U.S. Army Tank-Automotive and Armaments Command, Acquisition Center (AMSTA-AQ-DS), Warren, MI 48397-5000

23 -- TRUCK, MOBILE SURGICAL/FIRST AID/EXAMINATION UNIT (PART 3 OF 4) POC POC: Louis Marchio (810) 574-7208 . Surgical Suite walls shall be white, abs theroplastic to allow full disinfectant cleaning without damage. Floor cross members shall be of adequate size to support body and payload without fracture or failure under all combinations of expected loading and shall conform to federal motor carrier safety regulation 393.84. Wood floor parts, including plywood, shall be treated, and surfaced with Armstrong or equal, heavy duty cushioned vinyl linoleum. The double entrance/exit door shall be provided with a full width aluminum safety platform with aluminum, stairs and handrails. This platform/stairway assembly, including handrails, shall be capable of being stored in the under-body storage compartment. Electrical system shall be in accordance with the national electrical code, (NEC) NFPA no. 70. The unit shall be wired to receive 4 wire, 200 amp, 120/240 volt, 60 Hertz (Hz), AC, single phase power from local power sources. Wiring shall include individual 120 volt circuits for heating and air conditioning, duplex 120 volt receptacles, individual 240 volt receptacles, one 50 foot, 4 wire lead-in cables, and two 100 foot, 120 volt, 20 amp lead-in cables for overnight operation of refrigerator(S). Lighting shall be of standard 1, 2, OR 4 tube fixtures, securely surface mounted on interior body ceiling within plastic diffuser panels, to provide a minimum light density of 75 foot candles at working heights in all parts of each area. Twelvevolt emergency dome lights shall be provided at each entrance/exit door and within each exterior body compartment. A 30 KW, 4-WIRE, 120/240 volt, 60 Hz, AC, single phase Onan or equal capacity generator shall be provided. The generator shall be powered by a liquidcooled Diesel engine. A generator compartment shall be located at the rear of the vehicle. exterior floodlights, in the quantity of four, 150 Watt, shall be provided for night illumination, and be installed on the curbside body exterior. Three 220 volt roof air conditioner/heaters shall be installed. A plumbing system shall be installed. A surgical operating Suite shall be provided, ANF include double swinging doors, a floor of antistatic linoleum, walls and ceiling made from marlite, an affiliated, or equal, model 311 minor surgical table, two operating lights, coat hooks, a Jackson kick bucket, a Harris, or equal, double-bowl stainless steel stand, an anethesia system which includes two-gas anethesia machines with ventilator, absorber, vaporizor, and gas svavenger, general supply cabinet with six drawers, stainless steel Mayo stand and I.V. pole, crash cart with three full-width drawers, nylon rollers, and full-width storage compartment at the bottom. The surgical operating Suite must also include an oxygen delivery system, one S&W, model 730, or equal, defilrillator, complete with high intensity, display, heart rate read-out, energy selector, lighted indicators, acoustic indications, manual/synchronized selector, ECG screen, ECG input, safety paddles, coiled cables, discharge tester, paper recorder, charger, Battery, ECG/telemetry output, and automatic screen freeze control. A wall mounted, double x-ray film viewer shall be furnished and installed, a gomco, or equal, surgical aspirator (suction) with catheters, collection bottle and stand, four hospital-type suction outlets with two quick-disconnect hospital suction systems, one wall mounted stop clock, Drug and supply cabinet, and one complete surgical kit. the surgical SE E NOTE: N/A. All responsible sources may submit an off er which will be considered. (0062)

Loren Data Corp. http://www.ld.com (SYN# 0216 19970306\23-0005.SOL)


23 - Ground Effect Vehicles, Motor Vehicles, Trailers and Cycles Index Page