COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 3,1997 PSA#1922Immigration & Naturalization Service, Procurement Division, 425 I St.,
NW, Room 2208, Washington, DC 20536 N -- PROOF AND FUNCTION BULLET TRAP (PFBT) SOL NFU-7B-0074 DUE 090897
POC Joan Bennett (202) 514-2062 THIS IS A COMBINED
SYNOPSIS/SOLICITATION FOR COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH
THE FORMAT IN FAR SUBPART 12.6, AS SUPPLEMENTED WITH ADDITIONAL
INFORMATION INCLUDED IN THIS NOTICE. THIS ANNOUNCEMENT CONSTITUTES THE
ONLY SOLICITATION. BIDS ARE BEING REQUESTED AND A WRITTEN SOLICITATION
WILL NOT BE ISSUED. The INS has a requirement for an Electrical
Discharge Machine. The following Specs shall be included with the
Electrical Discharge Machine: 1. The EDM machine shall be of the die
sinking, ram configuration; have table dimensions of 20 x 14" +/- 2";
XYZ axis shall have travels of 12x8x8", +/- 1"; Z axis back slide
travel shall be 8", +/- 1"; work tank dimensions shall be 33x20x12",
+/- 1"; maximum electrode with shall be 130 lbs, +/- 10 lbs; maximum
part weight shall be 1000 lbs, +/- 100 lbs; machine shall provide two
doors for easy access to the work area; T-slot work table shall be
hardened and ground. 2. Machine shall provide a pulse generator;
process monitor shall have a process display and be integrated. 3.
Machine shall provide an integrated dielectric system; tank capacity
shall be 75 gal +/- 10 gal; Vendor shall provide dielectric fluid;
filter cartridges shall be disposable, long life paper filters; vendor
shall provide 3 additional disposable filters; machine shall have a
dielectric cooler; pressure, suction and pulsed flushing modes shall be
provided in the system. 4 Machine shall be equipped w/standard safety
features; machine shall be equipped with halon fire extinguisher;
machine shall have a fire detector in the work tank; machine shall
provide for continuous monitoring of the dielectric fluid level &
temperature; machine shall have a automatic depth stop that is set with
a micrometer screw. 5. Vendor shall provide all accessories required to
have a completely functional machine; accessories such as flushing
hoses, clamps & lighting shall be supplied; machine shall provide
magnetic bases. 6. Vendor shall provide a complete customer service
package. Vendor shall provide for delivery, unpacking, installation,
inspection and set-up of machine. Vendor shall adjust, test and start
the machine; Technology table shall be supplied by vendor; operating
and maintenance manual shall be supplied; vendor shall provide operator
training for 4 NFU personnel; The vendor shall offer a bi-yearly
service agreement to provide maintenance and repair to the machine. The
service agreement shall include all parts and labor. In addition,
agreement shall provide service within a 48 hour period of the service
request. 7. The machine shall provide a digital position display in
three axis, XYZ; display shall be capable of zero point setting for all
the point settings; display shall have a digital readout automatic
depth stop of the Z axis; XYZ axes shall be equipped with high
precision scales for a direct measuring system. (0241) Loren Data Corp. http://www.ld.com (SYN# 0080 19970903\N-0002.SOL)