COMMERCE BUSINESS DAILY ISSUE OF JULY 8,1997 PSA#1882U.S. Department Of Transportation (RSPA) Office of Contracts and
Procurement (DMA-30), 400 7th Street, Room 8321, S.W., Washington, D.C.
20590 A -- RESEARCH & DEVELOPMENT -- NATIONAL PIPELINE MAPPING SYSTEM SOL
DTRS56-97-Q-0014 DUE 081197 POC Thomas H. Scott, III, (202) 366-4538
E-MAIL: Click here to contact the Contracting Officer via e-mail,
tom.scott@rspa.dot.gov. The U.S. Department of Transportation, Research
and Special Programs Administration (RSPA), Office of Pipeline Safety
(OPS) is issuing a Request for Quotations for services to which RSPA
intends to award up to six (6), firm fixed price, purchase orders using
the Simplified Acquisition Procedures of FAR Part 13. Note, OPS intends
to issue a subsequent Request for Quotations from State agencies for
Pilot Testing at a later date, quotations from State agencies are not
being solicited at this time. Any contractor able to meet this
requirement must demonstrate in writing by the closing date. All
responsible sources may submit a written quotation which will be
considered by the Agency. This notice is intended for competitive
purposes. You may E-mail the contracting officer at
tom.scott@rspa.dot.gov. Please include the following: Company name;
address; phone number, and E-mail address. NO PHONE CALLS ACCEPTED.
Faxed requests are acceptable. The fax number is (202) 366-7974. All
questions must be addressed in writing and will be answered in writing.
Awards will be made to the firm(s) whose offer provides the greatest
value to the Government, price, and demonstrated past performance.
Award(s) may be based on other than lowest overall evaluated cost. Two
copies of all proposals, for the following statement of work, should
be delivered to the following address, (fax/E-mail copies will not be
accepted): U.S. Department of Transportation, Research and Special
Programs Administration, Office of Contracts and Procurement (DMA-30,
Rm. 8321), 400 7th Street, S.W., Washington, D.C. 20590; Attn: Tom
Scott. Due date: August 11, 1997; -- 2:30 pm EST. BACKGROUND-STATEMENT
OF WORK: The Research and Special Programs Administration's Office of
Pipeline Safety (OPS) has a requirement for the pilot testing of the
creation, operation, and maintenance of a national repository for the
National Pipeline Mapping System (NPMS). The OPS is responsible for
administering a national regulatory program to assure the safe and
environmentallysound transportation of natural gas, liquefied natural
gas, and hazardous liquids by pipeline. 49 U.S.C. Section 60102
requires interstate gas pipeline facility owners or operators to
provide maps of their facilities to the governing body of each
municipality in which the pipeline is located. In addition, Section
60109 requires the OPS to adopt rules requiring hazardous liquid
pipeline operators to identify facilities located in a high-density
population area or an area that is unusually sensitive to environmental
damage if there is a hazardous liquid pipeline accident, to maintain
maps and an inventory of information about that pipeline, and to make
that information available to federal and state officials upon request.
A team, the Mapping Quality Action Team (MQAT) II, representing OPS,
Federal and State Agencies, and private industry was formed to analyze
various mapping alternatives and determine a cost-effective strategy
for creating a reasonably accurate mechanism for depicting the
transportation of natural gas and hazardous liquids via pipeline and
liquefied natural gas facilities. The mapping system being developed is
the NPMS. A national repository will be created to house and manage the
NPMS. The national repository will work in conjunction with state
repositories in compiling and managing the data. The MQAT team has
developed draft standards for the submission of data by operators and
standards for the national repository. The draft standard's documents
include: 1) STANDARDS FOR ELECTRONIC DATA SUBMISSIONS, 2) STANDARDS FOR
PAPER DATA SUBMISSIONS, and 3) STANDARDS FOR THE NATIONAL PIPELINE
MAPPING SYSTEM REPOSITORY. Therefore, OPS is requesting proposals,
including a written statement of experience, from all parties
interested in pilot testing the national repository for the NPMS. There
will be up to six (6) contractors selected to pilot as a national
repository. The pilot national repositories will receive data from
operators and participating pilot state repositories and will complete
tasks in accordance with the draft standards. Each pilot national
repository will receive data submissions from two (2) participating
pilot state repositories and (3) pipeline operators. Each submission,
to the pilot national repository, will include approximately ten (10)
to twenty (20) miles of pipeline and/or liquefied natural gas (LNG)
facilities, attribute data, and metadata. It is anticipated that each
pilot national repository will receive both hard copy and digital data
to process. Each pilot national repository will be required to
complete the steps listed in Task 1, Task 2, and Task 3. The contractor
will: Submit a work plan, within ten working days of receipt of this
order, that includes a detailed description of how each task (listed
below) will be performed, a detailed budget (breakout of labor hours
and other direct costs), and views on potential problems. Task
Descriptions: Task 1 "Repository: Electronic Data" -- Check the
electronic media, that contains the files, for viruses. If a virus is
detected, contact the operator. Determine if the Data Transmittal Form
is complete and meets the Standards for Electronic Data Submissions.
If incomplete or if there are questions, contact the operator. The
information from the Data Transmittal Form will have to be entered into
an electronic file, ie. Word, WordPefect, Excel, Lotus 1-2-3. The data
will have to be stored in an electronic format compliant with the
Federal Geographic Data Commission (FGDC) standards for metadata. The
format will be provided by OPS. If the operator submits hard copy
attribute data, determine if the data content meets the Standards for
Electronic Data Submissions. If not, contact the operator. The
attribute data will have to be entered into an electronic file, ie.
Excel, Lotus 1-2-3. The data will have to be stored in relational
database management system (RDBMS) tables as defined in the Repository
Standards. Download the data from the electronic media. Determine if
the submitted graphical data meets the Standards for Electronic Data
Submissions for format. If not, determine if the graphical file can be
easily modified to meet the standards. If not, contact the operator.
Determine if the submitted digital attribute file meets the Standards
for Electronic Data Submissions for format and content. If not, contact
the operator. Construct the attribute tables according to the
Repository Standard. Import the graphical file, the attribute file, and
the metadata file. Depending on the format of the submitted data and
the software used, different procedures will be needed to accomplish
this process. Review the metadata file and compare for accuracy with
the graphical file. Conduct a quality control (QC) process. Check the
digital file for projection, latitude/longitude, and North American
Datum (NAD). If the file does not meet the Standards for Electronic
Data Submissions, can the file be easily modified and used? If not or
if there are other discrepancies, contact the operator. If required,
project the graphical file to NAD83, using NADCON software, and
geographic coordinates. Link the graphical, attribute, and metadata
files according to the Repository Standards. QC that the linking worked
properly between the files. Set up the relates between the graphical
and attribute files. Query on lines and/or points to ensure that all
the data displayed from the related tables is the correct attribute
data for the selected features. Create line or point topology if
needed. Create a check plot, for each graphical file, for the operator
to QC. The plot is to include the pipelines and/or LNG facilities
overlaid with a digital line graph (DLG) file that will be supplied by
the OPS. The check plot should also include the Facility ID for each
line and/or point. Send to the operator for comments and corrections.
Incorporate operator modifications to either the graphical data or
Facility ID attribute values. Edit the contact data in the metadata
file according to the Repository Standards. Warehouse the operator
contact data in a related RDBMS table. If required, edgematch pipeline
segments, by Facility Name, with adjacent pipeline segments provided
by other pilot repositories. If required append the individual
graphical files, by Facility Name, into one graphical file. Create a
final plot of each pipeline, by Facility Name, overlaid with a digital
DLG file that will be supplied by the OPS. Task 1 "Deliverables" --
Document all processes performed on the graphical data, attribute data,
and metadata. Document the time required to perform each of the steps.
Document the problems encountered and how they were resolved. Document
the strengths and weaknesses of the Standards for Electronic Data
Submissions and the Repository Standards. Recommend modifications to
the documents. Provide to the OPS a report on the process documentation
and recommendations. Provide to the OPS copies of the original source
data and an electronic and hardcopy of the graphical data, attribute
data, and metadata processed. Task 2 "Repository: Paper Data" --
Determine if the submitted hard copy map meets the Standards for Paper
Data Submissions. If it does not meet the standard, determine why. If
the format is correct but there are questions regarding the
identification of the pipeline(s) or LNG facility, then contact the
operator for clarification. If the format is other than 7.5' quad, is
the map usable? Are there at least four geo-referenced control points
on the map? If so, an attempt should be made to use the submitted
map(s). If there are no geo-referenced control points or less than four
control points, notify the operator that the submission does not meet
the Standards for Paper Data Submissions. Check the electronic media
that contains the attribute table(s) for viruses. If a virus is
detected, contact the operator. Determine if the Data Transmittal Form
is complete and meets the Standards for Paper Data Submissions. If
incomplete or if there are questions, contact the operator. The
information from the Data Transmittal Form will have to be entered into
an electronic file, ie. Word, WordPefect, Excel, Lotus 1-2-3. The data
will have to be stored in an electronic format compliant with the
Federal Geographic Data Commission (FGDC) standards for metadata. The
format will be provided by OPS. If the operator submits hard copy
attribute data, determine if the data content meets the Standards for
Paper Data Submissions. If not, contact the operator. The attribute
data will have to be entered into an electronic file, ie. Excel, Lotus
1-2-3. The data will have to be stored in relational database
management system (RDBMS) tables as defined in the Repository
Standards. Determine if the submitted digital attribute file meets the
Standards for Paper Data Submissions for format and content. If not,
determine if the attribute file can be easily modified to meet the
standards. If not, contact the operator. Prior to setup and digitizing,
review the metadata file and compare for accuracy with the hard copy
map. Conduct a quality control (QC) process. If working with a copy of
a 7.5' quad, validate that the scale of the map is intact. QC the
accuracy of the submitted metadata with the hard copy map. Check the
NAD. If the submitted map is other than 7.5' quad, check for control
points in latitude/longitude, scale, NAD, and projection. If there are
any discrepancies, contact the operator. Digitize the paper maps.
Setup the computer system and secure the map on the digitizing board.
Register the map, trying to minimize the root mean square (RMS) error.
Record the RMS error attained for each map digitized. If, on the first
attempt at registering, the RMS error is greater than 25 feet (ground
units), re-register and attempt to attain a lower RMS error. If the
error remains high, digitize and record the RMS error. Digitize the
lines or points. In order to accurately capture the drafted line, the
digitizer should digitize the centerline of the drafted line and
capture the maximum number of shape points along the line. Coincident
digital lines are not allowed. For the point data, the digitizer should
capture the center of the points drafted. After digitizing the lines
and/or points into the system, QC to ensure that all lines and/or
points were captured digitally from the paper map. Create topology for
lines and/or points. Topology should be created utilizing the minimum
tolerance values, allowed by the software, for the process. Define the
graphics attribute table according to the Repository Standard. In the
graphical file, code the lines and/or points for the attributes
specified in the Repository Standard. This will allow the linking of
the graphical line and/or point data with the attribute data. If
needed, project the graphical file into NAD83 and geographic
coordinates; QC the graphical file to ensure that it projected
correctly. Display the graphical file and visually compare with the
source to check for obvious distortions due to a projection error.
Display the graphical file with adjacent graphical files to check for
spatial correctness. If there are projection or spatial correctness
errors, check the latitude/longitude control point values; if possible,
re-project the graphical file. If the errors are in the original
operator graphical file, contact the operator. Edit the graphical file
for corrections. Edit for overshoots, undershoots, missing data, and
misaligned data. Edgematch and rubber sheet to adjacent maps. The
contractor will devise a standard methodology for edgematching and
rubbersheeting maps and document this process. Link the graphical,
attribute, and metadata files according to the Repository Standards. QC
that the linking worked properly between the files. Set up the relates
between the graphical and attribute files. Query on lines and/or
points to ensure that all the data, displayed from the related tables,
is the correct attribute data for the selected features. Rebuild
topology. Create a check plot, for each graphical file, for internal
QC. The check plot is to include the lines and/or points and the
Facility ID value for each line and/or point. Overlay check plots with
the source and QC line and/or point work andverify the Facility ID
value against the original source. Corrections as needed. Create a
check plot, for each graphical file, for the operator to QC. The plot
is to include the pipelines and/or LNG facilities overlaid with a DLG
file that will be supplied by the OPS. The check plot should also
include the Facility ID for each line and/or point. Send to the
operator for comments and corrections. Incorporate operator
modifications to either the graphical data or Facility ID attribute
values. Edit the contact data in the metadata file according to the
Repository Standards. Warehouse the operator contact data in a related
RDBMS table. If required, edgematch pipeline segments, by Facility
Name, with adjacent pipeline segments provided by pilot repositories.
If required, append the individual graphical files, by Facility Name,
into one graphical file. Create a final plot of each pipeline, by
Facility Name, overlaid with a DLG file that will be supplied by the
OPS. Task 2 Deliverables -- Document all processes performed on the
paper maps, graphical data, attribute data, and metadata. Document the
time required to perform each of the steps. Document the problems
encountered and how they were resolved. Document the strengths and
weaknesses of the Standards for Paper Data Submissions and the
Repository Standards. Recommend modifications to the documents. Provide
to the OPS a report on the process documentation and recommendations.
Provide to the OPS copies of the original source data and an electronic
and hardcopy of the graphical data, attribute data, and metadata
processed. Task 3 "Repository: General" and Deliverables -- Analyze the
repository model and the transfer of paper and digital data between
operators, state repositories, and the national repository. Document
the strengths and weaknesses of the repository model. Analyze the
operational flow process of converting paper and digital data according
to the Repository Standards. Document the strengths and weaknesses of
the process. Analyze the physical model of the attribute data files.
Document the strengths and weaknesses of the process. Make software and
design recommendations on developing an attribute and metadata
templates for input by the operator and extract by the repositories.
Provide to the OPS a report on the analysis and recommendations. All
deliverables are due March 1, 1998. Award selection will be based on
the following criteria categories listed in relative order of
importance: 1) Experience in managing a large networked geospatial
database or other information repository with geographic information
systems (GIS) and metadata standards, 2) Experience in dealing with
U.S. oil/gas pipeline companies and their respective data records and
holdings, 3) Ability to process, digitize, project, and link attribute
data with digitized data, 4) Accessibility and knowledge of various
GIS packages and data conversions, 5) Abilities to perform data
validation, transaction auditing, version control, and quality checks,
6) Experience in merging digital geospatial databases into a single
data set, 7) Ability to provide confidentiality and security for this
data, 8) Accessibility to Internet with high bandwidth and high-server
capabilities; experience in the creation and maintenance of an
Internet website, 9) Ability to create and maintain large object and/or
relational geospatial databases, 10) Ability to adapt and implement
future technological changes in the areas of communications, computers,
and GIS. All proposals will address each of the above criterion's
categories, providing specific examples of recent specialized
experience and technical competence, not to exceed ten (10) pages in
length. In addition to this statement of experience, provide proposed
staffing with the names and experience/qualifications of each key staff
member, not to exceed 2 pages per resume. For a copy of the STANDARDS
FOR ELECTRONIC DATA SUBMISSION, STANDARDS FOR PAPER DATA SUBMISSION,
AND STANDARDS FOR THE NATIONAL PIPELINE MAPPING SYSTEM REPOSITORY, fax
or E-mail your request to the Contracting Officer. (0184) Loren Data Corp. http://www.ld.com (SYN# 0010 19970708\A-0010.SOL)
A - Research and Development Index Page
|
|