COMMERCE BUSINESS DAILY ISSUE OF MAY 19,1995 PSA#1350Operational Contracting, 205 W.D Ave., Suite 541, Eglin AFB FL
32542-6862 66 -- DUAL-BEAM SPECTROPHOTOMETER SOL F08651-95-R-0101 DUE 060795 POC
Contact B. Hochmuth, (904) 882-5169, Contract Specialist, Contracting
Officer, Bonnie Fitch. The Advanced Guidance Division of Wright
Laboratory is seeking firms that have the capability to produce and
deliver off-the-shelf a dual-beam spectrophotometer to be used to
characterize materials used in the continued development of laser radar
systems. The dual-beam spectrophotometer shall be capable of conducting
absorption and transmission studies in a minimum wavelength range from
200 nanometers to 3000 nanometers. The spectral bandwidth in the
ultraviolet and visible region shall be adjustable over a minimum range
of 0.05 nanometers to 5.00 nanometers with increments between bandwidth
settings equal to or better than 0.02 nanometers. The spectral
bandwidth in the near infrared region shall be adjustable over a
minimum range of 0.02 nanometers to 20.0 nanometers. The stray light
measured at 220 nanometers and at 370 nanometers shall be equal to or
better than 0.0001 percent transmission. The wavelength accuracy in the
ultraviolet and visible region shall be equal to or better than 0.15
nanometers. The wavelength accuracy in the infrared region shall be
equal to or better than 0.05 nanometers. Wavelength reproducibility in
the infrared region shall be equal to or better than 0.08 nanometers.
The photometric accuracy measured at 1A shall be equal or better to
than 0.004A. The photometric accuracy measured at 0.5A shall be equal
to or better than 0.002A. The data collection and analysis functions of
the spectrophotometer shall be controlled separately by computer.
Software shall allow collected data to be converted to a text format
that can be interpreted by a PC-based text editor. Spectrophotometer
control software shall allow the user to set scan wavelength limits, a
constant scan speed, wavelength step size and slit width. The
spectrophotometer shall be capable of scanning in a constant
photometric value mode and in a constant slit width mode. The
spectrophotometer must be upgradable to perform reflectance
spectroscopy. Technical questions may be directed to Kent Broome at
(904) 882-9443, ext 1259 or Ken Dinndorf, (904) 882-1726. Replies to
this synopsis should be provided to AFDTC/PKOS, 205 W. D Avenue, Suite
541, Eglin AFB FL 32542-6862. All responsible sources may submit an
offer which will be considered. (No contract award will be made on the
basis of bids/proposals received in response to this synopsis.) Firms
responding to this solicitation should reference F08651-95-B-0101 and
indicate whether they are or are not a small or small disadvantaged
business concern as defined in FAR 52.219-1 and 52.219-2 and whether
they are a manufacturer or dealer/distributor. The Air Force reserves
the right to consider a small business set-aside based on responses
hereto. Requests for copies of this solicitation must be in writing or
fax (904) 882-9442. Telephone requests will not be honored. (0137) Loren Data Corp. http://www.ld.com (SYN# 0368 19950518\66-0002.SOL)