|
COMMERCE BUSINESS DAILY ISSUE OF APRIL 28,1995 PSA#1335National Institutes of Health, Division of Procurement, AB-D, 6120
Executive Blvd., Eighth Floor, Rockville, MD 20892 Room 816 70 -- PROPRIETARY -OFF-THE-SHELF-SOFTWARE SOL, POC Dianne Kelly,
Contract Specialist, 301-402-3078. The National Institutes of Health
(NIH) in Bethesda, Maryland, under Statutory Authority: 41 USC 253
(c)(1) (FAR 6.302-1) - (''Only one responsible source and no other
supplies or services will satisfy agency requirements''). This Notice
of Intent, announcing that the National Institutes of Health (NIH) in
Bethesda, MD intends to provide a one year contract with Applied
Biosystems, Division of Perkin-Elmer Corporation, 850 Lincoln Center
Drive, Foster City, CA 94404. Any response must reference
QPM40338/QPM50114. The requirement consists of the following: Item #1:
Cat# 672A-90, Qty. 4, Desc. Genescan 672 Software Kit. Item #2: Cat#
401614, Qty. 3, Desc. Genotyper Software. THE FOLLOWING ADDITIONAL
INFORMATION IS FURNISHED FOR THE REQUIRED ITEMS: 1) The Genescan (TM)
672 Software Kit shall be compatible and work with the Applied
Biosystems 373A DNA Sequencer to size and quantify amounts of
fluorescently labeled DNA fragments. The average precision of sizing
DNA fragments in the 50-350 base pair range, when using Applied
Biosystems protocols, shall be greater than 99 per cent. The DNA
Sequencer and GENESCAN (TM) shall detect as little as 100, 100, 400,
and 800 attomoles of FAM (blue), JOE (green), TAMRA (yellow), and ROX
(red) fluorescent dyes, respectively. Overlapping DNA fragment bands
with different-color labels shall be easily distinguished and
accurately quantitated. The linear dynamic range of detection shall be
over three (3) orders of magnitude. Shall allow up to 36 samples to be
loaded per gel. Shall allow extensive multiplexing of samples, using
multiple dye labels, shall have the ability to analyze up to 24
microsatellite markers in a single gel lane. The data shall be viewable
in the following three (3) formats: Gel View, Electropherogram and
Tubular Data. 2) The Genotyper (TM) Software shall be compatible and
work with the Applied Biosystems 373A DNA Sequencer and the Genescan
(TM) 672 Software Kit, for automated genetic analysis applications.
Shall have the following key features: User-definable macros for method
automation, Manual and automatic allele scoring, Within lane and
lane-to-lane data normalization, Simple data transformations and peak
filtering, Within lane and lane-to-lane peak statistics, Mendelian
Inheritance Checker, Audit trail for user-edited data, Searching,
sorting, and selection of data subsets, and, User- definable data
formats. Shall include Genotyper application software, application
macros (one for genotyping specific microsatellite markers and one for
a quantitative application), user and reference manuals, an
application tutorial manual with sample data files, ninety-day warranty
on parts, and, a single- user license. ABI is the only supplier of
software capable of interfacing with the ABI 373 or 377 to perform
genotyping. We have purchased the hardware, which requires this
software to function. Hardware and software purchase requests were made
concurrently and submitted with justifications. Telephone requests will
not be honored. Affirmative responses are defined as written responses
entitled ''Capability Statement'', with all data enclosed that are
required to demonstrate their ability to satisfy this requirement.
Terms and conditions, destination information, description information,
descriptive literature/technical information describing the items
proposed. Concerns offering to furnish equivalent/equal work to the
items listed above will be considered only if responding with clear and
convincing documentation demonstrating their ability to meet the
requirements of this synopsis. Written responses shall include complete
pricing information, and a complete description of the
hardware/software to be provided, containing sufficient technical
information to permit agency analysis to establish a bonafide
capability to meet the stated requirements as listed above. Responses
will be evaluated according to who can meet the requirements at most
favorable terms to the Government, considering the lowest overall cost
alternative not necessarily at the lowest price. Only affirmative
responses will receive full consideration. If no affirmative responses
are received within (45) days from the date of listing this synopsis
in the CBD which demonstrate a lower overall cost alternative available
to the Government, the Contracting Officer will proceed with this
acquisition to Applied Biosystems. All responsible sources may respond
to this notice which shall be considered by this Agency. This is not
a formal solicitation. Adequate detailed data by which to evaluate
capability should be sent to Attn.: Ms. Dianne Kelly, at the point of
contact listed above. All responses from responsible sources will be
fully considered. As a result of analyzing responses to this synopsis
of intent, the contracting officer may determine that a solicitation
will be issued. If a solicitation is issued, no additional synopsis
will be published. Any such solicitation will be issued to all firms
that respond to this synopsis of intent or otherwise request a copy of
the solicitation. If no written responses are received that
demonstrate a lower overall cost alternative to the Government is
available, a contract will be placed to Applied Biosystems. SEE NOTE
22. (0116) Loren Data Corp. http://www.ld.com (SYN# 0390 19950427\70-0001.SOL)
70 - General Purpose ADP Equipment Software, Supplies and Support Eq. Index Page
|
|