COMMERCE BUSINESS DAILY ISSUE OF MAY 13,1996 PSA#159356 Contracting Squadron, 14100 W Eagle Street, Luke AFB AZ, 85309-
1217 67 -- SPECTRARADIOMETER SYSTEM AND NIGHT VISION IMAGING SYSTEM SOL
F02604-96Q1205 DUE 060896 POC Contact Ms. Florence Brooks, Buyer
(602)856-7179 ext. 234, or Msgt. John Castle, Contracting Officer (602)
856-7168. This is a request for quotation only, not a solicitation
package. Faxed quotes are preferred, fax to (602)856-3447, attn:
Florence Brooks, Buyer. Quantity of one (1). (Brand name only) PR-1980C
Pritchard Photometer Low Level SpectraRadiometer System (117VAC North
American Cord) Part No. 2900-0075-00. The Standard PR-1980C System
includes: PR-1980C Optical Head/Monochromator Assembly, OL-7 Lens,
Calibrated 10nm bandwidth slits, Spectrally calibrated ND-1 and ND-2
filters, PR-1980C Control Console, UCI-80-2+ Universal Computer
Interface, MOD 10 Software, User Self Calibration Software, IEEE-488
Interface Board(specify ISA or MCA bus), IEEE-488 cable, NIST traceable
Calibration (certified for six months), Instruction Manual. General
Performance Specifications: (Note ^ = degrees) Apertures: 2', 6', 20',
1^, 3^ and .4^x40^ rectangular aperture; Viewing Field: 1.9^, 5.9^ or
11^ (selectable) with OL-7 lens; Attenuators: 10X, 100X, 1000X and
10000X; Polarizers: Horizontal and vertical (PR-1980A mode only);
Detectors: S-20 photomultiplier (photometer) and silicon photo-diode
(spectroadiometer); Operating Temp.: 1^-35^C; Outputs: 3-1/2 digit
intensity panel meter, 4-1/2 digit wavelength display, BCD (25 pin) and
analog (0-10 volt). Photometer Specifications: Luminance Range: (full
scale) 1.999 x 10(to -4th) - 1.999 x 10(to 8th) footlamberts (10 {to
the -3rd} - 10 {to the 9th} cd*m {to the -2nd}; Luminance Accuracy: +
or - 2 to NIST Traceable Standard @ 2856K; Polarization: No measurable
error; Filters: Includes individually trimmed PHOTOPIC, relative RED
and BLUE; Stray Light: (optical Flare) (1% (as measured with OL-7
lens). Spectroradiometer Specifications: Standard Spectral Range:
380-830nm; full width half max bandwidth 10nm; Wavelenght
Repeatability: 0.5 nm (at constant temperature); Spectral Sensitivity;
380-600 nm 3.0X10(to the -13th)w*sr(to the -1st)*m (to the -2nd)
600-830nm 2.0X10(to the -14th) w*sr(to the -1st)*m (to the -2nd);
Absolute Accuracy: + or - 3% of reading from 700-830nm, + or - 5% of
reading below 400 or above 830nm, + or - 2% of full scale on any range
(whichever is greater); Wavelength Accuracy: + or - 1nm from 50^ to
100^F (10^to 37^C); Stray Light: less than 0.001% at 600nm; Colorietric
Accuracy: CIE 1931 x (+ or -) 0.001, y + or - 0.001 when measuring
illuminant A, + or - 0.005 for other sources. QUANTITY one (1) NVG -
Night Vision Imaging System (NVIS) Part number 2900-0064-04.
Spectroradiometry from 380-930 nm including NVIS calibration per
MIL-L-85762A, MOD 10 NVIS calculations (NVIS radiance and CIE 1976 u'v'
color boundaries), MS-7X Lens, MS-80A Lens (in place of OL-7 Lens)
WC-80 Wavelength Calibrator, 1nm bandwidth slits (uncalibrated) for
wavelength accuracy checks, SAVF-5 Spectral Accuracy Verification
Filter, FH-80 Filter Holder and SRS-3 Spectrally calibrated reflectance
standard. Arizona does not observe daylight savings time (0130) Loren Data Corp. http://www.ld.com (SYN# 0269 19960510\67-0001.SOL)
67 - Photographic Equipment Index Page
|
|