|
COMMERCE BUSINESS DAILY ISSUE OF JULY 29,1996 PSA#1646FLEET & INDUSTRIAL SUPPLY CENTER, NORFOLK ACQUISITION GROUP, HAMPTON
ROADS DETACHMENT, PROCUREMENT DIVISION CODE 2029.07, 1968 GILBERT ST.,
STE 600, NORFOLK, VA 23511-3392 65 -- MEDICAL EQUIPMENT AND SUPPLIES SOL N00189-96-Q-4404 DUE 080796
POC D.R. CABARRAS, LEAD PURCHASING AGENT, 757-444-4941; (FACSIMILE
NUMBER: 757-444-4755) All P/Ns referenced are International Biomedical
Inc. 20 H Transport System, 110v/60hz, Configuration included with
Transport Syst Standard Chamber W/4 Tubing Grommets, front door W/ 2H
and parts and door stop kit, ventilator air, oxygen, valve assy, part
number 731-0400, 1 each; Accessory Module, detachable tall profile,
part number 731-0700, 1 each; Air/Oxy Cart for 9 Large Cylinder,
detachable ''Old Style'' Air/Oxy Cart for 2 Cylinders, part number
731-0220, 1 each; Skin Temperature Probe, regulates infants
temperature, part number 700-3409, 1 each; MVP-10 Ventilator Breathing
Apparatus to assist newborns in breathing, part number 731-9000, 1
each; Blender, Mounting Bracket, Internal Plumbing used with the
ventilator, part number 731-9115, 1 each; Oxygen Flowmeter, regulates
the flow of oxgen to the newborn, part number 731-9130, 1 each;
Neonatal Bag and Block, part number 731-9730, 1each; Magnahelic
Manometer, guage with numbers to give oxygen reading, part number
731-9970, 1 each; Corometrics 506 Monitor, Monitoring System, part
number 731-9020, 1 each; Corometrics Skin Temp Probe 5301A, part number
731-9222, 1 each; Corometrics Patient Cable 1408AAO, part number
731-9221, 1 each; Corometrics Lead Set 5109AAO, part number 731-9222,
1 each; Corometrics Interconnect Cable, part number 731-9656, 1 each;
Nonin Pluse Oximeter 8600, monitor that gives oxygen saturation in
blood, part number 731-9214, 1 each; Nonin 8008 Reuseable Infant Flex
Sensor, part number 731-9215, 1 each; Nonin 8800 I Patient Interface
Cable, part number 731-9655, 1 each; CAS 901 Blood Pressure Monitor,
part number 731-9080, 1 each; Mauna LOA Humidifier, humidifies air,
part number 731-9760, 1each; Case Of Simplex Breathing Circuits, part
number 731-9061, 1 each; Pediascan Tranilluminator Model, assists in
visualizing newborn veins in light, part number 731-9955, 1 each;
Termal Cover Standard Infant Chamber, part number 731-9590, 1 each;
Miniox III Oxygen Analyzer with Mounting Bracket, part number 731-9470,
1 each; Suction Unit with Regulator, suction device with guage, part
number 731-9090, 1 each; Air regulators with 90 Deg. Elbows and
Couplers for large cylinder, part number 731-9380, 1 each; Oxygen
Regulators with 90 Degree Elbows and Coulpers for large cylinders, part
number 731-9390, 1 each; Air Quick Connects-OHMEDA Style, part number
731-9306, 2 each; Oxygen Quick Connects-OHMEDA Style, part number
731-9307, 2 each; Air Steel Large Cylinder, part number 731-9240, 1
each; Oxygen Large Steel Cylinder, part number 731-9250, 1 each; Velcro
Line Straps, part number 731-9810, 2 each; Baxter AS40A Auto Syringe
Pump with brackets, part number 731-9042, 2 each; FOB DEST; Deliver to
VREP Contractor, NAS Bldg. LP-117, 8349 Air Cargo Road, Norfolk, VA;
Delivery Date: 26 Sep 96. All responsible sources may submit an offer
which shall be accepted. Requests for the solicitation must state that
neither the requestor nor principal corporate officials and owners are
currently suspended, debarred, or otherwise ineligible to receive
contracts from any Federal Agency. Failure to so represent will be
grounds for refusing the request. Reference RFQ N00189-96-Q-4404 when
requesting copies of the solicitation. (0207) Loren Data Corp. http://www.ld.com (SYN# 0401 19960726\65-0001.SOL)
65 - Medical, Dental and Veterinary Equipment and Supplies Index Page
|
|