COMMERCE BUSINESS DAILY ISSUE OF MAY 19,1997 PSA#1848HSC/YAK, 8107 13th St, Brooks AFB, TX 78235-5218 D -- NOTICE OF INTENT TO AWARD SOLE SOURCE PROCUREMENT FOR
MODIFICATION OF COMMERCIAL SOFTWARE AND RELATED HELPDESK SUPPORT SOL
F41624-97-Q-1000 DUE 053097 POC Janelle Larrison (210)536-5464 E-MAIL:
contracting officer, larrisonj@diamond.brooks.af.mil. This notice is
a reclassification of "special notice" submission 072100 dated 12 May
1997 to "presolicitation notice". No synopsis text has been changed.
The U.S. Air Force, Human Systems Center, Brooks AFB, TX, intends to
award a sole source purchase order for modification of commercial
software used in the AF Fitness Program and for related helpdesk
support. The required modifications will provide parity and
compatibility with Air Force proprietary software and include: 1)
Adjustment of the workload every two minutes during the workload
progression phase ILO of every minute. Workload progression phase to
last six minutes; total test length to be 14 minutes, remove logic for
extending test by one minute. A conversion table showing the
tbl_interval which will consist of : TestRecordID, Interval, Heart
rate, and Workload is available from the contracting office identified
herein. 2) Change all checks for variable heart rate and formulas to
use 5 BPM. 3) Change logic to compare the final 3 heart rates if last
2 heart rates exceed 5 beat variance; if any 2 heart rates of the final
3 heart rates have a variance less than or equal to 5 beats, then use
those 2 heart rates for the calculations. 4) Change the invalid/fail
determination to use revised factors and change the report reading for
invalids to read: "[Rank] [Name], [SSAN], your score does not meet the
Air Force minimum fitness standards of [nn] (estimated VO2max) and is
less than the Air Force fitness standard of [nn]". Delete specific
score in this case. 5) Workload changes for re-tests after invalid,
which affect workload, will be exactly +/- 0.5 kp. Ignore the formulas
for workload on any follow up test after an invalid and apply the
workload adjustment to the workloads of the previous test. 6) For
pass/fail calculations, if only one of the three final HRs is 125bpm,
show as a valid assessment, perform calculations on a final heart rate
of 125 bpm. 7) When invalid test is due to a true variable heart rate
make no adjustment to workload for retest. Adjust workload downward by
0.5 KP if heart rate is increasing throughout last 3 minutes of the
test and variance is > 5 bpm. 8) For variable or increasing HR <
125bpm increase workload (0.5kp) for retest. 9) Remove adjustment to
the VO2max "score". 10) When the heart rate of the last minute is
greater than the maximum heart rate but one of the previous 2 heart
rates is not greater than the maximum heart rate, calculate the score
based on the average heart rate. 11) Add 10, single-alpha, AFPC codes
for repeat failures to tblTestSubject. 12) Change all dates to use
4-digit year. Change all forms and reports to accept/show 4 digit year.
12) Develop import interface with Government proprietary fitness
software for modules developed in ASIMS to accomplish import. 13) Allow
IFPM to update/delete exemption information. Display warning message
before the update/delete screen. 14) Prevent FAM from testing the same
subject twice on the same calendar day. 15) Allow UFPM to import data
from more than one Unit, add extra entries to tblMyUnit, change
summary report selection criteria to allow selection of all or specific
units. 16) Prevent personnel data export to Government personnel data
system. 17) Replace AFSC Table with table using current AFSC list. 18)
Add screen message for reducing workload to .5 kp to show
simultaneously with heart rate warning message for tests aborted due to
high heart rate. 19) Changes shall not effect protocol 20) Force
referential integrity on RankID, TobaccoID. 21) Produce an Invalid
assessment report showing the Name of the subject with type/count of
invalids Allow IFPM to select with the same criteria as the summary
report. (Unit, installation, office, dates). 22) Set/reset retest date
whenever a report or form will be displaying the information. Allow
the IFPM to change the retest date. 23) Modify selection criteria
screens to look like the summary report selection screen. 24) Modify
summary report to add 6 additional categories of personnel test status.
25)Allow IFPM to change next test date. 26) Privacy ACT statement to
print on all reports containing SSAN information. 27) Perform Database
repair with initial log in of each day for all stations. 27) Add
database calculation: If average HR<125bpm then Calculate score with
125bpm Else Calculate score with average HR. 28) Four months of
technical support from 8:00 am to 4:00 p.m. PDT will be provided. 29)
100 CD copies of the upgrade, each with user literature, FOB San
Antonio. 30) Option for an additional 12 months of technical support to
be exercised at the discretion of the Government. All responsible
sources may submit a quotation, which if received within fourteen (14)
days after publication of this synopsis, will be considered by the
Government. Interested vendors who can furnish the required software
and support may submit a statement demonstrating that the capability of
the product offered meets the requirements synopsized above.
Substantiating technical or other descriptive literature must be
provided, if requested by the contracting activity. However, this is
notice of intent -- not a request for competitive proposals, the
Government intends to solicit and negotiate with only one source,
MicroFit, Inc., a small business. The Determination to solicit from
only one source is pursuant to FAR 13.106-2(a)(5), Only One Responsible
Source Is Reasonably Available for the Items Described Herein.
Quotations received will normally be considered solely for the purpose
of determining whether to conduct a competitive procurement. Responses
referencing RFQ number F41624-97-Q-1000 must be priced FOB destination
and include support and maintenance limitations and/or restrictions,
and delivery date. Responses may be faxed, (210)536-3392, attn: Cyndi
Munch or sent electronically to munchc@diamond.brooks.af.mil within 15
days of the date of publication of this notice (0135) Loren Data Corp. http://www.ld.com (SYN# 0026 19970519\D-0005.SOL)
D - Automatic Data Processing and Telecommunication Services Index Page
|
|