Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JULY 13,1995 PSA#1387

JACKSONVILLE DISTRICT OFFICE, U.S. ARMY CORPS OF ENGINEERS, P.O. BOX 4970, JACKSONVILLE, FL 32232-0019

H -- REMOVE FUEL STORAGE TANKS AND UNDERGROUND PIPING AND REMOVE AND INSTALL ONE WASTE OIL TANK, NAVAL AIR STATION, JACKSONVILLE, FLORIDA SOL DACA17-95-B-0046 DUE 091995 POC Contract Specialist, Robert Mosteller, (904)232-3739 The project consists of furnishing all material, labor, tools, equipment, utilities, water and fuel supply, vehicular transportation, manifests, certificates, licenses, permits, soil borings and all necessary incidental services required to meet all Federal, State, and local requirements to remove, dismantle, temporarily store, purge, clean, haul, and dispose of four underground storage tanks, six control tanks, one waste oil tank and approximately 5,600 linear feet of piping, tank and piping contents, and ancillary equipment which includes concrete and steel structures, pavements and miscellaneous items associated with tanks. The project involves four underground storage tanks (27,202 gal. each), six control tanks (1000 gal. each), and one 500 gal. waste oil tank. The project involves installation of a new waste oil tank and double wall containment piping, anchor slag, tank appurtenances and leak detection and inventory monitoring system. The project also includes the restoration of all sites to original lines and grades. Additional remediation, on a limited basis at the site may also be required if soil and/or groundwater contamination is detected by the removal of the tanks and tank appurtenances. The Contractor shall be an authorized Florida Pollutant Storage System Specialty contractor (PSSSC) licensed by the Florida Department of Professional Regulation (FDPR). All subcontractors or individuals performing soil and ground water sampling must have an approved generic assurance plan on file with the Florida Department of Environmental Protection (FDEP). In addition, only laboratories that have a generic quality assurance plan approved by FDEP my be used to analyze soil and groundwater samples. LICENSING AND CERTIFICATION PROOF REQUIRED WITHIN 5 DAYS AFTER BID OPENING. Contractor's analytical laboratory must be validated by the Corps of Engineers' Missouri River Division. Proof of validation must be furnished prior to issuance of Notice to Proceed. See paragraph ''Laboratory Validation and Certification Requirements'' of SECTION 20820: REMOVAL AND DISPOSAL OF UNDERGROUND STORAGE TANKS AND PIPING. All persons entering the work site must have current OSHA Hazardous Material Health and Safety annual training as per 29 CFR Part 1910.120. The contract shall require personnel specialized in removal, disposal and installation of underground storage tanks as well as minor construction workers. The contractor must obtain security clearance from the Jacksonville Naval Air Station and abide by Station regulations as put forth in SECTION 01010, Paragraph 6, CONTRACTOR ACCESS AND USE OF PREMISES. Magnitude of construction is between $250,000 to $500,000. Pre-Solicitation Notice will be issued on or about 07 Jul 95. Invitation DACA17-95-B-0046 will be issued on or about 04 Aug 95 and opened on or about 19 Sept 95. Cost of Plans and Specifications is $40.00. (Non-Refundable) Checks should be made payable to F & A Mobile District, and sent to U.S. Army Corps of Engineers, Jacksonville, Florida. Request for plan holders list should be in writing or FAXED to our office (904) 232-2748, ATTN: Kenneth Faulk. THIS ACQUISITION IS SET-ASIDE FOR SMALL DISADVANTAGED BUSINESSES. SIC Code 1629. No Collect Calls. (0192)

Loren Data Corp. http://www.ld.com (SYN# 0045 19950712\H-0001.SOL)


H - Quality Control, Testing and Inspection Services Index Page