COMMERCE BUSINESS DAILY ISSUE OF JUNE 5,1995 PSA#1360Warner Robins ALC, Office of Small and Disadvantaged Business
Utilization (WR-ALC/BC), Source Development Section, Attn: Tom
Robertson (95A11), 180 Page Rd., Robins AFB GA 31098-1600 12 -- DEVELOP, FABRICATE, AND PRODUCE A REPLACEMENT CATHODE RAY TUBE
MONITOR, ASQ-151, ASQ-175, AND ASQ-184, B-52 AIRCRAFT Contact Tom
Robertson (95A11), Source Development Analyst, Robins AFB, GA
31098-1600, 912-926-6726. This is NOT a presolicitation notice pursuant
to FAR Part 5, but is a MARKET SURVEY to identify potential sources for
the development, fabrication, and production of a replacement Cathode
Ray Tube (CRT) Monitor Applicable to the B-52 Aircraft. The replacement
display, pseudo NSN 1280-BC-111-2222, shall be capable of presenting
FLIR video, TV video, radar data, and assorted symbology and numerics.
The display shall be a form fit and function replacement conforming to
all electrical, mechanical, and operator interfaces on the Aircraft.
Satisfactory performance is required in both the cockpit and downstairs
crewstations. Nuclear hardening requirements for the CRT Monitor exist.
Requirements for delivery may include but are not limited to: 1) Two
each First Articles 2) Level III Data 3) Full system specifications 4)
Techncal Orders 5) Assorted spares 6) Priced production options.
Period of performance is expected to be (12) twelve months to include
full qualification testing, reliability and maintainability (R&M)
tests, and flight tests. It is estimated that the program will begin in
the first quarter of calendar year 1996. A formal solicitation does not
exist at this time. This survey is for information and planning
purposes only and does not constitute an Invitation for Bid or Request
for Proposal and is not to be construed as a commitment by the
Government. WR-ALC anticipates a competitive acquisition using
government furnished specification, statement of work, etc. Potential
sources interested in participating in this survey must provide a
written response that includes: Company Name, Address, CAGE Code, Point
of Contact, Size of Business pursuant to SIC 3812, Statement of
Domestic or Foreign Ownership, a copy of your DD Form 2345 - Military
Critical Technical Data Agreement, and documentation showing
capabilities and experience (brochures, literature, contractual
histories, etc.). Contractors may obtain a DD Form 2345 certification
by contacting Defense Logistics Service Center, at 1-800-352-3572. The
extent of foreign participation has not yet been determined and
release of information will be determined at the time of solicitation.
Capability and experience documentation must include discussion of
your company's experience in the following areas: 1) Your Company's
experience in the design and construction of Cathode Ray Tube Monitors.
2) Your company's experience and understanding of signal processing and
aircraft interfaces needed to display FLIR video, TV video, radar data,
and assorted symbology and numerics. 3) Proven capability to
manufacture Cathode Ray Tube Monitors to military specifications
(include contract numbers, brief description of contract contents,
dates of performance, military organization, name and phone number of
contracting officer, etc.) 4) Your company's experience in design and
construction of nuclear hardened Cathode Ray Tube Monitors (include
contract numbers, brief description of contract contents, dates of
performance, military/civilian organization, name and phone number of
contracting officer, etc.). Failure to provide all requested
information may result in your company not being placed on the initial
source list when/ if a requirement generates. Large and small
businesses are encouraged to participate. Questions or responses to
this Market Survey should be addressed to: Tom Robertson (95A11), 180
Page Rd., Robins AFB GA 31098-1600, Phone: 912-926-6726. All responses
must be received no later than twenty (20) days from the date of this
publication. The approximate issue response date will be 18 May 95.
(151) Loren Data Corp. http://www.ld.com (SYN# 0267 19950602\12-0007.SOL)
12 - Fire Control Equipment Index Page
|
|