COMMERCE BUSINESS DAILY ISSUE OF JULY 24,1996 PSA#164316th Contracting Squadron, 350 Tully Street, PO Box 9190, Hurlburt
Field FL 32544-9190 54 -- MODULAR IN-PLANT OFFICE SOL F08620-96-T3846 DUE 080296 POC TSgt
Joni Norman, Contract Specialist, 904-884-3265. This is a combined
synopsis/solicitation for commercial items prepared in accordance with
format in FAR subpart 12.6 as supplemented with additional information
included in this notice. Quotations are being requested, and a written
solicitation will not be issued. This solicitation is hereby issued as
a Request for Quotation (RFQ) F08620-96T3846. This RFQ incorporates the
provisions and clauses as those in effect through Federal Acquisition
Circular Number 90-36. This requirement is being advertised as full and
open competition, and the standard industrial classification code is
5039; small business standard is 500 employees. SCHEDULE: The
contractor shall provide all of the following items required for
complete installation. Office size shall be approximately 16'x 42'x
17'. 1st floor ceiling shall be approximately 9'high, 2nd floor ceiling
shall be approximately 8' high. ALUMINUM EXTERIOR/VINYL COVERED
HARDBOARD INTERIOR WALLS (AB): The perimeter walls shall be
approximately 3'' composite sandwich panels. The outside shall be
stucco-embossed .024'' aluminum, pre-painted beige. The inside shall be
approximately 1/8'' hardboard with a vinyl finish of oak. The resultant
structural panel shall not require support columns every 4'. STEEL
DECK/DROP CEILING - 2ND FLOOR: The roof shall consist of galvanized
steel internesting pans as a dust cover with closure fascia; and a
complete Class A 2' x 4' lay-in acoustical type drop ceiling system,
complete with all hanging hardware, including pre-coated white steel
main tee, cross tee, wall angle, and fiberglass white vinyl faced tiles
approximately 5/8'' thick. 2 - STORY OFFICE - 24' MAXIMUM SPAN:
Consists of 18GA galvanized steel reinforcing channels laminated into
the length walls, as well as 14GA steel columns that are dropped into
each panel joint. Beam support clips will be supplied as well as
pre-drilled beams. The support clips are bolted through the reinforcing
channels and tubular columns, as well as a back plate, at each panel
joint. The beam is then hoisted into place and tightened. Sub-floor
adhesive is put along all beam flanges and top channel, then
approximately 1-1/8'' APA Tongue & Grove (T&G) plywood flooring is
fastened to the beams and the flooring. The APA flooring has a sheet of
galvanized steel laminated to the bottom of it. TEK fasteners are used
to fasten the plywood to the beams and top channel. Total maximum
distributed load is 100#PSF. All hardware is to be provided (bolts,
nuts and washers are all ASTM A325). All steel is prime coated. 1/2
GLASS 3-PLY DOOR AND FRAME UNITS: (6ea) - 3' x 6'8'' x 1-3/4'', 3 ply
type B-3G (1/2 glass) door and frame units are included. Both facings
shall be approximately .024'' stucco-embossed aluminum, pre-painted
beige to match the exterior wall. The door frames shall be extruded
aluminum, .093'' thick minimum, and come complete with all fasteners
and vinyl weatherstripping. Door includes 1-1/2'' pair
hinges,key-in-knob lock, heavy duty door closure and 3/16'' clear
tempered glass, glazed into the opening. PICTURE WINDOW - STANDARD:
(17ea) - Picture windows are nominal 4'wide x 3' high. They are
installed 42'' off the floor, glazed with 3/16''clear tempered glass;
and built into wall panel. They are non-opening, and the entire window
frame is finished in a 201-r1 clear anodize. HORIZONTAL SLIDING
WINDOW: (6ea)- Horizontal sliding windows are nominal 4'wide x 3' high.
They are installed 42'' off the floor, glazed with 1/8'' tempered clear
glass; and built into wall panel. One side is stationary, the other
half slides to the side, and they shall have an integral locking
mechanism with cam latch and keeper. The entire window frame is
finished in a 201-R1 clear anodize. STAIRWAY: One stairway shall be
32'' wide x 8'6'' high (nominal),includes a 3'6'' x 3'9'' landing, and
railings. All members are pre-drilled, and all steel is prime coated.
All steel is ASTM A36. NOTE: Stair treads shall be formed steel plate,
prime coated (tread is 9-3/4'' wide and rise between treads in 8'').
COMPLETE STAIR ASSEMBLY MUST MEET OSHA 29 CFR 1910.24 REQUIREMENTS. AIR
CONDITIONER -COOLING & HEATING: (7EA) - Air conditioners shall be
reverse cycle type that provide approximately 6800 BTU'S COOLING AND
6000 BTU's heating. The unit is a through-the-wall type, and panel
preparation in required. The unit is 115v. ELECTRICAL PACKAGE
-CONCEALED: The electrical package shall consist of 1/2'' EMT concealed
in the panel and attached to flush mounted 2 x 4 boxes at receptacle
and switch locations; (7ea) wall switches: (39ea) duplex receptacles;
(39ea)quadruplex receptacles; (26ea) phone fixtures; (32ea) fluroescent
fixtures (100fc at desk height); 100 AMP, 120/240v breaker box (12
double/24 single) and breaker(s). This package must meet NEC (current
edition). All required connectors, fasteners, materials and
installation instructions for complete assembly shall be included.
NOTE: installation cost should be included as a separate line item.
Quotation should include costs for FOB destination to Hurlburt Field,
Fl. Warranty information, to include period and coverage, shall be
stated. Availability/projected delivery time after receipt of order
should be provided. FAR 52.212-1, Instructions to Offerors-Commercial,
applies. IAW FAR 52-212-2, Evaluation-Commercial Items, the Government
will award a contract resulting from this solicitation to the
responsible offeror whose offer conforming to the solicitation will be
most advantageous to the Government, price and other factors
considered. The Government anticipates the award of a firm-fixed price
purchase order. The following factors (in descending order on
importance) shall be used to evaluate offers: (i) technical capability
of the item offered to meet the Government requirement; (ii) past
performance, (iii) delivery time, (iv) price (including FOB destination
charges). Technical capability, past performance, and delivery time,
when combined, are 50% of the evaluation factor. Quotations should be
submitted in sufficient detail to be used in evaluation of the offers.
For evaluation of past performance, offerors are required to submit
information pertaining to previous sales to other government activities
or to private companies. Include contract number, date of purchase,
amount of purchase, and name/address/phone number of purchaser. Failure
to submit this information for evaluation will result in subpar scoring
in the applicable area of evaluation. Offerors should include a
completed copy of the provisions a FAR 52.212-3, Offeror
Representations and Certifications-Commercial Items, with its offer.
The FAR clauses at 52.212-4, Contract Terms and Conditions-Commercial
Items, 52.212-5, Contract Terms and Conditions Required to Implement
statues or Executive Orders-Commercial Items, 52-222-37, Employment
Reports on Special Disabled Veterans and Veterans of the Vietnam Era,
52-225-18, European Community are incorporated by reference. DFARS
252.225-7001, Buy American Act and Balance of Payment Program is
incorporated by reference. For a copy of the layout please call TSgt
Joni Norman at (904)884-3265. All questions should be directed to: TSgt
Joni Norman, (904)884-3265. Quotations should be submitted to 16
CONS/LGCS, Attention TSgt Joni Norman, PO Box 9190, Hurlburt Field, Fl
32544-9190 or faxed to (904)884-5372, Attention: TSgt Joni Norman, to
arrive not later than 2 August 1996. See Numbered Note(s): 1. (0204) Loren Data Corp. http://www.ld.com (SYN# 0370 19960723\54-0001.SOL)
54 - Prefabricated Structures and Scaffolding Index Page
|
|