Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 9,1997 PSA#1820

Hagler Bailly Consulting, Inc., 1530 Wilson Boulevard, Suite 900, Arlington, VA 22209. An action for the USAID program.

52 -- ELECTRIC METERING EQUIPMENT SOL RFQ 4165-003-E1 POC Contact Point: Mr. Laurent Pommier, Manager, Hagler Bailly Consulting, Inc., Tel. 703-312-9816, Fax: 703-351-0342, e-mail: Ipommier@habaco.com. For a USAID project in Armenia, Hagler Bailly is seeking sources for the supply of electric metering equipment. Interested parties should contact Hagler Bailly by fax or e-mail to indicate their interest in receiving the complete request for quotation (RFQ), which will be made available no later than April 15, 1997. Copies of the RFQ will be issued on a first come first served basis. Only a limited number of copies are available. Offers will be due 30 days from RFQ issuance date. Following are INDICATIVE quantities and specifications. The scope, quantities and specifications of the actual RFQ may differ from these indications. 1) (3000) residential electric meters: 1-phase, 1-element, self-contained electro-mechanical kWh counter, 220 V, 50 Hz, maximum continuous electric current: 40 A, odometer-type, bottom connected (or socket-type plus shallow adapter), maximum overall depth: 6.25" 2) (500) commercial electric meters: 3-phase, 3-elements, self-contained electro-mechanical kWh counter, 220 V, 50 Hz, maximum continuous electric current: 150 A, odometer-type, bottom connected (or socket-type plus shallow adapter), maximum overall depth: 6.25" 3) (100) substation electric meters: 3-phase, 2-elements, transformer-rated electronic meter featuring TOU configuration and, as options, demand register and data logging, 100 V phase-to-phase, 50 Hz, maximum continuous electric current: 5 A, switchboard-type enclosure measuring less than 9" x 6" x 5" (H x W x D). If switchboard model is more expensive than bottom-connected model, bidder shall quote both. 4) Electronic meter programming interfaces, as required to program and read the above electronic meters. 5) Current transformers: 10 kV, dual-secondary for electric meter and protective relay, 5A output rating for both secondaries, 50 Hz, indoor, ratios: 20:5//5, 25:5//5, 50:5//5, 100:5//5, 150:5//5. Several types of dimensional requirements to be further specified in RFQ, all three types measuring less than 12" x 16" x 8" (H x W x D). 6) Current transformers: 6 kV, dual-secondary for electric meter and protective relay, 5A output rating for both secondaries, 50 Hz, indoor, ratios: 200:5//5, 300:5//5, 400:5//5. Several types of dimensional requirements to be further specified in RFQ, all three types measuring less than 12" x 16" x 8" (H x W x D). 7) Potential transformers: three-phase transformer, input: 10 kV, 50 Hz, dual-secondary: meter secondary at 100 V between phase in wye-configuration (100:1 ratio) and fault-detection secondary with three windings in series so that this single output shows 0 unless there is a phase-to-ground fault, indoor, maximum dimensions around: 18" diameter and 20" height. 8) Potential transformers: three-phase transformer, input: 6 kV, 50 Hz, dual-secondary: meter secondary at 100 V between phase in wye-configuration (60:1 ratio) and fault-detection secondary with three windings in series so that this single output shows 0 unless there is a phase-to-ground fault, indoor, maximum dimensions around: 18" diameter and 15" height. 9) Current transformers: 400V, primary-bar type, 50 Hz, indoor, ratios: 1000/5, 600/5, 400/5, 300/5, 200/5, preferred length of bus-bar segment: around 4.75" bolt-to-bolt. 10) Self-contained analog voltage panel meter: 500V, 50 Hz, indoor, approximately 4.5" x 4.75" (H x W). 11) Transformer-rated analog voltage panel meter, 7500V display, 100V input (ratio: 75:1), 50 Hz, indoor, approximately 4.5" x 4.75" (H x W). 12) Transformer-rated analog current panel meter, ratios: 1000/5, 600/5, 400/5, 300/5, 200/5, approximately 4.5" x 4.75" (H x W). 13) Three-position switches for the above current panel meters, panel type, three positions to include: I1, I2, I3. 14) Six-position switches for the above voltage panel meters, panel type, six positions to include: V10, V20, V30, V12, V23, V13. 15) One bench-type electric meter tester, for 1- and 3-element bottom-connected meters. 16) Portable clamp-on meters, measuring amps, voltage, and possibly power on 400V bus-bar systems (large clamp required). (0094)

Loren Data Corp. http://www.ld.com (SYN# 0196 19970409\52-0002.SOL)


52 - Measuring Tools Index Page