COMMERCE BUSINESS DAILY ISSUE OF JUNE 27,1997 PSA#187689th Contracting Squadron, 1419 Menoher Drive, Andrews AFB, MD
20762-6500 70 -- DIGITAL MATRIX, 48X48 PORTSYSTEM SOL FA4416-97-T2717 DUE 071197
POC Mrs. Lori A. Ray, Contracting Officer, 301-981-2365, SSgt. Craig
A. McIntosh, Contract Administrator, 301-981-2315 E-MAIL: click here to
contact the contract administrator, mcintosh.craig@EMH.AON.AF.MIL. This
is a combined Synopsis/Request for Quotation (RFQ) for commercial items
prepared in accordance with the format specified in FAR Subpart 12.6,
as supplemented with additional information included in this notice.
This announcement constitutes the only solicitation; offers are being
requested and a written solicitation will not be issued. The
solicitation document and incorporated provisions and clauses are those
in effect through Federal Acquisition Circular 90-41. Matrix, Digital
Cross-Point, 48 input by 48out ports, each port shall have 25
individual leads. Port connections shall be invisible to all port
signals (no signal change or disruption). Ports shall connect any one
input to any one output with optional port group connections, software
programmable. Port leads connected shall pass data, clocks,
transitions and voltage levels (i.e. 1VDC to 7 VDC voltage + or -) as
if dry contact (non-TDM) relay style. Port lead connection shall
provide full duplex capability for all signals, as a minimum, 1.RS-232
protocols 2. RS-422 protocols 3. RS-530 protocols 4. Mil Std 188-114
protocols 5. IEEE-488 protocols 6. Voltage clamping no lower than 7
VDC. The matrix shall be a self contained unit with dimensions not
exceeding 19" rack width, 20" height and 20" depth. The matrix shall be
controlled via separate connector. Control interface options shall meet
RS-232, RS-422 and IEEE-488 interface standards. Matrix control
protocol shall be in the form of an ASCII syntax. At a minimum,
commands shall be provided to connect port, delete port, verify port,
dump matrix status, and clear all connections. ASCII acknowledgments or
error codes shall be provided for every command sent. All ports shall
have external, individual DB-25 (female) connectors for a total of 96
connectors. No cable/port concentrator units shall be employed (TDM).
Software option to provide automated swap from faulty port to next good
port. The matrix shall include redundant power supplies. The front
panel shall have LED indicators for 1. Power on and 2. DC Voltages
within operational range, each voltage having it's own display. See
Numbered Note 1. All responsible sources may submit an offer which will
be considered. All correspondence should refer to FA4416-97-T2717.
(0176) Loren Data Corp. http://www.ld.com (SYN# 0366 19970627\70-0010.SOL)