COMMERCE BUSINESS DAILY ISSUE OF APRIL 18,1996 PSA#1576Operational Contracting Division, 1940 Allbrook Dr, Ste 3 Bldg 1, WPAFB
OH 45433-5309 66 -- FULLY ASSEMBLED ELECTRON IMPACT IONIZATION TIME-OF-FLIGHT MASS
SPECTROMETER SOL F33601-96-Q-0642 DUE 042996 POC For Copy, ASC/PKWR,
Attn: Bldg 260, 1940 Allbrook Dr, Ste 3, WPAFB OH, 45344-5309, POC:
Jerl Traylor/PKWRS/513-257-6721 Fax No. 513-257-6390. This is a
combined synopsis/solicitation for commercial items prepared in
accordance with the format in Subpart 12.6, as supplemented with
additional information included in this notice. This announcement
constitutes the only solicitation; proposals are being requested and a
written solicitation will not be issued. This solicitation is issued
as a Request for Quotation (RFQ) and this includes all provisions and
clauses in effect thru FAC 90-37. This is a sole source requirement IAW
FAR 6.302-1. This RFQ has the following line items: 0001 1 EA Fully
assembled Electronic Impact Ionization Time-of-Flight (TOF) Mass
Spectrometer; 0002 1 EA Comstock Windows based IBM/PC compatible TOF
System Software Modules as described: 0001 - the system shall be fully
factor assembled and wired. It must be compatible with laser
ionization and mass resolution (m/delta m))300 for EII. The following
items shall include in the system: complete second order focusing
electronic impact ionization linear TOF mass spectrometer without
source chamber; TF-EI-402B electronic impact source region with
defining aperture in electron beam path; TF-SF-224A Source region
feedthroughs, wiring; TF-FT-101 One meter length floating flight tube
with integral metastable ion lens, and X-Y deflectors (The ion source,
flight tube, with ion optics, and detector must be mounted as a single
precision aligned assembly on a single 8 inch UHV flange; CP625C/50F 25
mm dual chevron micro channel plate detector with 50-ohm terminated
anode, mounted and wired to UHV feedthroughs; TF-VT-202A Flight tube
mounting and UHV vacuum tee, with removable conductance limit on source
end for differential pumping TOF from source chamber; set of electron
impact LTOF spectometer power supplies, to include: EGP-110 pulsed and
DC electron gun power supply, externally triggerable; EGP-112R pulsed
repeller power supply, computer interfaceable; TFP-210 Flight tube,
deflectors, ion lens, and detector power supply system, computer
interfaceable; all required cables. 0002 - Includes power supply and
data acquisition system control, import of data from data acquisition
system to the PC, display of mass spectra on computer monitor, and mass
calibration, these modules must be designed for use with national
instruments lab view as a software platform. Delivery required no later
than 29 Jun 96, FOB destination, delivery to WL/MLBT. The following
clauses and provisions apply; 52.212-1, 52.212-3 shall be included with
any offer, 52.212-4, and 52.212-5. Offers must be received no later
than 4:00 pm, 29 Apr 96. See Numbered Note(s): 22. (0107) Loren Data Corp. http://www.ld.com (SYN# 0273 19960417\66-0001.SOL)