Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JULY 17,1998 PSA#2139

Defense Supply Service-Washington, 5200 Army Pentagon, Rm. 1D245, Washington, DC 20310-5200

J -- MAINTENANCE DUE 073098 POC Contracting Officer, Joseph Spencer, 703-695-7303 WEB: DASWo1-98-Q-0001, http://cbdnet.access.gpo.gov. E-MAIL: SpencJE@hqda.army.mil, SpencJE@hqda.army.mil. This requirement will be for preventive and remedial maintenance to include repair parts and services to be performed during during both Principle Period of maintenance (PPM) and other Principal Periods of Maintenance(OPPM). Repair parts and services include labor, parts, tools, test equipment, and travel. Maintenance will be performed on the following government equipment:2 ea. York 70 ton back-up chiller units, Model YCAZ4LE3-17PC&17B,1 ea. Dunham Bush chiller, Model AU60A, Serial Number 7176201A92H, Test Pressure 400 PSIG high side/300 PSIG low side, Factor Order:717862-1, Attached to chiller unit A is:Air Handler, Model RT 38MF AHU-1, Serial Number 71783-01A92H, 150 PSI per minute pressure supply for 208 volts, horsepower 15FLA 41, control circuits 115 volts, location: Pentagon Roof(accessible through room 5A910)6 ea.Data Aire Nine(9) ton processed cooling units,Model DACD-01, ModelDACD-18321, Serial Number 90-166A, 208 volts, 3Phase, 60 HZ, VAP Blow Motor 1/7.5 HP, 20 FLA each, Minimum CircuitAmpality 25 amps, Location:four (4) units in Pentagon, 5B910, 8 ea. DATA AIRE Nine(9) ton processed cooling units, Model:DACD-08, ModelDACD-18321, Evaporator Blower1/3 Horsepower and 8.4 FLA each, MCA 11 AMP, MTDF 15 Locted in Pentagon, 2ea. LEIBERT, ten (10) ton processed cooling units Model: FH302C-C01 208 Volts, 3phase Hz input 98.8 Amps minimum supply circuit ampacity, Maximum circuit breaker 150 Amps FAN 5.0 horsepower, 208 Voolts, 3 phase, 60Hz, 60 FLA, serial number P09699 and P103353, Location Pentagon, Room 5B910, 2ea. TACO Water Booster Pumps, Model:FM2508 8.25, serial number:B2E1B1LO, CAP GMP 262 HD FT, Motor 7.5 horsepower, 1750 RPM Frame E, 2 ea. Baldor Motor Cat Water Booster Pumps (Back-up), Model:M3311T SPEC 37B01X54 FRAME 213T, Serial number F491, 460 volts, Amp, 3phase, 60 Hz Horsepower RPM, location Pentagon Room 5A910, 1ea. DUNHAM-BUSH pneumatic Control Panel, Model MOD RT.39 MF AHU-1, serial number 717863-01A92H, Supply Fan:Horsepower, 53 FLA 208 volts, 3 phase, 60 Hz, Supply Fan: horsepower, 53 FLA, 208 volts, 3 phase 60 Hz, Return Fan: Horsepower, 41 FLA, volts 3 phase, 60 HZ, Location Pentagon Room 5A910, DURHAM-BUSH Compressor and Peripheral Equipment, Model: AU60A, Test Pressure, 400 PSIG (high Side), 300 Low Side), Unit Volts: 200 volts, 3 phase, 60 Hz, Factor Order 717862-1, Continous volts: 115 Volts, single phase, 60 Hz, R-22 Compressor Motor, Unit Number 4DR13000 TXK/112.9 RLARA 470 200 volts, 3 phase, 60Hz 4DJ13000 TXk, Minimum Circuit Ampacity 281 Amps, Maximum Fuse size 350 Amps, Location Pentagon, Corridor Eight (8) Fan Room. The Pentagon Telecommunication Service Center operates 24 hours a day, 7 days a week, 365/366 days a year, to include all Federal and Government holidays, Government administrative, snow days, and days declared holidays by Presidential Executive Order. The period of performance of this requirement is for 12 months, commencing 01 October 1998 and ending 30 September 1999, with three (3) Option Years. Quote shall be be received by 10 a:m, 30 July 1998.**** Posted 07/15/98 (W-SN223495). (0196)

Loren Data Corp. http://www.ld.com (SYN# 0077 19980717\J-0025.SOL)


J - Maintenance, Repair and Rebuilding of Equipment Index Page