COMMERCE BUSINESS DAILY ISSUE OF AUGUST 9,1995 PSA#1406National Institutes of Health, National Institute of Diabetes and
Digestive and Kidney Diseases (NIDDK) The Natcher Building, Room 6AN24D
45 Center Drive MSC 6600 Bethesda, MD 20892-6600 66 -- NITROGEN GAS CRYOSTREAM COOLER INCLUDES: CRYOSTREAM COLDHEAD,
PROGRAMMABLE TEMPERATURE CONTROLLER, GAS PUMP TUBSET AND COOLHEAD
CABLE, REACTION HEATER AND PUMPING ADAPTER. SOL NIH-NIDDK-95-113 DUE
082895 POC Desiree Kelly, Purchasing Agent 301-594-8831. The National
Institutes of Health (NIH) National Institute of Diabetes and Digestive
and Kidney Diseases (NIDDK) intends to purchase through a Request for
Quotation (RFQ) Nitrogen Gas Cryostream Cooler. The Oxford Cryostream
cooler is used for low temperature data collection in X-ray diffraction
experiments with protein crystals. The cryostream cooler must be able
to supply dry nitrogen gas stream of programmable temperature range 80
to 375 K. The temperature controlling unit must be programmable and
capable of controlling to + 0.1 K. The temperature controlling unit
must be able to faciltate for temperature ramps, planteaus and combined
ramps/plateaus so that automatic data collections at different
temperatures can be accomplished. The temperature controlling unit must
have a built in RS232 interface to allow it to be interrogated or
programmed remotely. The liquid N2 usage must be approximately 0.6
1/hour or less. The cooler head must be small ((10cm diameter, (50cm
long), portable, and supplied with a support stand equipped with a
translation stage with adjustable angle. The cryo-transfer tubing
conencting the cooler head and liqud N2 storage vessel must be flexible
and 130 cm or longer. The cryo-transfer must be compatible with the
existing X-ray generator,monochrometer, mirror box and detector unit,
and their geometrical arrangement within a tightly confined space. The
Institute intends to purchase this equipment by Other Full and Open
Competition from the Oxford Cryosystems. The intended source Oxford
Cryosystems is the manufacture of the Nitrogen Gas Cryostream cooler,
and guarentees complete integratio of the cryostream cooler which must
be compatible with the exisiting x-ray generator, monchrometer, mirror
box and detector unit, and their genometical arrangement within a
tightly confined space. All responsible sources may submit a Request
For Quotation, which if timely received, shall be considered by the
agency. (See Note 22). It is anticipated that Request For Quotation
(RFQ) Number NIDDK-SSAS-95-113, will be available fifteen (15) days
after the publication date of this synopsis. Receipt of quotations will
be due ten (10) days after the release of the RFQ. The anticipated
award date is August 28, 1995. Requests for copies of the RFQ must be
in writing and may be requested by FAX (301)-480-4226. Quotations must
be submitted in writing to the National Institutes of Diabetes and
Digestive and Kidney Diseases (NIDDK) The Natcher Building, Room 6AN32
45 Center Drive MSC 6600 Bethesda, Maryland 20892-6600 Attention:
Desiree Kelly FAX quotations will only be accepted if dated and signed
by an authorized company representative. (0219) Loren Data Corp. http://www.ld.com (SYN# 0426 19950808\66-0001.SOL)