|
COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 15,1995 PSA#1473DAHLGREN DIVISION, NAVAL SURFACE WARFARE Center, 17320 DAHLGREN Road,
DAHLGREN, VIRGINIA 22448-5100 59 -- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS SOL
N00178-96-Q-2000 DUE 120195 POC Rick Ballenger, Code S129, (540)
653-7942. The Naval Surface Warfare Center, Dahlgren Division is
seeking potential sources to deliver, install, integrate, and test new
or refurbished shipboard interior communications components
(navigation) equipment as follows: (1) WIND SPEED/DIRECTION SYSTEM
(Speed and Direction Transmitter, Type ''F'', with rack mount adapters
to fit 24'' equipment rack, includes connectors, cable assemblies, and
technical manual; Wind Speed and Direction Digital Interface. Unit to
mate with wind speed and direction equipments, with technical manual;
Wind Speed/Direction Detector, Type ''F'', with all exterior mounting
brackets and hardware, including all connectors and cable assemblies,
and technical manual), (2) SHIP's EM LOG SYSTEM (EM Log Transmitter, MK
4 MOD 1 with rack mount adapters to fit 24'' equipment rack, including
connectors and cable assemblies, and technical manual; Manual Dummy
Log Unit (Part of EM Log) with mating connectors and cable assemblies;
Distance Indicator (Part of EM Log), (3) SYNCHRO AMPLIFIER (MK 31
Synchro Amplifier (1X, 36X) with rack mount adaters to fit 24'' rack,
technical manual), (4) synchro amplifier (MK 41 Synchro Amplifier (2X,
36X) with rack mount adapters to fit 24'' rack, and technical manual),
(5) SYNCHRO AMPLIFIER (MK 27 Synchro Amplifier (DG) with rack mount
adapters to fit 24'' rack, and technical manual), (6) EQUIPMENT RACK
(heavy duty 24'' equipment rack enclosure, internally wired for power
and signal distribution, connectorized with input/output connectors or
rear, and (7) FIDDLEBOARD ASSEMBLY (including hardware, cables and
connectors). Delivery, installation, integration and system testing of
the required components shall be performed at the AEGIS Combat System
Center, Wallops Island, VA. Interested sources are invited to
demonstrate their capabilities by providing the following information:
(1) firm name, point of contact, and business size status, (2)
description of ability to fulfill the requirement, including
integration and testing (3) demonstration of past experience, including
applicable contract numbers, quantity of units, contracting agency with
current point of contact and phone number, and brie contract summary.
Responses should reference Sources Sought No. N00178-96-Q-2000 and must
be received by 1 December 1995. Submit responses to Contracting Officer
(Attn: R. Ballenger, Code S129). Submissions may be e-mailed to
slongbr@relay.nswc.navy.mil, or telefaxed on (540) 653-4089. NOTE: The
Government will not pay for any information provided in response to
this sources sought notice. No solicitation package currently exists.
(0317) Loren Data Corp. http://www.ld.com (SYN# 0240 19951114\59-0019.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|