COMMERCE BUSINESS DAILY ISSUE OF JULY 22,1997 PSA#1892Contracts Group, Bldg 588, Mail Stop 32, Naval Air Warfare Center
Aircraft Division, Patuxent River, MD 20670-5304 59 -- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS SOL
N00421-97-R-1428 DUE 080897 POC John R. Tomechko, Contract Specialist,
(301) 342-1825 ext. 152 E-MAIL: Tomechko_
John%PAX9@MR.NAWCAD.NAVY.MIL, Tomechko_John%PAX9@MR.NAWCAD.NAVY.MIL.
The Naval Air Warfare Center Aircraft Division (NAWCAD) requires an SWR
Bridge Kit to calibrate and maintain network analyzer systems. NAWCAD
intends to award a sole-source, fixed price contract to Amritsu-Wiltron
of Gaithersburg, MD 20879. The contract line item number and specific
requirements are: CLIN 0001 quantity 6 each, SWR Bridge Kit. The
minimum requirements for the VSWR kit is to provide the following
components allowing reflection measurements to be made with high
accuracy for type N and GPC-7 connectors: VSWR bridge (up to 2 bridges
may be used to meet the following specs); Directivity of 46 dB from 5
MHz to 2 GHz and 38 dB from 2 to 18 GHz; test port match of 21 dB 5
Mhz-2 Ghz, 10 dB 2-3 Ghz, 14 dB 3-4 Ghz, and 18 dB 4-18 Ghz; 0.5 W
maximum input power. The connector types are GPC-7 for test port and
type N female for input and output ports. Adapters for the bridge kit
must be GPC-7/N male and female with 1.02 VSWR. Open/shorts must equal
50 ohms; GPC-7; 50 ohm terminations (DC to 18 Ghz; 1 0.5 W maximum
input power) type N male and female; VSWR of 1.002+0.0026*f(GHz); 50
ohm offset terminations (DC to 19 GHz; 0.5 W maximum input power);
GPC-7; return loss of 20+0.5 dB to 1 GHz, 20+1.0 dB to 4 GHz, 20+1.5 dB
to 18 Ghz. All items to be delivered under this contract shall be
warranted for defects in manufacturing and workmanship for a period of
one year. If interested parties are capable of providing a product
with the same specifications, please provide descriptive technical
literature to John R. Tomechko at the address referenced in line 7 of
this synopsis. The offeror must provide sufficient technical
literature, documentation, etc. in order for the Government to make an
adequate technical assessment of the offer. Responses are due to John
Tomechko (25521Q) at Contracts, Bldg. 588, Suite 2, Naval Air Warfare
Center-Aircraft Division, 47253 Whalen Road, Unit 588, Patuxent River,
MD 20670-1463 by 2:30 P.M. Eastern Standard Time on 11 August 1997. For
questions regarding this action, contact John Tomechko at (301)342-1825
ext. 152. (0199) Loren Data Corp. http://www.ld.com (SYN# 0413 19970722\59-0010.SOL)