COMMERCE BUSINESS DAILY ISSUE OF JANUARY 29,1998 PSA#2021Department of the Interior, U.S. Geological Survey, 345 Middlefield
Road,Mail Stop 285, Menlo Park, CA 94025-3591 43 -- BOOSTER AIR COMPRESSER SOL 98-4715-0004 DUE 021698 POC Maribel
Torres, (650) 329-4171 E-MAIL: Maribel Torres, Western Region,
mtorres@wr.usgs.gov. The U.S. Geological Survey (USGS) Menlo Park,
California inteds to place a purchase order for a Booster Air
Compressor, specifications: Must be able to accept the air produced by
our Sullair air compressor on our drill rig (1100 cfm/350 psi) as the
input air. Must convert the input air to discharge air having a
pressure of at least 800 psi on a continual basis. Must be mounted on
a heavy duty skid, with lifting eye and forklift pockets and have a dry
weight of less than 6000 pounds. The unit must be of a compact design
such that it can be carried by a medium size truck or trailer. Should
be powered by a Diesel Engine capable of providing the necessary
horsepower for operation at an economical rpm, and have a fuel tank of
at least 35 gallons capacity, with fuel gage mounted on tank. Booster
Compressor unit should be equipped with the following: Two-stage air
cleaner, full-flow oil filter, fuel filter, fuel-water separator, air
moisture separator, air pre-cooler and after-cooler. Safety shut downs:
low engine oil pressure, high coolant temperature, oil cooler
temperature, and air high discharge temperature, safety relief valves
for inlet and discharge air, by pass unloading valve, fan and belt
guard. Following gauges to be mounted on control panel: inlet air
pressure gauge, discharge air pressure gauge, discharge air temperature
gauge, water temperature gauge, engine oil pressure gauge, ammeter,
hour meter, tachometer, start/stop switch, keyed ignition. The unit
must have one 2-inch inlet valve and one 2-inch discharge valve with
check valve. Must have a heavy duty electrical system and battery. Must
have suitable high pressure hoses to connect with the drill rig
compressor outlet and back to the drill pipe airway. Unit must have a
fitted heavy duty canvas cover to protect the equipment during non-use
in the field and while shipping between islands. Other required items:
two (2) copies of the owners/operators manual, two (2) copies of
schematics of all systems and a listing of all parts and filters, a
list of recommended spare parts, four (4) ignition keys. Training: the
manufacturer, at a time mutually agreed upon, shall provide
in-the-field training to the USGS drill crew in Hawaii. The training
shall cover all operating and safety systems, setup and break down and
actual operation of the booster compressor while drilling. Training
shall be at least three days. (0027) Loren Data Corp. http://www.ld.com (SYN# 0163 19980129\43-0001.SOL)