Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 13,1995 PSA#1366

Contracts Competency, Naval Air Warfare Center Aircraft Division, Bldg 88, Mail Stop 32, 47211 Whalen Road, Patuxent River, MD 20670-5304

95 -- PLATING AND RINSE TANKS SOL N00421-95-B-5243 POC Lisa Abell, Contract Specialist, (301) 826-1830 x 111 LINDA SUGGS, Contracting Officer, (301) 826-1828 x108. The Naval Air Warfare Center Aircraft Division, Patuxent River, Maryland, has a requirement for a total of twenty-one (21) Plating and Rinse Tanks for the new Plating Shop being developed in Building 2186 of the Naval Air Station. All tanks shall be fabricated from either .75'' thick PVC, polyethylene, or polypropylene. There shall be a .75'' x 2.75'' rim on all tanks. Ten (10) of the twenty-one (21) required tanks shall be rinse tanks and shall include a dam type overflow 48'' or 52'' long with a 3'' welded half coupling outlet. Eleven of the twenty-one (21) required tanks shall be chemical process tanks which must contain an outer 1/2'' thick plastic tank that will serve as secondary containment. Additionally, all chemical process tanks shall have a plastic base to raise the tank rim to 36''. Two (2) of the eleven (11) chemical process tanks shall be hot tanks. Each hot tank will require one steel girth encapsulated in plastic. Individual tank numbers shall be stencilled with 4'' high black letters and appropriate numbers. All twenty-one (21) tanks shall have outside dimensions of 52'' long x 38'' wide x 36'' deep. Inside tank dimension requirements vary. Ten (10) of the twenty-one (21) tanks shall have inside dimensions of 48'' long x 34'' wide x 34'' deep. Eleven (11) of the twenty-one (21) tanks shall have inside dimensions of 52'' long x 34'' wide x 34'' deep. Of the eleven (11) chemical process tanks, two (2) are hot tanks. The other nine (9) chemical process tanks shall be used for one each of the following process descriptions: (1) Nitric Acid tank, (2) Hydrochloric Acid tank, (3) Cadimum tank, (4) 5-3 Chromate tank, (5) Aluminum cleaner tank, (6) Desmutter tank, (7) Irridite 14-2 tank, (8) Chromic Acid tank, and (9) Sulfuric Acid Anodize. Interested parties may request copies of the Invitation For Bid (IFB) by mail to the address stated above, or by fax request. All requests must be submitted in writing. This requirement is 100% set-aside for small business concerns. Comments or questions may be addressed to Lisa Abell by phone at (301) 826-1830 x111, fax (301) 826-1864, or mail to the address above. See Numbered Note(s): 1. (0160)

Loren Data Corp. http://www.ld.com (SYN# 0466 19950612\95-0001.SOL)


95 - Metal Bars, Sheets and Shapes Index Page