,
(813)828-3815 ext 315; Mr. David Chittenden, Contracting Officer, 6th
Contracting Squadron is soliciting proposal for Chemical Warfare Agent
Monitoring System. Hand-held chemical/Nerve Agent Detectors. (1) SAW
Minicad mk II (Surface Acoustic Wave Microsensors Miniature Chemical
Agent Detector) (QTY) 2 each. This is a personal, light weight, solid
state chemical agent detector. Simultaneously detect trace levels of
nerve and blister chemical agents. Must operate from either standard,
off-the-shelf lithium batteries or a rechargeable batter pack. Basic
features: fully automatic operation, compact, lightweight (1lbs),
portable, LED and audible alarms, 60 second cycle time, records data,
operating humidity 0 to 95%, non-condensing, requires no user
maintenance, standard warranty one year or 500 hours of use, parts and
labor and 5 years shelf life. (2) CW Sentry (Installed Chemical Agent
Detector) (QTY) 12 each. The CW Sentry is a compact instrument that
detects trace levels of chemical warfare agents. It is fully automatic
and is designed for fixed installations where 24hour-a-day monitoring
is required. The CW Sentry is designed for analyzing ambient air for
traces of CW agents, performing a sample analysis every 60 seconds.
This means of simple switch closures or an optional RS232C serial ASCII
communication line reports alarm concentrations. The CW Sentry can be
incorporated into existing fire detection systems. Features:
Simultaneously detects nerve and blister agents, Selective to specific
chemical agents to avoid false alarms, performs self-diagnostic
checks, Provides switch closure alarm signals. Warranty: 0ne year. (3)
Installation turn-key operation (no calibration) (4) Training 20
Personnel. Total of four line items. Developed by Microsensor Systems,
Inc, and Manufactured by: Analytix, Inc. SIC: 3812, 750. SOLE SOURCE.
Estimated issuance date of RFP F08602-98-T2967 is 14 Aug 98 and
responses are due to be received by 21 Aug 98. This requirement is to
be delivered 90 days ARO, although earlier delivery is requested. HQ
USSOCOM/COCS-SM 7701 Tampa Point Blvd. MacDillAFB, FL 33621-5000. FOB:
Destination, Acceptance: Destination. Posted 08/06/98 (W-SN233842).
(0218) Loren Data Corp. http://www.ld.com (SYN# 0363 19980810\63-0001.SOL)