Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MAY 15,1998 PSA#2096

Navy Public Works Center, 310 John Tower Road, Pensacola, FL 32508-5303

47 -- PROCUREMENT OF STEAM AND CONDENSATE SYSTEM SOL N65114-98-Q-K001 DUE 060898 POC Shelene Armacost Contracting Officer (850) 452-4615 Steam piping system for underground installation as follows: (a) 4"x37' steam line with 4 ea elbows, (b) 4"x50' steam line with 4 ea elbows, (c) 4"x160' steam line with 5 ea elbows, (d) steam condensate piping system for underground installation, 1-1/4"x60'line with 4 ea elbows (e) steam condensate piping system, for underground installation 2 "x37' condensate line with 4 ea elbows, (f) steam condensate piping system, for underground installation 1 x 160' line with 5 elbows and expansion loop, (g) pump, duplex, condensate receiver, return system, with 35 gallon cast iron receiver, combination float switch and alternator, 208v, 1 PH, 60 HZ., MAX HP. 1750 RPM motors, capacity of pumps shall be for 12 gpm. @ 20 PSIG discharge pressure.,(info provided in specs)., (h) pump, duplex, condensate receiver, return system, outdoor installation, with vertical pumps and tefc motors, 30" diameter x 36" deep cast iron 110 gallon cast iron receiver for inground installation in a 6" concrete pad. Combination float switch and alternator, each pump 208v, 1PH, 60HZ., max 3/4HP. 1750 RPM motors, capacity of pumps shall be for 15gpm. @ 20 PSIG discharge pressure. Vendor shall take field measurements (after award) verifying: (a) size, length and direction of system; (b) locations of manhole and /or valve boxes; obstacles that must be avoided along path; (d) other pertinent general information as noted on NAVFAC drawings number 5308028,5308035 and 5308036. For site visit please contact contracting officer phone 850-452-4615. A letter of acceptability issued by the Federal Agency Committee on Underground Heat Distribution Systems will be provided by the supplier. A letter signed by the representatives of Federal Agencies participating in the committee and stating that the suppliers system is approved for use for the site groundwater conditions, operating temperature and soil classification. After award and before fabrication all drawings and calculations shall be approved by code 400, Navy Public Works Engineering Department,Pensacola, FL. All drawings and calculations submitted by the vendor shall have a Professional Engineers stamp. Vendor to furnish shop drawings and details for installation of complete prefabricated Class-A steam system as per NAVFAC drawings number 5308028,5308035 and 5308036 (a) Prefabricated class-A steam and condensate system, system will be installed by NPWC workforce See note (1). All inquiries should be faxed to (850) 452-4615 (0133)

Loren Data Corp. http://www.ld.com (SYN# 0265 19980515\47-0003.SOL)


47 - Pipe, Tubing, Hose and Fittings Index Page