Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JULY 25,1995 PSA#1395

Defense Information Systems Agency, Code D4131, 701 S. Court House Road, Arlington, VA 22204-2199

60 -- FIBER OPTIC CABLING SOL DCA100-95-R-0101 DUE 091195 POC Contact Mr. Andrias Woody, 703, 607-4607, Contract Specialist, Facsimile 703, 607-4611, Mr. Boyd E. Blevins, 703, 607-4601, Contracting Officer The contractor shall design and install extensions to the fiber optic based distribution system to support audio-visual requirement. Indoor and outdoor fiber optic cabling shall be installed utilizing single mode, 8.5/125 micron, 1300 and 1550 nano-meter fiber optic cabling. Each cable shall have 24 strands of fiber although not all strands will be terminated at each locations. Indoor fiber optic cabling shall be riser rated cable and shall conform to Flame Resistance in accordance with UL 1666. Siecor MIC cable or equivalent shall be used. Existing Government conduits shall be used to the greatest extent possible. Outdoor fiber optic cabling shall be rated for direct underground bury and shall have an armored sheathing inbedded into jacket. Siecor Double Jacket, Single Armor Cabling or equivalent shall be used. Outdoor installation shall utilize an outdoor pedestal of the type, design and color previosuly installed. There shall be hardware with the pedestal for termination of 24 fibers on ST connectors. Additional locations shall have fiber optic connectivity installed and interconnected with the Fiber Distribution System. A table will be made available to identify specific locations, the type of termination device to be used and the number of fibers to be terminated. Each run of fiber optic cabling will terminated at one of the Main or Intermediate Distribution Frames (MDF or IDF). Individual room user connection points shall be installed in manner to protect the fiber optic connectors, provide for ease of access to the connectors and provide for the historical preservation of the rooms installed. The contractor shall use modular design wiring/utility closet hardware to ensure ease of maintenance support after installation is completed. Rooms can be categorized as having little or no closet space and moderate closet space. In rooms where there is little or no closet space and high cisibility shall use an on-wallbox with a double gang wall bezel capable of terminating 12 fibers on ST connectors. Rooms that have little or no closet space and a level of visibility shall use a surface mount wall box capable of terminating 12 fibers on ST connectors. Rooms that have adequate closet space shall use a fiber wall panel capable of terminating 24 fibers on ST connectors. MOD-TAP High Performance System 100 components or equivalent shall be used. All interested parties must submit a written request for a copy of the solicitation within 15 calendar days of this notification. The request should be written on company letter-head, the title of the requirement, to include the solicitation number and contracting officer's name, address/code and point of contact. (0202)

Loren Data Corp. http://www.ld.com (SYN# 0565 19950724\60-0001.SOL)


60 - Fiber Optics Materials, Components, Assemblies and Accessories Index Page