COMMERCE BUSINESS DAILY ISSUE OF MARCH 30,1995 PSA#1314Resident Officer in Charge of Construction, Building 504, Naval Air
Warfare Center, Patuxent River, Maryland 20670-5040 Y -- EXTENSION TO THE FIBER OPTIC DISTRIBUTION NETWORK, NAVAL AIR
WARFARE CENTER AIRCRAFT DIVISION, NAVAL AIR STATION, PATUXENT RIVER,
MARYLAND 20670-5040 Sol N62477-94-B-3063. POC Procurement Technician,
Karl Hanson, 301-826-3854, Contracting Officer, Don Mumbert. This
requirement was synopsized on 6 February 1995 as a Best-value
negotiated procurement. The specification has since been more fully
designed and shall be procured as a Invitation for Bid. This IFB is to
procure for the provision and installation of tube cable capable of
accepting air blown fiber optic strands. The successful bidder must be
capable of installing Sumitoma Electronic Industries (SEI)
manufactured tube cable capable of accepting air blown fiber optic
strands. Additionally, the successful bidder must be certified and
provide proof of certification as an acceptable installer by the
manufacturer at time of bid opening. SEI is the only known (to date)
manufacturer of air-blown fiber optic technology available. This
requirement is to provide and secure extensions to the fiber cable
plant and necessary incidental work that includes, but is not limited
to, trenching, excavating, and backfill, complete and ready for the
installation of a air blown fiber optic cable backbone in various
locations around the Naval Air Station. The work includes providing and
installing manholes, pedestal enclosures, direct burial tube cable,
tube cable in conduit, splice cases, network building services
entrances, junction boxes, underground rigid metallic conduit,
underground polyvinyl chloride (PVC) conduit, trenching, jack and
boring, the replacement of any road markings that need to be on the
road when making new patch with asphalt or cement, and incidental
related work. The required system must be capable of supporting
projects for engineering, manufacturing, and development of aircraft
and related subsystems for the next 20 years. Procurement and
installation of fiber and transmission medium is not a part of this
requirement. Due to the constantly changing mission requirements of the
Naval Air Warfare Center, Aircraft Division and the 53 other tenant
commands located at this base, the tubing system must allow the
flexibility to easily reconfigure and re-route air-blown fiber optic
cable. This tube cable system must be able to satisfy the following
requirements: (a) the incremental installation of the quantities and
types of air blown fiber needed to meet changing mission requirements,
(b) the ability to remove and reuse air blown fiber selectively with
no tensile stress on the fiber strands themselves, (c) the ability to
provide expedient emergency restoration without inducing additional
splice loss (attenuation) in a single step process, (d) the ability to
establish and change telecommunications routes quickly and easily
without disrupting main telecommunications services, and (e) the
ability to change fiber technology (single mode, multimode or new
capabilities) both selectively and incrementally. This requirement
shall be awarded as an Indefinite-Delivery Quantity type of contract
using competitive procedures. The estimated cost of construction is
between $1,000,000.00 and $5,000,000.00. The minimum guarantee will be
$600,000.00. A site visit is tentatively scheduled for 20 April 1995.
Do not call for additional technical information. Issuance of the
Invitation for Bid is tentatively scheduled for Wednesday, 5 April
1995. Based on the tentative issuance date all proposals must be
received in the Resident Officer in Charge of Construction (ROICC)
office by 2:00 p.m. 10 May 1995. There will be a $15.00 non-refundable
fee for the plans and specification/RFP. Checks should be made payable
to the Treasurer of the United States of America. Mail or deliver your
request for receiving plans and specifications to ROICC, Building 504,
Naval Air Warfare Center - Aircraft Division, Patuxent River, Maryland
20670-5504, Attn: Karl Hanson. Telephone and facsimile requests for
the RFP will not be honored. (082) Loren Data Corp. http://www.ld.com (SYN# 0148 19950329\Y-0001.SOL)
Y - Construction of Structures and Facilities Index Page
|
|