Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MARCH 13,1995 PSA#1301

Naval Air Warfare Center Training Systems Division, 12350 Research Parkway, Orlando, FL 32826-3224

58 -- SINGLE CHANNEL GROUND & AIRBORNE RADIOS (SINCGARS) DUE 032395 POC Ms. Linda Hursh, Contract Specialist, at (407)380-4058/Mr. William E. Kitterman, Contracting Officer, at (407)380-8171 The US Army Simulation, Training and Instrumentation Command (STRICOM) has a requirement for development, delivery, installation, test and integration of a Radio Monitor and Control subsystem consisting of the GFE SINCGARS/ICOM radios, as part of the National Training Center RMCS. This SINCGARS Monitor and Control Subsystem will support two-way digital communications between rotational units and the Core Instrumentation Subsystem (CIS). This subsystem must be capable of processing, time tagging, and storing radio traffic for incorporation into After Action Review and Take Home Packages (AAR/THP). Five remote facility sites using GFE microwave links and existing fiber optic transmission lines will be required to provide satisfactory signal coverage. The Operations Center, Building 988, will house the operator workstations. Tactical Air Control System (TACS) instrumentation personnel must be able to change frequencies, hopsets, crypto variables, and transmission sequence at the operations center. The RMCS upgrade must be able to monitor SINCGARS communications while it is in the ECCM mode (frequency- hopping). Expansion capabilities for additional engagement simulations areas which are not currently instrumented in land expansions at NTC and future projected tactical communications systems projected through the year 1999. Existing NTC-IS Computer Software Configuration Items were developed and documented in accordance with DOD-STD-2167A and MIL-STD-1815, Ada Program Language. A facility clearance will be required. Interested and qualified concerns are invited to submit written responses to this notice. Responses should include the following information: 1) Technical qualifications 2) Managerial qualifications (experience, facilities, staff) 3) Past performance on Government contracts of like or similar nature to include the Government Procuring Activity; contract number; dollar value; Procuring Contracting Officer name and telephone number; technical representative name and telephone number, narrative description of the requirement; actual tasks and percentage of work performed by your company to complete the contract requirement. Also indicate the size or status of your company based on SIC code 3663 (Size standard 750 employees). Responses should be submitted Ms. Linda Hursh at the address stated above no later than 17 March 1995. This advertisement does not constitute a request for a proposal; but is solely for the purpose of planning by surveying the market for qualified sources interested in the above requirement. (0068)

Loren Data Corp. http://www.ld.com (SYN# 0332 19950310\58-0008.SOL)


58 - Communication, Detection and Coherent Radiation Equipment Index Page