COMMERCE BUSINESS DAILY ISSUE OF JULY 17,1998 PSA#2139DOC; Mountain Administrative Support Center; Acquisition Management
Division; 325 Broadway MC3; Boulder, CO 66 -- COMPRESSOR FOR USE IN A CRYOGENIC REFRIGERATION SYSTEM SOL
NB838-801524DT POC Doris Turner, Purchasing Agent, 303-497-3872 or FAX
303-497-3163 E-MAIL: NOAA; MASC Acquisition Management,
Doris.P.Turner@noaa.gov. The National Institute of Standards and
Technology (NIST) requires a non-lubricated compressor for use in a
cryogenic refrigeration system. The following minimum requirements must
be met. 1. Volumetric flow rate of at least 12 slm. 2. High pressure of
at least 2.75 MPa. 3. Low pressure less than 0.1 MPa. 4. Electrical
input power from 110 VAC 60 Hz source. 5. Electrical input power not to
exceed 600 W. 6. Electronics must allow control of volumetric flow
rate. 7. No lubrication. 8. Air cooled. 9. Nitrogen working fluid.
Interested sources proposing to supply a compressor which meets these
requirements must submit a written quote and a qualification statement
clearly establishing capability to meet the above requirements within
15 days from the date of this synopsis. This simplified acquisition
will be based upon the best value to the Government, with technical
merit and past performance being significantly more important than
price. Terms and conditions and agency level protest procedures are
referenceat http://netsite.esa.doc.gov. No RFQ package is available.
Posted 07/15/98 (D-SN223610). (0196) Loren Data Corp. http://www.ld.com (SYN# 0553 19980717\66-0022.SOL)