|
COMMERCE BUSINESS DAILY ISSUE OF MAY 12,1998 PSA#2093Contracting Officer (90C), Department of Veterans Affairs, North Texas
Health Care System, 4500 South Lancaster Road, Dallas, TX 75216 C -- INFRASTRUCTURE UPGRADE BLDG. 1, PROJECT #549-209 SOL RFP
549-92-98 DUE 061198 POC Joyce Cadwell, Contracting Officer, PH:
214-302-7535 Provide A/E Services for Project #549-209, Infrastructure
Upgrade, Bldg. 1, at the VA North TX Health Care System Dallas
Facility. Investigative, design and construction period services will
be provided for the addition of an attached multi-story service bay to
Building 1 and a secondary means of fire & safety exit/egress from
Building 1, 5th floor. Building 1 consists of a 1939 era, 6 story,
71,000 sf brick and concrete structure. Design will be reviewed by the
VA with comments and design input (historical requirements only) by
the Texas Historical Commission. Building 1 currently supports the
Medical Center's Mental Health Programs. The structure is in need of,
and sited for future total renovation. Existing systems (Mechanical,
Plumbing & Electrical) are totally inadequate to support current
patient or administrative requirements. Telephone/data risers have been
recently updated and will not require location within project space.
Work will include, but is not limited to architectural, structural,
mechanical, electrical, plumbing (MEP) and certain environmental
elements. In addition to registered professional architects and
engineers, the project design team shall include a Certified Industrial
Hygienist and Registered Fire Protection Engineer. CIH and RFPE may
function as consultants. Certified Industrial Hygienist shall insure
that all required asbestos design and abatement procedures along with
all other environmental conditions which might impact design
/construction (i.e. Underground Fuel Storage Tanks, UFST) are
incorporated in construction documents. RFPE shall be responsible for
design review and certification of all fire and safety design elements.
For purposes of continuity with existing station wide system, fire
alarm system design shall be designed based on the existing Cerberus
Pyrotronics master fire alarm system and in consultation with Cerberus
Pyrotronics Inc. design personnel. A/E shall possess a working
knowledge of VA standard specifications and design criteria. Design
shall be completed in within 180 calendar days after negotiated start
date, excluding governmental review time. Construction cost range is
between $1 and $2 million. Award is subject to the availability of
funds. A pre-proposal site visit will be required of the selected A/E
and consultants to familiarize them with the existing area and project
expectations. Drawings are to be produced on AutoCAD version 13 for
Windows NT and are to be dimensioned in both English and metric.
Specifications are to be produced in Microsoft Word 97 for Windows NT.
Construction period services are to include submittal / shop drawing
review, RFI's, Change Order Proposal review, IH monitoring and
reporting of asbestos abatement (if required), UFST or other project
environmental impact monitoring (if required), 6 general site visits
(if required) and as-built drawings. Firms must meet minimum
requirements before evaluation criteria will be applied. Minimum
requirements are stated herein and are repeated here for emphasis: MEP,
RFPE, CIH, Cerberus Pyrotronics as consultant; working knowledge of VA
standards and specs; hospital experience and located in Texas. Upon
meeting the minimum requirements, A/E selection will be based on the
following criteria and maximum point values are shown to reflect
relative importance: 1) Past performance which exhibits specialized
experience and technical competence in work to be performed, maximum 50
points; 2) Past performance which exhibits ability to design within
budgeted cost limitation and prepare accurate and highly detailed
construction cost estimates, max 50 points; 3) Past performance and
current work status which exhibits capacity to accomplish work in the
required time, max 50 pts; 4) Past performance and current methodology
pertaining to quality control methods used to ensure technical
accuracy of work, max 50 pts; 5) Professional qualifications of staff
and consultants, max 50 pts; 6) Past performance which demonstrates use
of recovered materials and energy efficiency, max 40 pts; 7) Experience
andcapabilities using CADD, max 25 pts; 8) Location of prime A/E and
consultants, max 25 pts. In accordance with P.L. 600-656, this
acquisition is NOT restricted to small or emerging-small businesses.
Standard Industrial Code 8711, Engineering Services, applies to this
acquisition and the small business size determination is NTE $2.5
million in average annual receipts over the preceding three fiscal
years. A/E firms, which meet the requirements of this announcement, are
invited to submit (1) Standard Form 254, Architect-Engineer and Related
Services Questionnaire, and (2) Standard Form 255, Architect-Engineer
and Related Services Questionnaire for Specific Project, IN FIVE
COPIES. Submission should be marked Attn: Joyce Cadwell (90C) at the
above address, and are due by 4:30 p.m. local time, 6/11/98. This is
not a request for proposals. (0128) Loren Data Corp. http://www.ld.com (SYN# 0020 19980512\C-0001.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|