COMMERCE BUSINESS DAILY ISSUE OF JANUARY 31,1996 PSA#1521Commander, Pacific Division, Naval Facilities Engineering Command,
Contracts Department, Building 258, Pearl Harbor, HI 96860-7300 (Code
0211) C -- ARCHITECT-ENGINEER SERVICES FOR FY99 BRACON IV PROJECT P-411U,
METEOROLOGICAL BUILDING ADDITION, NAVPACMETOCCEN PEARL HARBOR, HAWAII
SOL N62742-96-R-0005 POC Contact Ms. Judy Wong, Contract Specialist,
(808) 474-1402 Services include, but are not limited to, design and
engineering services for the preparation of final plans,
specifications, and cost estimates to provide for the construction of
a reinforced concrete building addition to the existing Naval Pacific
Meteorological and Oceanography Center (NAVPACMETOCCEN) facility,
Building 398, Makalapa to accommodate the relocation of the Joint
Typhoon Warning Center (JTWC). Scope includes construction of
administration/office spaces and Sensitive Compartmented Information
Facility (SCIF). The addition will be a single story structure with
reinforced concrete foundations, slabs, beams, walls and roof. This
project provides air conditioning; ventilation system; fire protection
and alarm systems; electrical power, lighting, and telephone systems;
handicap accessibility; grounding systems; asphalt-compacted pavement;
building shielding; lighting protection systems; site work; supporting
utilities; and relocating drainage lines. If asbestos or hazardous
materials exist, the Architect-Engineer (A-E) contractor shall identify
them and provide for their disposal in the construction plans and
specifications in accordance with applicable rules and regulations
pertaining to such hazardous materials. The selected A-E may be
required to participate in a pre-fee meeting within seven days of
notification and provide a fee proposal within ten days of the meeting.
Initial design and engineering services include preparation of project
engineering documents. Follow-on phases may include the preparation of
preliminary design documents; preparation of final design;
post-construction award services; construction surveillance and
inspection services; and operational and maintenance support
information services. Estimated construction cost is $1,000,000 to
$10,000,000. Estimated start and completion dates are April 1996 and
March 2002, respectively, including review periods. Proposals may be
subject to an advisory audit performed by the Defense Contract Audit
Agency. The following selection evaluation criteria, in relative order
of importance, will be used in the evaluation of A-E firms: (1)
Professional qualifications of firm and staff proposed in the design of
electronic equipment, communication and/or Sensitive Compartmented
Information Facility (SCIF) in the Pacific basin region and/or Tropical
Environment. (2) Specialized recent experience and technical competence
of firm or particular staff members in the design of electronic
equipment, communication and/or Sensitive Compartmented Information
Facility (SCIF) in the Pacific basin region and/or Tropical
Environment. (3) Past performance on contracts with Government agencies
and private industry in terms of cost control, quality of work, and
compliance with performance schedules. (4) Capacity to accomplish the
work in the required time. (5) A-E firm's design quality control
practices/techniques. (6) Demonstrated success in prescribing the use
of recovered materials and achieving waste reduction and energy
efficiency in facility design. (7) Location in the general geographical
area of the project and knowledge of the locality of the project;
provided that application of this criterion leaves an appropriate
number of qualified firms, given the nature and size of the project.
(8) The volume of work previously awarded to the firm by the Department
of Defense shall also be considered, with the object of effecting an
equitable distribution of Department of Defense A-E contracts among
qualified A-E firms and firms that have not had Department of Defense
contracts. (9) Use of Small or Small Disadvantaged or Women-owned Small
Business firms shall also be considered. Subcontracting Plan is
required from large business firms with proposed fee of over
$500,000.00. This prospective contract is a potential 100 percent
set-aside for small business (SB) concerns. The small business size
standard classification is SIC 8712 ($2.5 million in annual receipts).
If adequate interest is not received from highly qualified SB
concerns, this solicitation will automatically be opened to all firms
regardless of size or concern without further notice. Replies to this
notice are, therefore, requested from all concerns as well as SB
concerns. Each firm's past performance and performance rating(s) will
be reviewed during the evaluation process and can affect the selection
outcome. A-E firms which meet the requirements described in this
announcement are invited to submit complete, updated Standard Forms
254, Architect Engineer and Related Services Questionnaire, and 255,
Architect-Engineer and Related Services Questionnaire for Specific
Project, to the office shown above. A-E firms utilized by the prime A-E
must also submit completed Standard Forms 254 and 255. Only one copy of
each form is required. IN BLOCK 10 AND AN ADDENDUM THERETO, IF
NECESSARY, STATE WHY YOUR FIRM IS SPECIALLY QUALIFIED BASED ON EACH OF
THE ABOVE SELECTION EVALUATION CRITERIA. FOR SELECTION EVALUATION
CRITERION ''(2)'', PROVIDE THE FOLLOWING INFORMATION FOR ONLY THE STAFF
PROPOSED FOR THIS WORK USING THESE COLUMN HEADINGS: ''NAME'', ''RELATED
PROJECTS WORKED ON'', ''YEAR'', ''FIRM'', AND ''TECHNICAL ROLE''. Show
the office location where work will be done and describe the
experience and location of those that will do the work. Firms
responding to this announcement within 30 days from publication date
will be considered. Firms must submit forms to the Contracts Department
by 2:00 p.m. HST, on the closing date. Should the due date fall on a
weekend or holiday, Standard Forms 254 and 255 will be due the first
workday thereafter. This is not a request for a proposal. See Note 24.
(0029) Loren Data Corp. http://www.ld.com (SYN# 0017 19960130\C-0010.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|