COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 11,1995 PSA#1449Sa-Alc Test Systems Branch, 308 Avionics Circle Suite # 2, Kelly Afb,
Texas 78241-5947 66 -- ADAPTER KIT, TEST SOL F41608-95-R-32139 DUE 112495 POC For copy,
Fax request to Buyer at (210)925-1054, For additional information
contact James, M./ldkaa/210-925-7661 Item 0001 NSN 6625-01-395-9241DQ
P/N: X7008F, SIZE/DIMENSIONS: Case Size Predominant Material of
Manufacture: Electronics Form/Fit/Function: The XBAND verification kit
(test set) will be used in the MDA developed calibration procedure to
verify that the HP 8719C network analyzer systems is working within
its specifications and that it has performed a valid measurement
calibration in the XBAND connector type. The item consists of the
following: 1EA-Attenuator 20DB, 1EA-Attenuator50DB 1EA-Precision
Straight Set ZO, 1EA-Precision Mismatch Section, 1EA-Disk with Data
(Uncertainty Limits of an HP87C System), 1EA-Operating Instructions,
1EA-Instrument Case. 6ea. Applicable to: F15 Acft Radar. Destn: Kelly
Afb, Texas 78241-5947. Delivery: 31 JUL 96 3 ea 31 DEC 96 3 ea Item
0002 NSN 6625-01-395-3515DQ Adapter Kit, Test P/N: 8651C,
Size/Dimensions: Case Size Predominant Material of Manufacture:
Electronics Form/Fit/Function: This item provides a means to calibrate
off-station the F15 AIS network analyzer drawer (p/n 6457375-1). The
drawer is part of the F15 ACFT Radar test station (p/n 13A6521-2, SERD
ITEM 0071, AN/GSM-345). The item consists of the following:
1EA-Attenuator 20DB, 1EA-Attenuator 50DB, 1EA-50 OHM Airline, 1EA-25
OHM Mismatch Airline, 1EA-Disk with data (uncertainty limits of HP
8719C SYS), 1EA-Operating instructions, 1EA-Instrument Case. 6ea.
Applicable to: F15 Acft Radar. Destn: Kelly Afb, Texas 78241-5947.
Delivery: 31 JUL 96 3 ea 31 DEC 96 3 ea Item 0003 NSN
6625-01-395-9200DQ Adapter Kit, Test P/N: 8051C, Size/Dimensions: Case
Size Predominant Material of Manufacture: Electronics
Form/Fit/Function: The 3.5MM verification kit will be used in the MDA
developed calibration procedure to verify that the HP8719C network
analyzer system is working within its specifications and has performed
valid measurement calibration in the 3.5MM (SMA) connector type. SERD
5298. This item consists of the following: 1EA-Attenuator 20DB,
1EA-Attenuator 50DB, 1EA-7.5CM 50 OHM Airline, 1EA-Disk with
Data(uncertainty limits of on HP 8719C SYS), 1EA-Operating
instructions, 1EA-Instrument Case. 6ea. Applicable to: F15 AisArts.
Destn: Kelly Afb, Texas 78241-5947. Delivery: 31 JUL 96 3 ea 31 DEC 96
3 ea Government furnished data not available. The approximate
issue/response date will be 25 Oct 95. To: Maury Microwave Corp,
Ontario Ca 91764-0000. No telephone requests. Only written or faxed
requests received directly from the requestor are acceptable. All
responsible sources may submit a bid, proposal, or quotation which
shall be considered. Authority: 10 U.S.C. 2304(C)(1), Justification:
Supplies (or Services) required are available from only one or a
limited number of responsible source(s) and no other type of supplies
or services will satisfy agency requirements. Buyer's name (point of
contact listed above) should be included on all solicitation requests.
In addition, please include a FSCM/cage code for mailing purposes. See
Note (s) 22. (0279) Loren Data Corp. http://www.ld.com (SYN# 0278 19951010\66-0001.SOL)