Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JULY 24,1996 PSA#1643

16th Contracting Squadron, 350 Tully Street, PO Box 9190, Hurlburt Field FL 32544-9190

54 -- MODULAR IN-PLANT OFFICE SOL F08620-96-T3846 DUE 080296 POC TSgt Joni Norman, Contract Specialist, 904-884-3265. This is a combined synopsis/solicitation for commercial items prepared in accordance with format in FAR subpart 12.6 as supplemented with additional information included in this notice. Quotations are being requested, and a written solicitation will not be issued. This solicitation is hereby issued as a Request for Quotation (RFQ) F08620-96T3846. This RFQ incorporates the provisions and clauses as those in effect through Federal Acquisition Circular Number 90-36. This requirement is being advertised as full and open competition, and the standard industrial classification code is 5039; small business standard is 500 employees. SCHEDULE: The contractor shall provide all of the following items required for complete installation. Office size shall be approximately 16'x 42'x 17'. 1st floor ceiling shall be approximately 9'high, 2nd floor ceiling shall be approximately 8' high. ALUMINUM EXTERIOR/VINYL COVERED HARDBOARD INTERIOR WALLS (AB): The perimeter walls shall be approximately 3'' composite sandwich panels. The outside shall be stucco-embossed .024'' aluminum, pre-painted beige. The inside shall be approximately 1/8'' hardboard with a vinyl finish of oak. The resultant structural panel shall not require support columns every 4'. STEEL DECK/DROP CEILING - 2ND FLOOR: The roof shall consist of galvanized steel internesting pans as a dust cover with closure fascia; and a complete Class A 2' x 4' lay-in acoustical type drop ceiling system, complete with all hanging hardware, including pre-coated white steel main tee, cross tee, wall angle, and fiberglass white vinyl faced tiles approximately 5/8'' thick. 2 - STORY OFFICE - 24' MAXIMUM SPAN: Consists of 18GA galvanized steel reinforcing channels laminated into the length walls, as well as 14GA steel columns that are dropped into each panel joint. Beam support clips will be supplied as well as pre-drilled beams. The support clips are bolted through the reinforcing channels and tubular columns, as well as a back plate, at each panel joint. The beam is then hoisted into place and tightened. Sub-floor adhesive is put along all beam flanges and top channel, then approximately 1-1/8'' APA Tongue & Grove (T&G) plywood flooring is fastened to the beams and the flooring. The APA flooring has a sheet of galvanized steel laminated to the bottom of it. TEK fasteners are used to fasten the plywood to the beams and top channel. Total maximum distributed load is 100#PSF. All hardware is to be provided (bolts, nuts and washers are all ASTM A325). All steel is prime coated. 1/2 GLASS 3-PLY DOOR AND FRAME UNITS: (6ea) - 3' x 6'8'' x 1-3/4'', 3 ply type B-3G (1/2 glass) door and frame units are included. Both facings shall be approximately .024'' stucco-embossed aluminum, pre-painted beige to match the exterior wall. The door frames shall be extruded aluminum, .093'' thick minimum, and come complete with all fasteners and vinyl weatherstripping. Door includes 1-1/2'' pair hinges,key-in-knob lock, heavy duty door closure and 3/16'' clear tempered glass, glazed into the opening. PICTURE WINDOW - STANDARD: (17ea) - Picture windows are nominal 4'wide x 3' high. They are installed 42'' off the floor, glazed with 3/16''clear tempered glass; and built into wall panel. They are non-opening, and the entire window frame is finished in a 201-r1 clear anodize. HORIZONTAL SLIDING WINDOW: (6ea)- Horizontal sliding windows are nominal 4'wide x 3' high. They are installed 42'' off the floor, glazed with 1/8'' tempered clear glass; and built into wall panel. One side is stationary, the other half slides to the side, and they shall have an integral locking mechanism with cam latch and keeper. The entire window frame is finished in a 201-R1 clear anodize. STAIRWAY: One stairway shall be 32'' wide x 8'6'' high (nominal),includes a 3'6'' x 3'9'' landing, and railings. All members are pre-drilled, and all steel is prime coated. All steel is ASTM A36. NOTE: Stair treads shall be formed steel plate, prime coated (tread is 9-3/4'' wide and rise between treads in 8''). COMPLETE STAIR ASSEMBLY MUST MEET OSHA 29 CFR 1910.24 REQUIREMENTS. AIR CONDITIONER -COOLING & HEATING: (7EA) - Air conditioners shall be reverse cycle type that provide approximately 6800 BTU'S COOLING AND 6000 BTU's heating. The unit is a through-the-wall type, and panel preparation in required. The unit is 115v. ELECTRICAL PACKAGE -CONCEALED: The electrical package shall consist of 1/2'' EMT concealed in the panel and attached to flush mounted 2 x 4 boxes at receptacle and switch locations; (7ea) wall switches: (39ea) duplex receptacles; (39ea)quadruplex receptacles; (26ea) phone fixtures; (32ea) fluroescent fixtures (100fc at desk height); 100 AMP, 120/240v breaker box (12 double/24 single) and breaker(s). This package must meet NEC (current edition). All required connectors, fasteners, materials and installation instructions for complete assembly shall be included. NOTE: installation cost should be included as a separate line item. Quotation should include costs for FOB destination to Hurlburt Field, Fl. Warranty information, to include period and coverage, shall be stated. Availability/projected delivery time after receipt of order should be provided. FAR 52.212-1, Instructions to Offerors-Commercial, applies. IAW FAR 52-212-2, Evaluation-Commercial Items, the Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The Government anticipates the award of a firm-fixed price purchase order. The following factors (in descending order on importance) shall be used to evaluate offers: (i) technical capability of the item offered to meet the Government requirement; (ii) past performance, (iii) delivery time, (iv) price (including FOB destination charges). Technical capability, past performance, and delivery time, when combined, are 50% of the evaluation factor. Quotations should be submitted in sufficient detail to be used in evaluation of the offers. For evaluation of past performance, offerors are required to submit information pertaining to previous sales to other government activities or to private companies. Include contract number, date of purchase, amount of purchase, and name/address/phone number of purchaser. Failure to submit this information for evaluation will result in subpar scoring in the applicable area of evaluation. Offerors should include a completed copy of the provisions a FAR 52.212-3, Offeror Representations and Certifications-Commercial Items, with its offer. The FAR clauses at 52.212-4, Contract Terms and Conditions-Commercial Items, 52.212-5, Contract Terms and Conditions Required to Implement statues or Executive Orders-Commercial Items, 52-222-37, Employment Reports on Special Disabled Veterans and Veterans of the Vietnam Era, 52-225-18, European Community are incorporated by reference. DFARS 252.225-7001, Buy American Act and Balance of Payment Program is incorporated by reference. For a copy of the layout please call TSgt Joni Norman at (904)884-3265. All questions should be directed to: TSgt Joni Norman, (904)884-3265. Quotations should be submitted to 16 CONS/LGCS, Attention TSgt Joni Norman, PO Box 9190, Hurlburt Field, Fl 32544-9190 or faxed to (904)884-5372, Attention: TSgt Joni Norman, to arrive not later than 2 August 1996. See Numbered Note(s): 1. (0204)

Loren Data Corp. http://www.ld.com (SYN# 0370 19960723\54-0001.SOL)


54 - Prefabricated Structures and Scaffolding Index Page