COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 23,1996 PSA#1747NASA, George C. Marshall Space Flight Center, Procurement Office,
Marshall Space Flight CenterP12, Marshall Space Flight Center, AL
35812 Z -- REPAIRS TO HIGH PRESSURE PIPING SYSTEM SOL IFB MSFC 8-97-3 POC
Contact Chuck Hamlin, GP56-L, 205-544-0347/Contract Specialist, or
Harry B. Craig, GP56-I/Contracting Officer WEB: Internet Link to MSFC
Business Opportunities Page,
http://msfcinfo.msfc.nasa.gov/midrange/presol/notices/notices.html.
E-MAIL: Point of Contact, Charles.S.Hamlin@msfc.nasa.gov. This project
consists of providing labor, equipment, and all materials to perform
installation, cleaning, and testing of the following approximate
lengths of new XX STR C.S., stn. stl. valves, and auxillary hardware
for 5, 000 psig (34, 500 kPa) GN2 and 3, 500 psig (25, 000 kPa) air: 15
m of 15-mm tubing; 1130 m of 40-mm pipe; 800 m of 80-mm pipe; and 18 m
of 100-mm pipe -- Installation of the pipe will be above and below
grade, under roads and paved areas, and in open trenches; numerous
connections to existing facilities; removal of existing manholes and
construction of new manholes -- Worksite is the George C. Marshall
Space Flight Center, AL -- The standard industrial classification code
for this procurement is (1711) -- Period of performance is 360
calendar days -- Estimated price range is between $500, 000 and $1,
000, 000.00 -- Firms responding to this ad will be provided the
solicitation package with drawings and specifications -- No
solicitation packages will be issued 10 days prior to scheduled bid
opening -- Bid packages containing specifications and drawings are
available at the non-refundable cost of $50.00 -- Payment must
accompany the request and be made only in the form of a certified check
or money order -- Money orders or certified checks should be made
payable to "NASA Cashier MSFC, " and should be marked with the IFB
number - -- Personal and company checks are not acceptable -- The bid
opening date will be contained in the solicitation -- All requests for
the solicitation package must be in writing -- This is a Small
Business Set-Aside -- An ombudsman has been appointed to hear concerns
from bidders, potential bidders, and contractors during the preaward
and postaward phases of this acquisition -- The purpose of the
ombudsman is not to diminish the authority of the contracting officer
or the selection official, but to communicate concerns, issues,
disagreements, and recommendations of interested parties to the
appropriate Government personnel and to work to resolve them -- When
requested, the ombudsman will maintain strict confidentiality as to the
source of the concern -- The ombudsman does not participate in the
evaluation of bidders, the source selection process, or the
adjudication of formal contract disputes -- Interested parties are
invited to call the installation ombudsman, Susan M. Smith at
205-544-0012 -- Concerns, issues, disagreements, and recommendations
which cannot be resolved at the installation may be referred to the
NASA ombudsman, Thomas S. Luedtke at 202-358-2090 -- Before consulting
with any ombudsman, interested parties must try to resolve their
concerns with the contract specialist or the contracting officer -- DO
NOT CALL THE OMBUDSMAN FOR SOLICITATION REQUESTS/INFORMATION. (0354) Loren Data Corp. http://www.ld.com (SYN# 0116 19961223\Z-0017.SOL)