COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 21,1997 PSA#1977DOC; Department of Commerce, Mountain Administrative Support Center;
Acquisition Management Division; 325 Broadway MC3; Boulder, CO 66 -- SURFACE MAGNETIC PROPERTIES AND ANALYSIS SYSTEM SOL
NB814000804056JW POC Jacqueline Wright, Purchasing Agent, (303)
497-5282, FAX: 303-497-3163 E-MAIL: NOAA; MASC Acquisition Management,
Jacqueline S. Wright@noaa.gov. The National Institute of Standards and
Technology (NIST) has a requirement for a surface magnetic properties
preparation and analysis system to study advanced magnetic recording
materials. The system required by this solicitation shall have and/or
meet the following minimum requirements. The system shall be currently
operating and shall have proven results immediately available. Used
equipment is acceptable. The system shall be comprised of an ultra-high
vacuum (base pressure lesser than 1x10-10 Torr) mu-metal chamber with
thin film growth and analysis capabilities. These must include 2
electron beam deposition sources capable of depositing both transition
and rare earth metals. There shall also be a computer controlled
thickness monitor, residual gas mass spectrometer and an argon ion
beam-sputtering gun. The sample mount must be capable of 5 axis high
precision manipulation with temperature control from 100K to 3000K. The
sample analysis capabilities must include: spatially resolved secondary
electron spin analysis for all three spin components, low energy
electron diffraction, angle resolved Auger electron analysis, and
in-situ magneto-optic Kerr susceptometer. The chamber must also be
mounted in a frame with vibration isolation of better than 0.2 Hz and
the system must be fully computer automated. Interested sources must
submit a written qualification statement and must contain sufficient
information to clearly establish the ability to provide the necessary
equipment December 5, 1997. Responses must reference Synopsis No.
NB814000804056JW. This announcement/solicitation is being issued under
the Simplified Acquisition Procedures, FAR Part 13 (NTE $100,000.00)
and is not a request for quotes. The system must be currently operating
and has proven results in the analysis on ultra-thin magnetic films in
ultra-high vacuum. The award decision will be based upon the best
value to the Government, with technical merit, past performance and
availability being significantly more important than price. Terms and
Conditions and agency level protest procedures are referenced at
http://netsite.esa.doc.gov.oam. Technical questions can be directed to
Paul Rice at (303) 497-3841. In the absence of other qualified
sources, it is the intent of the Government to negotiate on a sole
source basis with Virginia Commonwealth University, Richmond, VA.
(0323) Loren Data Corp. http://www.ld.com (SYN# 0222 19971121\66-0010.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|