|
COMMERCE BUSINESS DAILY ISSUE OF JANUARY 21,1998 PSA#2015Department of Veterans Affairs Medical Center, 1310 24th Ave., S.,
Nashville, TN 37212 66 -- LABORATORY EQUIPMENT SOL 626-22-98-jo DUE 021398 POC Jack Oakes
(90C) 615/327-5311 E-MAIL: Contracting Officer's E-Mail Address,
OAKES,CLARENCE_E_ JR@NASHVILLE.VA.GOV. This is a Notice Of Intent to
award a sole source contract to CYTYC Corporation for the CYTYC
ThinPrep 2000 Processor for use in our Cytology Laboratory. This system
must include at a minimum the ThinPrep 2000 processor; twelve month
warranty; ThinPrep training class for one cytotechnologist and one
pathologist; Gynecologic ThinPrep Pap test package with supplies for
500 tests (500 Gyn TransCyt clear filters, 600 vials of PreservCyt
Solution for the ThinPrep Pap test, 8, gross boxes of ThinPrep
Microscope slides, 600 Collection Devices); Non-Gynecologic PreservCyt
Solution (2 boxes of 50 vials); Non-Gyn TransCyt blue filters (1 box
of 100 blue filters); CytoLyt solution( 1 box of 4, 32oz bottles); and
ThinPrep Microscope slides (1 box of gross). Basic features of this
system are its capability to automatically prepare slides from
non-gynecologic samples such as urines, body fluids, fine needle
aspirates, etc., using proprietary dispersion, filtration and cell
transfer technologies. This dispersion action homogenizes the cell
population within the sample vial, breaks up mucus and large sheets of
cells while maintaining diagnostic clusters. The filtration process
produces a cleaner background for viewing the diagnostic cells then
automatically transfers a thin, uniform layer of cells on the glass
slide in a 20mm circle in an area ten times greater than that of known
cytocentrifugation methods, reducing the number of slides needed per
case. This Notice Of Intent is not a Request For Competitive Proposal
or Quotation and no solicitation document exists. Information received
as a result of this synoposis will be considered solely for the
purpose of determining whether to conduct a competitive procurement.
All responses received will be fully considered by this medical center
and they must furnish all descriptive literature and technical data
sheets necessary for the purchasing activity to determine whether the
product offered meets the salient characteristics/requirements of this
advertisement. Failure to provide this information will cause your
response to be rejected as nonresponsive. See Note 22 (0016) Loren Data Corp. http://www.ld.com (SYN# 0303 19980121\66-0009.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|